{"title":"Picotest Signal Injectors","description":"\u003cp\u003ePicotest Signal Injectors, available from The Debug Store, are essential tools for power supply analysis and testing. These high-quality devices enable precise measurements of power integrity, PSRR, and input impedance. Designed by industry expert Steve Sandler, Picotest injectors offer wide bandwidth, low noise, and compatibility with various test equipment, enhancing power supply design and troubleshooting capabilities.\u003c\/p\u003e","products":[{"product_id":"picotest-j2100a-injection-transformer-1hz-5mhz-uk","title":"Picotest J2100A Injection Transformer 1Hz - 5MHz","description":"\u003cp\u003eThe injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.\u003c\/p\u003e\n\n\u003cp\u003eThe usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.\u003c\/p\u003e\n\n\u003cp\u003eThe bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2100a_spec(1).jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444006623,"sku":"J2100A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2100a-injection-transformer-1hz-5mhz-36974284865759.jpg?v=1685074259"},{"product_id":"picotest-j2101a-injection-transformer-10hz-45mhz-uk","title":"Picotest J2101A Wideband Injection Transformer 10Hz–45MHz","description":"\u003ch1\u003eProduct Information\u003c\/h1\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eJ2101A Injection Transformer\u003c\/strong\u003e is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.\u003c\/p\u003e\n\n\u003cp\u003eThe usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element.\u003c\/p\u003e\n\n\u003cp\u003eThe bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2101a_spec.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\n\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" bordercolor=\"#b0d5ff\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#b0d5ff\" colspan=\"2\"\u003ePerformance at -10dBm input level\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\" width=\"50%\"\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDCR\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRatio\u003c\/td\u003e\n            \u003ctd\u003e1:1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTermination Impedance\u003c\/td\u003e\n            \u003ctd\u003e5 Ohms\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eUsable Bandwidth\u003c\/td\u003e\n            \u003ctd\u003e10Hz - 45MHz (Terminated into 5 Ohms)\u003cbr\u003e\n            60Hz - 45MHz (Terminated into 50 Ohms)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n            \u003ctd\u003e600V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIsolation Capacitance\u003c\/td\u003e\n            \u003ctd\u003e150pF@1KHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDC Current\u003c\/td\u003e\n            \u003ctd\u003e10mA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTemperature Range\u003c\/td\u003e\n            \u003ctd\u003e0 ~ 50°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n            \u003ctd\u003e6000 Ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eNote: The upper end of the bandwidth is heavily dependent on the interconnect between the Injector and the DUT.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688444432607,"sku":"J2101A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-j2101a-injection-transformer-10hz-45mhz-36974338179295.jpg?v=1685074257"},{"product_id":"picotest-j2102b-common-mode-transformer-uk","title":"Transformador de modo común Picotest J2102B","description":"\u003cp\u003eEl método más sencillo y eficaz para eliminar un bucle de masa es añadir a la medida un transformador de modo común de banda ancha, como el transformador de modo común Picotest J2102B. Para una medida de PDN de baja impedancia, el transformador debe tener un ancho de banda muy amplio, bajas pérdidas y un acoplamiento estrecho; de lo contrario, los resultados no serán precisos en todo el rango de frecuencias medido. También es importante mantener la impedancia de línea de transmisión de 50 Ohm a través del transformador, algo que el J2102B consigue con facilidad. El J2102B combinado con el cable PDN de Picotest es la mejor solución general. El J2113A es una opción mejor si necesita medir por debajo de 3kHz y con una frecuencia máxima inferior a 500kHz. Debido a su CMRR limitado, no se recomienda el J2113A por debajo de 1mOhm. Si se utilizan otros cables con cualquiera de las dos soluciones, la precisión de la medida puede degradarse de forma significativa por debajo de 1MHz, debido a la elevada resistencia de la malla del cable y a su escaso aislamiento.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"BNC (J2102B-BNC)","offer_id":42691042345183,"sku":"J2102B-BNC","price":830.5,"currency_code":"GBP","in_stock":true},{"title":"N (J2102B-N)","offer_id":42691042377951,"sku":"J2102B-N","price":830.