{"title":"OMICRON-Lab","description":"\u003cp\u003eOmicron Lab is a division of OMICRON electronics that specializes in high-precision test and measurement equipment for electronic design engineers. They offer vector network analyzers, impedance analyzers, and other tools for RF and high-speed digital applications. Omicron Lab provides solutions for industries like telecommunications, automotive, aerospace, and research institutions worldwide, focusing on accurate and efficient testing capabilities.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"omicron-lab-bode-100-vector-network-analyser-uk","title":"Analizador de redes vectorial (VNA) OMICRON Lab Bode 100","description":"\u003c!-- Introduction --\u003e\n\u003cheader\u003e\n\u003ch2\u003ePaquetes:\u003c\/h2\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e- Instrumento Bode 100 con certificado de calibración\u003cbr\u003e\n- Bode Analyzer Suite - Software para PC con Windows - en DVD\u003cbr\u003e\n- Guía de inicio rápido impresa\u003cbr\u003e\n- Adaptador de alimentación de CA de rango amplio (18 W)\u003cbr\u003e\n- Cable USB-A a USB-B\u003cbr\u003e\n- Adaptador BNC recto (h-h)\u003cbr\u003e\n- Conexión BNC en T (h-h-h)\u003cbr\u003e\n- Carga BNC de 50 Ω (m)\u003cbr\u003e\n- Cortocircuito BNC (m)\u003cbr\u003e\n- 4x cable BNC de 0.5m (m-m)\u003cbr\u003e\n- Objetos de prueba en PCB (filtro de cuarzo y filtro de FI)\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eBasic\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e- Instrumento Bode 100 con certificado de calibración\u003cbr\u003e\n- Bode Analyzer Suite - Software para PC con Windows - en DVD\u003cbr\u003e\n- Guía de inicio rápido impresa\u003cbr\u003e\n- Adaptador de alimentación de CA de rango amplio (18 W)\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEducational\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e1x Bode 100 - Analizador de redes vectorial\u003cbr\u003e\n1x B-WIT 100 - Transformador de inyección de banda ancha\u003cbr\u003e\n1x B-WIC - Accesorio de prueba de impedancia\u003cbr\u003e\n2x PML 111O sonda pasiva de alta impedancia 10:1\u003cbr\u003e\n1x Maletín de transporte para Bode 100 \/ 500\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003e*Solo para clientes del ámbito educativo\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eEl Bode 100 es la solución profesional para realizar mediciones de barrido en frecuencia precisas y rápidas de 1 Hz a 50 MHz, imprescindibles en el diseño de fuentes de alimentación y para un funcionamiento estable del lazo.\u003c\/p\u003e\n\u003c\/header\u003e\n\u003c!-- Overview --\u003e\n\n\u003csection\u003e\n\u003cdiv class=\"overview\"\u003e\n\u003cp\u003eEl hardware dedicado ofrece un barrido rápido junto con un rechazo de ruido excepcional, lo que permite mediciones de alto rango dinámico no solo en componentes pasivos y reguladores lineales, sino también en convertidores conmutados.\u003c\/p\u003e\n\n\u003cp\u003eJunto con Bode Analyzer Suite, el Bode 100 es una opción muy adecuada para equipar su laboratorio de diseño.\u003c\/p\u003e\n\n\u003cp\u003ePermite analizar sistemas, lazos de control, componentes electrónicos y mucho más con una excelente relación calidad-precio. El Bode 100 no solo ofrece análisis de respuesta en frecuencia (FRA), sino también análisis de redes vectorial (VNA) y funciones de analizador de impedancia. Equípese y forme parte de los usuarios satisfechos de Bode.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e\u003cimg alt=\"Medición de la respuesta en frecuencia y en fase\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"345\" src=\"https:\/\/www.omicron-lab.com\/fileadmin\/_processed_\/1\/e\/csm_Frequency_Response_freigestellt_471351adc3.jpg\" width=\"500\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Power Electronics Design \u0026 Analysis --\u003e\n\n\u003cheader\u003e\n\u003ch2\u003eDiseño y análisis de electrónica de potencia\u003c\/h2\u003e\n\u003c\/header\u003e\n\n\u003cp\u003eMedir una función de transferencia mediante análisis de respuesta en frecuencia es un método muy eficaz para diseñar sistemas electrónicos, como compensadores para convertidores conmutados o reguladores de tensión. El hardware y el software del Bode 100 están optimizados para mediciones de lazo y de impedancia, análisis de estabilidad y mucho más. A continuación se describen las principales aplicaciones en electrónica de potencia en las que el Bode 100 puede ayudarle en su proceso de diseño:\u003c\/p\u003e\n\u003c!-- Loop Gain --\u003e\n\n\u003csection\u003e\n\u003ch3\u003eGanancia de lazo (margen de fase y margen de ganancia)\u003c\/h3\u003e\n\n\u003cdiv class=\"loop-gain\"\u003e\n\u003cp\u003eEs uno de los pasos más importantes al caracterizar o diseñar el lazo de control de un convertidor de potencia. El Bode 100 ofrece un alto rechazo de banda lateral y un alto rango dinámico con una velocidad de medición muy elevada. Realice mediciones de respuesta del lazo en segundos para caracterizar por completo su lazo de control en distintos puntos y condiciones de funcionamiento. Compruebe lo rápidas y sencillas que pueden ser las mediciones de estabilidad y consulte nuestra nota de aplicación.