{"product_id":"mikroe-4292-oximeter-2-click-board-uk","title":"Oximeter 2 Click Board™","description":"\u003ch3\u003eHow Does The Oximeter 2 Click Board™ Work?\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eOximeter 2 Click Board™\u003c\/strong\u003e\u003c\/em\u003e is based on the ADPD144RI, a highly integrated, photometric front end optimized for photoplethysmography (PPG) detection of blood oxygenation from Analog Devices. It combines highly efficient, red and infrared LED emitters, with 660nm red and 880nm IR wavelengths, and a sensitive 4-channel photodiode with a custom ASIC that provides optical isolation between the integrated LED emitters and the detection photodiodes to improve the signal-to-noise ratio. It uses synchronous detection of optical pulses to enhance the rejection of ambient light in addition to low power consumption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"oximeter 2 Click Board™ inner\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.mikroe.com\/img\/images\/oximeter-2-click-inner.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eOximeter 2 Click Board™\u003c\/strong\u003e is designed for ultralow direct optical reflections, with independent AFE settings per channel and I2C control interface. The integrated LED emitters produce light pulses synchronous with the active sampling period of the AFE, which consisting of a programmable TIA, a band-pass filter, and an integrator. The processed analog signals are digitized by a 14-bit ADC and summed by the 20-bit burst accumulator. Four simultaneous sampling channels are matrixed into two independent time slots (one for each LED wavelength). An adjustable number of pulses per sample, accumulation, and averaging can be applied to multiple samples to increase the dynamic range to 27 bits.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eOximeter 2 Click Board™\u003c\/strong\u003e communicates with MCU using the standard I2C 2-Wire interface, with a typical clock frequency of 400kHz. A high-speed I2C interface allows data to be read from output registers directly or through a FIFO buffer. All register writes are single word only and require 16 bits of data. It also comes with a programmable interrupt line, labelled as INT and routed on the INT pin of the mikroBUS™ socket that simplifies timely data access. The ADPD144RI does not require a specific Power-Up sequence but requires a supply voltage of 1.8V in order to work properly. Therefore, a small regulating LDO is used, the ADP160 from Analog Devices, providing a 1.8V out of 3.3V mikroBUS™ rail.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eOximeter 2 Click Board™\u003c\/strong\u003e is designed to be operated only with a 3.3V logic voltage level. A proper logic voltage level conversion should be performed before the Click board™ is used with MCUs with different logic levels. However, MikroE equipped its users with a library that contains functions and an example code that can be used, as a reference, for further development.\u003c\/p\u003e\n\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eType\u003c\/td\u003e\n            \u003ctd\u003eBiometrics\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eApplications\u003c\/td\u003e\n            \u003ctd\u003eCan be used for applications such as optical pulse oximetry and health monitoring.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOn-board modules\u003c\/td\u003e\n            \u003ctd\u003eADPD144RI - highly integrated photometric front end optimized for photoplethysmography (PPG) detection of blood oxygenation from Analog Devices ADP160 - ultralow quiescent current linear regulator from Analog Devices\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eKey Features\u003c\/td\u003e\n            \u003ctd\u003eIntegrated optical components, fully integrated AFE, ADC, LED drivers, and timing core, low power consumption, designed for ultralow direct optical reflections, and more.\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface\u003c\/td\u003e\n            \u003ctd\u003eI2C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCompatibility\u003c\/td\u003e\n            \u003ctd\u003emikroBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eClick board size\u003c\/td\u003e\n            \u003ctd\u003eS (28.6 x 25.4 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePINOUT DIAGRAM\u003c\/h3\u003e\n\n\u003cp\u003eThis table shows how the pinout of the \u003cstrong\u003eOximeter 2 Click Board™\u003c\/strong\u003e corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).\u003c\/p\u003e\n\n\u003ctable width=\"549\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth colspan=\"4\"\u003e\u003cimg alt=\"Mikrobus logo.png\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\"\u003e\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eAN\u003c\/td\u003e\n            \u003ctd\u003ePWM\u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eRST\u003c\/td\u003e\n            \u003ctd\u003eINT\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eINT\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003eInterrupt\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eCS\u003c\/td\u003e\n            \u003ctd\u003eRX\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eSCK\u003c\/td\u003e\n            \u003ctd\u003eTX\u003c\/td\u003e\n            \u003ctd\u003e13\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eMISO\u003c\/td\u003e\n            \u003ctd\u003eSCL\u003c\/td\u003e\n            \u003ctd\u003e12\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCL\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Clock\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eMOSI\u003c\/td\u003e\n            \u003ctd\u003eSDA\u003c\/td\u003e\n            \u003ctd\u003e11\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDA\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eI2C Data\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e3.3V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n            \u003ctd\u003e5V\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eONBOARD SETTINGS AND INDICATORS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eLabel\u003c\/th\u003e\n            \u003cth\u003eName\u003c\/th\u003e\n            \u003cth\u003eDefault\u003c\/th\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLD1\u003c\/td\u003e\n            \u003ctd\u003ePWR\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ePower LED Indicator\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOXIMETER 2 CLICK ELECTRICAL SPECIFICATIONS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n            \u003cth\u003eMin\u003c\/th\u003e\n            \u003cth\u003eTyp\u003c\/th\u003e\n            \u003cth\u003eMax\u003c\/th\u003e\n            \u003cth\u003eUnit\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e3.3\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003eV\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRed LED Wavelenght\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e660\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003enm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInfrared LED Wavelenght\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e880\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003enm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eADC Resolution\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ebits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n            \u003ctd\u003e-40\u003c\/td\u003e\n            \u003ctd\u003e+25\u003c\/td\u003e\n            \u003ctd\u003e+85\u003c\/td\u003e\n            \u003ctd\u003e°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e \u003c\/h3\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":38028932448445,"sku":"MIKROE-4292","price":52.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-oximeter-2-click-board-30237771727037.jpg?v=1685194680","url":"https:\/\/thedebugstore.com\/es\/products\/mikroe-4292-oximeter-2-click-board-uk","provider":"Debug Store","version":"1.0","type":"link"}