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-bnc-picotest-j2102b-common-mode-transformer-36974512701663.jpg?v=1685074248"},{"product_id":"picotest-j2110a-solid-state-injector-uk","title":"Picotest J2110A Solid State Injector","description":"\u003cp align=\"justify\"\u003eWhile it is possible to obtain high quality injection transformers with bandwidths as wide as 1Hz to 5MHz or more, in some cases this is still insufficient for some tests. For example a typical heater control loop might have a bandwidth of less than 1Hz while some linear regulators and opamp circuits can have bandwidths of up to 100MHz or in some cases even higher. For these applications, a \u003cem\u003e\u003cstrong\u003eSolid State Injector\u003c\/strong\u003e\u003c\/em\u003e can provide the necessary bandwidth. A solid state injector can perform at DC, while the upper frequency limit is dictated by the components selected and the printed circuit board material and layout. It is possible to obtain a solid state injector with a working range of DC – 200MHz, though above 50MHz the interconnection between the injector and the circuit being tested can become quite critical. It is essential that ripple from the injector power supply does not dramatically degrade the dynamic range or the signal to noise ratio of the measurement. The resulting plots are often much cleaner when using a solid state injector than with a transformer injector.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eThe selection of a valid injection point in the circuit is more critical when using a solid state injector than with the transformer injector. The solid state injector presents an infinite impedance between the points of injection. In order to provide correct results one side of the measurement must present a much higher impedance than the other side. In a typical power supply control loop, the voltage sense divider is generally a good injection point, since the output impedance of the power supply is very low compared with the impedance of the voltage sense divider.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eSolid State Injector\u003c\/strong\u003e has a limitation in the operating voltage, with the majority limited to 10V or 12V. This is not the amplitude of the injection signal, but the peak value (positive or negative) of the signal operating voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.picotest.com\/highslide\/graphics\/outlines\/J2110A_labelsB.gif\" onclick=\"return hs.expand(this, config1 )\" title=\"J2110A Solid State Injector\"\u003e\u003cimg alt=\"J2110A Solid State Injector\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/www.picotest.com\/highslide\/graphics\/outlines\/J2110A_labels.gif\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688445219039,"sku":"J2110A","price":1590.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2110a-solid-state-injector-36974954840287.jpg?v=1685073711"},{"product_id":"picotest-j2112a-high-current-injector","title":"Picotest J2112A High Current Injector","description":"\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\n\u003cul\u003e\n    \u003cli\u003eHigh PSRR Low Noise Regulator with Universal input\u003c\/li\u003e\n    \u003cli\u003eFast Transient Load Stepping up to 1Amp\u003c\/li\u003e\n    \u003cli\u003e20nSec typ rise and fall time\u003c\/li\u003e\n    \u003cli\u003eDC-40MHz usable range (interconnection dependent)\u003c\/li\u003e\n    \u003cli\u003eMeasures Non-invasive phase margin, Output impedance, reverse transfer, crosstalk, input filter stability\u003c\/li\u003e\n    \u003cli\u003eWorks with positive voltage sources\u003c\/li\u003e\n    \u003cli\u003eBuilt in offset for use with Network Analyzer\u003c\/li\u003e\n    \u003cli\u003ePrecision current monitor with 50 Ohm output\u003c\/li\u003e\n    \u003cli\u003eWorks with any manufacturer's AWG, Function generator and network analyzer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe \u003cem\u003e\u003cstrong\u003eJ2112A Current Injector\u003c\/strong\u003e\u003c\/em\u003e is an extremely versatile tool addition to the Picotest Signal Injector line-up. Coupled with the G5100A AWG, or other equivalent function generator, it is capable of performing small and large-signal load steps up to 40MHz, with up to 20ns rise\/fall times, and with currents up to 1amp. Rise and fall times can be controlled and arbitrary waveforms can be used to drive the injector producing load current profiles of virtually any characteristic pattern. This is ideal for emulating all types of load conditions, including high speed digital circuit loading, battery discharge profiles, or spontaneous current spikes.\u003c\/p\u003e\n\n\u003cp\u003eWhen coupled with a network analyzer, the Current Injector can be used to measure the output impedance of all types of circuits and systems including power supplies, voltage regulators, power buses, and batteries. It can be used to NON-INVASIVELY measure the stability of a combined input filter \/negative resistance of a switching power supply or the phase margin of a linear or switching regulator WITHOUT the need to break the control loop.