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e\u003cimg alt=\"Ganancia de lazo (margen de fase y margen de ganancia)\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"166\" src=\"https:\/\/www.omicron-lab.com\/fileadmin\/_processed_\/1\/8\/csm_LoopGainSchematic_b6141d84ab.png\" width=\"500\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Companion Power Supply Design Software --\u003e\n\n\u003cheader\u003e\n\u003ch3\u003eSoftware complementario de diseño de fuentes de alimentación para Bode 100\u003c\/h3\u003e\n\u003c\/header\u003e\n\n\u003cp\u003eGracias a su perfecta integración con el software de diseño automatizado de fuentes de alimentación WDS de Biricha, el Bode 100 ayuda a reducir considerablemente el tiempo y el coste de desarrollo de sus fuentes de alimentación. Utilice WDS para diseñar en minutos fuentes de alimentación estables con control analógico y digital.\u003c\/p\u003e\n\n\u003cp\u003eEl software de diseño de fuentes de alimentación WDS de Biricha simplifica el diseño e incluye la colocación automática de polos y ceros para una compensación óptima. Además de las topologías incluidas, como Buck, Boost, Buck-Boost, Flyback, SEPIC, puente completo, medio puente y convertidores forward, WDS permite ahora importar desde el Bode 100 una función de transferencia de planta medida para diseñar un compensador estable. Vea este seminario web del Dr. Ali Shirsavar para saber más sobre esta solución sencilla e innovadora.\u003c\/p\u003e\n\u003c!-- Output Impedance --\u003e\n\n\u003csection\u003e\n\u003ch3\u003eImpedancia de salida (medición de estabilidad no invasiva)\u003c\/h3\u003e\n\n\u003cdiv class=\"output-impedance\"\u003e\n\u003cp\u003eLa gráfica de impedancia de salida contiene información sobre la estabilidad del lazo de realimentación y sobre la red de desacoplo. Utilice el método NISM (Non-Invasive Stability Measurement) para obtener el margen de fase a partir de una única medición de impedancia de salida. Consulte esta nota de aplicación para saber cómo realizar esta medición sencilla y rápida. Consulte también los accesorios de Picotest para simplificar las mediciones de integridad de alimentación.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e\u003cimg alt=\"Impedancia de salida (medición de estabilidad no invasiva)\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"115\" src=\"https:\/\/www.omicron-lab.com\/fileadmin\/_processed_\/4\/2\/csm_OutputImpedance_813d6ff2fd.png\" width=\"255\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Input Impedance \u0026 Filter Stability --\u003e\n\n\u003csection\u003e\n\u003ch3\u003eImpedancia de entrada y estabilidad del filtro\u003c\/h3\u003e\n\n\u003cdiv class=\"input-impedance\"\u003e\n\u003cp\u003eLa resistencia de entrada negativa de un convertidor CC\/CC puede provocar oscilaciones si se utiliza un filtro de entrada sin amortiguar. El Bode 100 permite comprobar la impedancia de entrada del convertidor y el espectro de impedancia del filtro que podría causar problemas de inestabilidad en la resonancia. Consulte la nota de aplicación sobre estabilidad del filtro de entrada para obtener más información.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e\u003cimg alt=\"Impedancia de entrada y estabilidad del filtro\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"134\" src=\"https:\/\/www.omicron-lab.com\/fileadmin\/_processed_\/d\/d\/csm_InputImpedanceSchematic_c48f8cc45d.png\" width=\"400\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Component Impedance Plot --\u003e\n\n\u003csection\u003e\n\u003ch3\u003eGráfica de impedancia de componentes\u003c\/h3\u003e\n\n\u003cdiv class=\"component-impedance\"\u003e\n\u003cp\u003eLa gráfica de impedancia de los componentes electrónicos ofrece una visión detallada de sus propiedades en CA, como la ESR de los condensadores, la inductancia de fuga de los transformadores, la resistencia en CA de los devanados, la frecuencia de autorresonancia de inductores y transformadores, la inductancia de las resistencias shunt, la capacidad entre devanados de los transformadores, etc. Utilice el Bode 100 para realizar mediciones de impedancia rápidas y precisas de 1 Hz a 50 MHz. Vea nuestro seminario web para conocer las posibilidades del Bode 100 como analizador de impedancia.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"video\"\u003e\u003c!-- Video content is missing, please provide the correct video source --\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Power Supply Rejection Ratio --\u003e\n\n\u003csection\u003e\n\u003ch3\u003eRelación de rechazo de la fuente de alimentación (PSRR)\u003c\/h3\u003e\n\n\u003cdiv class=\"psrr\"\u003e\n\u003cp\u003eLa relación de rechazo de la fuente de alimentación, también conocida como rechazo del rizado de alimentación, indica en qué medida se rechazan en la salida las perturbaciones de la línea. Esta información resulta especialmente útil en fuentes de bajo ruido y reguladores lineales. Consulte esta nota de aplicación para saber cómo realizar una medición de PSRR.