{"product_id":"lineeye-si-60-e-interface-converter-lan-rs-232c-uk","title":"Lineeye SI-60-E LAN to RS-232C Interface Converter","description":"\u003ch5\u003e■Block Chart\u003c\/h5\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/si60e_block.gif\" src=\"https:\/\/www.lineeye.com\/img\/si60e_block.gif\"\u003e\u003c\/p\u003e\n\n\u003ch6\u003eRS-232C connector pin arrangement\u003c\/h6\u003e\n\n\u003ctable cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth rowspan=\"2\"\u003ePin \u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/th\u003e\n            \u003cth rowspan=\"2\"\u003eSignal\u003c\/th\u003e\n            \u003cth colspan=\"2\"\u003eI\/O \u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth\u003eDTE\u003c\/th\u003e\n            \u003cth\u003eDCE\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eFG\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eSD\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eRD\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eRS (RTS)\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eCS (CTS)\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eOut\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eDR (DSR)  \u003csup\u003e*3\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e+DC IN \u003csup\u003e*4\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e20\u003c\/td\u003e\n            \u003ctd\u003eER (DTR)  \u003csup\u003e*3\u003c\/sup\u003e\n\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n            \u003ctd\u003eIn\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e*1: Pins not listed here are not connected. *2: The DTE\/DCE selector switch changes In and Out. *3: Pins 6 and 20 are internally connected in this unit. *4: Power can be supplied from this pin when the AC adapter is not used.\u003c\/p\u003e\n\n\u003ch5\u003e■Example of SI-60 Connection\u003c\/h5\u003e\n\n\u003cp\u003eAttached software (COM port Redirector \u003csup\u003eTM \u003c\/sup\u003e) controls the RS-232C device as if it is connecting directly to the serial port (COM1 to n) of PC. This reduces the modification of communication programs. Also, you can transmit\/receive RS-232C serial data directly using the TCP\/IP socket communication method.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_connect_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_connect_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Locate RS-232C devices to further place using LAN cable\u003c\/h5\u003e\n\n\u003cp\u003e2sets of SI-60 makes it possible to locate the RS-232C devices in the far place using LAN cable. One set of SI-60 has to be in Server mode (or Server and Client mode) and the other one has to be in Client mode (or Server and Client) mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_extension_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_RS232C_extension_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Connection with LINEEYE analyzer\u003c\/h5\u003e\n\n\u003cp\u003eBy connecting the LINEEYE analyzers to LAN (Ethernet) using SI-60, you can analyze the data on a PC in the office far from the workplace in real time, continuously measuring the data between the device A and B.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-60_protcolanalyzer_320.gif\" src=\"https:\/\/www.lineeye.com\/img\/SI-60_protcolanalyzer_320.gif\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■Space-saving\u003c\/h5\u003e\n\n\u003cp\u003eAble to install the device on the 35mm DIN rail using Optional DIN plate (SI-DIN70), and to install it on the wall using the optional wall bracket (SI-WM1).\u003c\/p\u003e\n\n\u003cp\u003eDIN Rail Installation Example\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/si6060f_din.jpg\" src=\"https:\/\/www.lineeye.com\/img\/si6060f_din.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eOptional \"Metal Fitting for Wall\"\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SI-65_wallmount.jpg\" src=\"https:\/\/www.lineeye.com\/img\/SI-65_wallmount.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003e■2 kinds of power input\u003c\/h5\u003e\n\n\u003cp\u003eAble to supply the power from attached AC adapter. Supplying power from Dsub 9pin of device via RS-232C device eliminates the use of AC adapter and saves space.\u003c\/p\u003e\n\n\u003ch5\u003e■A Useful Tool for Multiple Operation\u003c\/h5\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eSILANIOinit is a configuration tool for LINEEYE products embedded WiPort-NR. It is useful and saves time to rewrite the WiPort-NR configuration file (Setup Record) .\u003c\/p\u003e\n\n\u003ch6\u003e［ Functions ］\u003c\/h6\u003e\n\n\u003cul\u003e\n    \u003cli\u003eSearches the device on the Network. Displays the MAC address.\u003c\/li\u003e\n    \u003cli\u003eReads and saves the configuration (set-up record) of converter.\u003c\/li\u003e\n    \u003cli\u003eWrites to the set-up record of selected converter.\u003c\/li\u003e\n    \u003cli\u003eSets the IP address of selected converter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConfiguration tool (SILANIOinit)\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.lineeye.com\/img\/SILANIOinit_104_350.gif\" src=\"https:\/\/www.lineeye.com\/img\/SILANIOinit_104_350.gif\"\u003e\u003c\/p\u003e","brand":"Lineeye Co Ltd","offers":[{"title":"Default Title","offer_id":37768482848957,"sku":"SI-60-E","price":270.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/lineeye-co-ltd-protocol-analyser-accessory-lineeye-si-60-e-lan-to-rs-232c-interface-converter-36133953667295.jpg?v=1685079289","url":"https:\/\/thedebugstore.com\/es\/products\/lineeye-si-60-e-interface-converter-lan-rs-232c-uk","provider":"Debug Store","version":"1.0","type":"link"}