\u003c\/p\u003e\n\n\u003cp\u003eIt also supports applications in the measurement and extraction of transistor data, including current gain, Ft, and many other dynamic performance parameters. In RF and instrumentation circuits it can be used to provide constant current biasing for class A amplifiers and buffers.\u003c\/p\u003e\n\n\u003ch3 aling=\"justify\"\u003eThe Ultimate Controllable Current Source\u003c\/h3\u003e\n\n\u003cp aling=\"justify\"\u003eThe controlling input is an arbitrary user controlled DC+AC signal that can be taken from either a signal generator or network analyzer. A built-in bidirectional bias current enables Class A operation for use with network analyzers.\u003c\/p\u003e\n\n\u003cp aling=\"justify\"\u003eThe output current is reduced 40dB from the input signal, resulting in 10mA\/V scaling. The current monitor output port is designed to be terminated into 50 Ohms and can be used with the network analyzer, an oscilloscope or a DMM to monitor the output current of the injector on a 1A\/V scale.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688447348959,"sku":"J2112A","price":1908.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2112a-high-current-injector-36985290621151.jpg?v=1684979399"},{"product_id":"picotest-j2120a-line-injector-uk","title":"Inyector de línea Picotest J2120A | Pruebas de PSRR de 10 Hz a 10 MHz","description":"\u003ctable bgcolor=\"#FFFFFF\" border=\"1\" bordercolor=\"#b0d5ff\" cellpadding=\"5\" cellspacing=\"0\" width=\"100%\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd bgcolor=\"#dfeeff\" colspan=\"2\"\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\"\u003e\u003cstrong\u003eTípico\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd bgcolor=\"#dfeeff\"\u003e\u003cstrong\u003eUnidades\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eTensión máxima de entrada CC\u003c\/td\u003e\n            \u003ctd\u003e50\u003c\/td\u003e\n            \u003ctd\u003eVDC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eCorriente máxima en régimen continuo\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eCaída de tensión máxima\u003c\/td\u003e\n            \u003ctd\u003e3.25\u003c\/td\u003e\n            \u003ctd\u003e\n            \u003cp\u003eVDC\u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eImpedancia de entrada de modulación\u003c\/td\u003e\n            \u003ctd\u003e10K\u003c\/td\u003e\n            \u003ctd\u003eohmios\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eRespuesta en frecuencia a 3 dB\u003c\/td\u003e\n            \u003ctd\u003e15-5M\u003c\/td\u003e\n            \u003ctd\u003eHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eRespuesta en frecuencia útil\u003c\/td\u003e\n            \u003ctd\u003e10-10M\u003c\/td\u003e\n            \u003ctd\u003eHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eSeñal de inyección recomendada\u003c\/td\u003e\n            \u003ctd\u003e-20 - 0\u003c\/td\u003e\n            \u003ctd\u003edBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003eRango de temperatura\u003c\/td\u003e\n            \u003ctd\u003e0-50\u003c\/td\u003e\n            \u003ctd\u003eC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eAltitud máxima\u003c\/td\u003e\n            \u003ctd\u003e6000\u003c\/td\u003e\n            \u003ctd\u003epies\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" valign=\"top\"\u003eTensión máxima absoluta\u003c\/td\u003e\n            \u003ctd\u003e\u0026lt; 50V (CC + CA)\u003c\/td\u003e\n            \u003ctd\u003e \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eJ2120A es el inyector de menor impedancia del mercado y su impedancia puede aproximarse mediante la siguiente relación con la corriente de funcionamiento.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"49\" src=\"https:\/\/www.picotest.com\/images\/j2120a-low-impedance-formula.png\" width=\"317\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eO aproximadamente 180 mOhm a 1 A\u003cbr\u003e\n\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"37\" src=\"https:\/\/www.picotest.com\/images\/safety-triangle-50.png\" width=\"50\"\u003ePrecaución: para evitar daños en el equipo, lesiones graves o incluso la muerte, asegúrese de respetar en todo momento los valores máximos absolutos y de no superarlos.\u003cbr\u003e\nNota sobre EMI: superar 0 dBm puede hacer que la unidad supere los límites de EMI de la marca CE.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688448823519,"sku":"J2120A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2120a-line-injector-36985135792351.jpg?v=1684979743"},{"product_id":"picotest-j2123a-negative-voltage-psrr-injector","title":"Picotest J2123A Negative Voltage PSRR Injector - 10Hz-50MHz Line Injector","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional Negative Voltage PSRR Testing Made Simple\u003c\/h2\u003e\n\u003cp\u003eThe Picotest J2123A Negative Voltage PSRR Injector transforms complex power supply testing into straightforward measurements. Specifically designed for negative voltage systems, this passive line injector enables accurate Power Supply Rejection Ratio (PSRR), Power Supply Modulation Ratio (PSMR), and Common-Mode Rejection Ratio (CMRR) measurements across a wide frequency range.\u003c\/p\u003e\n\u003ch3\u003eKey Applications\u003c\/h3\u003e \u003cp\u003eEssential for testing negative voltage regulators, audio amplifiers, and precision reference circuits. The J2123A excels in applications requiring low-noise modulation of negative DC power sources, making it indispensable for engineers working with dual-supply systems or negative voltage rails.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e-30VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e3VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e3dB Frequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz-20MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUseable Frequency Response\u003c\/td\u003e\n\u003ctd\u003e10Hz-50MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRecommended Injection Signal\u003c\/td\u003e\n\u003ctd\u003e-20dBm to 10dBm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0-50°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e\n\u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"aside\"\u003e \u003ch4\u003eCritical Polarity Warning\u003c\/h4\u003e \u003cp\u003eThe J2123A contains a polarised internal capacitor and will be damaged if input voltage is reversed. In negative voltage systems, the return jack (ground\/0V) must be more positive than the MINUS SUPPLY connection.\u003c\/p\u003e \u003c\/div\u003e\n\u003cp\u003eConnect your negative power supply to the J2123A input terminals with correct polarity: ground (return) to the positive terminal, negative voltage to the negative terminal. Connect the modulation source (such as a Bode 100 or network analyser) to the OSC input. The J2123A output connects directly to your device under test.\u003c\/p\u003e\n\u003ch3\u003eMeasurement Setup\u003c\/h3\u003e \u003cdiv class=\"imgph\"\u003eTypical PSRR measurement setup diagram\u003c\/div\u003e\n\u003cp\u003eFor single-supply PSRR measurements, connect Channel 1 of your analyser to the J2123A input, Channel 2 to the output. The ratio measurement directly provides PSRR data. For dual-supply audio amplifier testing, use the J2123A in conjunction with a J2120A for comprehensive positive and negative rail modulation.\u003c\/p\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e \u003cp\u003eVoltage drop and output resistance follow the relationship: V(I) = 2.312 × I^0.055 + 0.090I, where current is in amperes. This passive design ensures optimum performance with minimal noise injection while maintaining wide bandwidth capability.\u003c\/p\u003e\n\u003cdiv class=\"spec-note\"\u003e \u003cp\u003eRemote sensing capability allows compensation for the line injector's voltage drop when using laboratory power supplies with adequate compliance range.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688449839327,"sku":"J2123A","price":632.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-j2123a-picotest-j2123a-negative-voltage-psrr-injector-precision-power-supply-testing-tool-72450246312311.png?v=1733794124"},{"product_id":"picotest-j2130a-dc-bias-injector-uk","title":"Picotest J2130A DC Bias Injector","description":"\u003cp\u003eWhen using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688450298079,"sku":"J2130A","price":550.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2130a-dc-bias-injector-36984605114591.jpg?v=1684968413"},{"product_id":"picotest-j2140a-attenuator","title":"Picotest J2140A Attenuator","description":"\u003cp align=\"justify\"\u003eThere are two common uses for attenuators when used in conjunction with the network analyzer. One is to attenuate the oscillator source signal. While this may seem odd, one of the most common errors in analyzer measurements is using a source signal that is too large. Even though the analyzer allows setting of the signal output amplitude, the lowest setting is often too high to allow an accurate small-signal measurement to be made. The correct amplitude is the smallest amplitude that exceeds the noise floor.\u003c\/p\u003e\n\n\u003cp align=\"justify\"\u003eAttenuators are also useful for improving the dynamic range of the measurement. In some cases, as in measuring the open loop gain of an opamp as one example, the low frequency loop gain will be extremely large (100dB or more is not uncommon). Attenuating the output signal increases the effective range of the measurement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" data-entity-type=\"\" data-entity-uuid=\"\" src=\"https:\/\/web.hocom.tw\/ckfinder\/connector?command=Proxy\u0026amp;type=Images\u0026amp;currentFolder=%2f\u0026amp;fileName=j2140a_spec.gif\"\u003e\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688450756831,"sku":"J2140A","price":291.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-picotest-j2140a-attenuator-36984647483615.jpg?v=1684980106"},{"product_id":"picotest-j2161a-2-way-wideband-active-splitter","title":"Picotest J2161A 2-Way Wideband Active Splitter","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688451608799,"sku":"J2161A","price":1925.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-picotest-j2161a-2-way-wideband-active-splitter-36984833016031.jpg?v=1684979926"},{"product_id":"picotest-j2170b-high-psrr-power-adapter","title":"Picotest J2171A High PSRR Regulated Adapter","description":"\u003cp\u003eWhile there are many off-the-shelf power supplies available that can provide a universal input voltage and 12V output voltage, they do not provide the same performance as the J2170B. Most switching regulators produce significant ripple at and above 100kHz. This ripple passes through the PSRR of the internal opamps, reducing the noise floor. While this may work in many applications, it is less than ideal. Typical switching power supplies and even typical linear regulators have a high output impedance at 40MHz, due to the ESL of the output capacitors and the nature of the control loop.The \u003cstrong\u003ePicotest J2170B\u003c\/strong\u003e uses a discrete design approach, offering very low output impedance, stable performance with large ceramic decoupling capacitors and ultra high PSRR compared with typical off-the-shelf devices. To maintain a good noise floor for various measurements, the power supply must have very low noise.\u003c\/p\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688451707103,"sku":"J2170B","price":275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-power-supply-picotest-j2170b-high-psrr-power-supply-adapter-36975355625695.jpg?v=1685073182"},{"product_id":"picotest-injector-bundle-1-uk","title":"Picotest Injector Bundle #1","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489455839,"sku":"INJB01","price":4620.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-1-36974070759647.jpg?v=1685074610"},{"product_id":"picotest-injb02-injector-bundle-2-uk","title":"Picotest Injector Bundle #2","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489750751,"sku":"INJB02","price":3905.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-2-36974035042527.jpg?v=1685074613"},{"product_id":"picotest-injb03-injector-bundle-3-uk","title":"Picotest Injector Bundle #3","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688489783519,"sku":"INJB03","price":2695.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-3-36973977764063.jpg?v=1685074619"},{"product_id":"picotest-injb05-injector-bundle-5-uk","title":"Picotest Injector Bundle #5","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42688490012895,"sku":"INJB05","price":4950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-injector-bundle-5-36969791586527.jpg?v=1685080007"},{"product_id":"picotest-j2121a-line-injector","title":"Picotest J2121A High Power Line Injector - 400V\/20A","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional High-Power PSRR Testing for Military and Satellite Applications\u003c\/h2\u003e \u003cp\u003eThe Picotest J2121A High Power Line Injector represents the pinnacle of power supply rejection ratio (PSRR) testing capability, engineered specifically for high-voltage, high-current applications in military and satellite power systems. This advanced test instrument enables engineers to inject precise modulation signals into DC power lines whilst maintaining electrical isolation and measurement accuracy across a wide frequency spectrum.\u003c\/p\u003e \u003ch3\u003eHow PSRR Measurement Works\u003c\/h3\u003e \u003cp\u003ePower Supply Rejection Ratio testing quantifies how effectively a power supply or regulator attenuates unwanted AC signals on its input from appearing at the output. The J2121A modulates the input DC supply voltage using a network analyser source signal, creating controlled disturbances that simulate real-world noise conditions. Engineers measure both input and output signals to calculate the rejection ratio as 20×log(V\u003csub\u003einput\u003c\/sub\u003e\/V\u003csub\u003eoutput\u003c\/sub\u003e).\u003c\/p\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eWhat Makes Line Injectors Essential:\u003c\/strong\u003e Unlike current probes or injection transformers, line injectors can handle significant DC currents whilst providing galvanic isolation between measurement equipment and high-voltage systems. \u003c\/div\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cdiv class=\"imgph\"\u003eJ2121A connection diagram showing VNA, power supply, and DUT connections\u003c\/div\u003e \u003ch4\u003eBasic PSRR Measurement Setup:\u003c\/h4\u003e \u003col\u003e \u003cli\u003e\n\u003cstrong\u003ePower Connections:\u003c\/strong\u003e Connect J2171A power supply to J2121A proprietary power connector\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e Connect DC supply positive to red banana jack (+), negative to black banana jack (-)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSignal Injection:\u003c\/strong\u003e Connect VNA source output to BNC modulation input\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDUT Connection:\u003c\/strong\u003e Connect J2121A output banana jacks to device under test input\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCurrent Monitoring:\u003c\/strong\u003e Connect current monitor BNC output to VNA channel 1\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e Connect high-impedance probe to DUT output for VNA channel 2\u003c\/li\u003e \u003c\/ol\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eConnection Point\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eDC Input +\/-\u003c\/td\u003e\n\u003ctd\u003e4mm Banana Jacks (Female)\u003c\/td\u003e\n\u003ctd\u003e400VDC @ 20A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModulation Input\u003c\/td\u003e\n\u003ctd\u003e50Ω BNC\u003c\/td\u003e\n\u003ctd\u003e6dBm Recommended Signal Level\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent Monitor\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003ctd\u003e100mV\/A Scale Factor\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eProprietary (J2171A)\u003c\/td\u003e\n\u003ctd\u003e200mA Low-Noise Supply\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ch3\u003eDC-DC Converter Input Impedance Testing\u003c\/h3\u003e \u003cp\u003eBeyond PSRR measurements, the J2121A excels at characterising DC-DC converter input impedance—a critical parameter for avoiding negative resistance instabilities in power distribution networks. The integrated current monitor eliminates the need for external current probes, streamlining the measurement process whilst maintaining accuracy.\u003c\/p\u003e \u003cpre\u003e\u003ccode\u003e\/\/ Example calculation for input impedance Z_input = V_modulation \/ I_monitor \/\/ Where I_monitor = V_current_out \/ 100mV\/A \/\/ Frequency sweep from 100Hz to 1MHz\u003c\/code\u003e\u003c\/pre\u003e \u003cdiv class=\"callout\"\u003e \u003cstrong\u003eProfessional Tip:\u003c\/strong\u003e Always use the included 1Ω calibration fixture to verify measurement accuracy before conducting critical tests. This ensures traceability and validates the complete measurement chain. \u003c\/div\u003e \u003ch3\u003eComparison with J2120A Line Injector\u003c\/h3\u003e \u003cp\u003eThe J2121A addresses applications where the popular J2120A's 50V\/5A limits prove insufficient. Key advantages include 8× higher voltage capability, 4× higher current rating, active regulation maintaining constant 750mV voltage drop, and integrated Hall-effect current monitoring that eliminates external probe requirements.\u003c\/p\u003e \u003c\/section\u003e","brand":"Picotest","offers":[{"title":"Default Title","offer_id":42695069237471,"sku":"J2121A","price":2420.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/picotest-corp-injector-picotest-j2121a-high-power-line-injector-36984705581279.jpg?v=1684979941"},{"product_id":"picotest-j2103a-power-stage-isolator","title":"Picotest J2103A Power Stage Isolator","description":"","brand":"Picotest","offers":[{"title":"Default Title","offer_id":44442976157919,"sku":"J2103A","price":795.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-corp-j2103a-40644861067487.jpg?v=1697976477"},{"product_id":"picotest-j2180a-ultra-low-noise-preamplifer-uk","title":"Picotest J2180A Ultra Low Noise Amplifier","description":"","brand":"Picotest","offers":[{"title":"20Hz to 100MHz (J2180A-20)","offer_id":44443046904031,"sku":"J2180A-20","price":2150.0,"currency_code":"GBP","in_stock":true},{"title":"0.1Hz to 100MHz (J2180A)","offer_id":44443046936799,"sku":"J2180A","price":1895.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-corp-j2180a-picotest-ultra-low-noise-preamplifer-j2180a-debug-store-uk-40645069832415.jpg?v=1697984574"},{"product_id":"injb03-j2102b-p21b02-trn002-j2114a-3dpp-200-2","title":"Picotest Power Integrity Station Bundle without Bode 100 VNA","description":null,"brand":"Picotest","offers":[{"title":"Default Title","offer_id":54776794153335,"sku":"PWR100B","price":10500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/picotest-pwr100b-picotest-power-integrity-station-bundle-without-bode-100-vna-1193985451.jpg?v=1758545348"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/tr-picotest-injector-kit.png?v=1733761913","url":"https:\/\/thedebugstore.com\/es\/collections\/picotest-signal-injectors.oembed","provider":"Debug Store","version":"1.0","type":"link"}