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e \u003c\/div\u003e\n\u003c\/section\u003e","brand":"OMICRON-Lab","offers":[{"title":"Estándar","offer_id":54978417951095,"sku":"P0005755","price":5920.0,"currency_code":"GBP","in_stock":true},{"title":"Básico","offer_id":54978417983863,"sku":"P0005756","price":5450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-vector-network-analyser-omicron-lab-bode-100-vector-network-analyser-36889562939615.jpg?v=1684966435"},{"product_id":"omicron-lab-b-smc-impedance-adapter-uk","title":"OMICRON Lab B-SMC - Impedance Test Fixture for SM Components","description":"\u003cp\u003eThe OMICRON Lab B-SMC is an impedance test fixture for surface-mount components that turns a Bode 100 into an LCR meter or impedance analyser, usable from 1 Hz to 50 MHz over a recommended impedance range of 20 mΩ to 600 kΩ. A gold-plated needle electrode, set by a knurled nut, clamps SMD parts up to 9.5 mm long and 7.5 mm wide against a gold-plated pad, with a contact resistance of around 0.5 mΩ. Hardware and power electronics engineers use it for RLC-Q measurement of chip resistors, capacitors and inductors across frequency.\u003c\/p\u003e\n\n\u003ch2\u003eSMD Impedance Measurement From 1 Hz to 50 MHz\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab specifies a usable frequency range of 1 Hz to 50 MHz and recommends the fixture for impedances from 20 mΩ to 600 kΩ. Inside is a resistive measurement bridge with a voltage divider and a current shunt: CH1 receives a signal proportional to the DUT voltage and CH2 a signal proportional to the DUT current. The Bode Analyzer Suite runs it in the Impedance Adapter measurement mode.\u003c\/p\u003e\n\n\u003ch2\u003eNeedle Electrode for Surface-Mount Parts up to 9.5 x 7.5 mm\u003c\/h2\u003e\n\u003cp\u003eThe DUT sits on the electrode pad under the centre needle electrode, and the knurled nut sets the needle-to-pad distance to match the part. The largest DUT the B-SMC takes is 9.5 mm long and 7.5 mm wide. Gold plating brings contact resistance down to around 0.5 mΩ, so clean the needle and pad before Short calibration and low-value measurements.\u003c\/p\u003e\n\n\u003ch2\u003eImpedance Test Fixture Setup and Calibration with the Bode 100\u003c\/h2\u003e\n\u003cp\u003eThree BNC sockets connect the fixture to the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e: SOURCE from the analyser output, CH1 and CH2 to the matching inputs. Open, Short and Load calibration is required before measuring. For Open, set the needle-to-pad gap to the DUT size so stray capacitance is compensated. For Short, loosen the knurled nut until the needle touches the electrode. For Load, place a 100 Ω resistor between needle and electrode; six 0603 load resistors (100 Ω ±0.1%, 15 ppm\/°C) are supplied for this. OMICRON Lab characterised typical relative accuracy against an Agilent E4980A precision LCR meter at 10 Hz receiver bandwidth, and publishes the chart in the B-WIC and B-SMC user manual.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended impedance range\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement principle\u003c\/th\u003e\n\u003ctd\u003eResistive bridge (voltage divider and current shunt), CH1 voltage, CH2 current\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eBNC sockets: SOURCE, CH1, CH2 (outer conductor connected to housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT contacts\u003c\/th\u003e\n\u003ctd\u003eGold-plated needle electrode and pad with spring mechanics\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContact resistance\u003c\/th\u003e\n\u003ctd\u003eApprox. 0.5 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. DUT size\u003c\/th\u003e\n\u003ctd\u003e9.5 mm length, 7.5 mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLoad calibration resistors\u003c\/th\u003e\n\u003ctd\u003e0603, 100 Ω ±0.1%, 15 ppm\/°C (6 pcs. supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e100.5 x 68.2 x 55.5 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-35 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20% to 80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSELV device (IEC 60950), protection class III\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser is not included. OMICRON Lab states the B-SMC is to be used only in conjunction with the Bode 100. Its B-SMC documentation does not cover the Bode 500, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eDo not apply external voltages or currents. No DC bias rating is published.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab publishes a typical relative accuracy chart, not a guaranteed accuracy figure, and states the accuracy rating can change without notice.\u003c\/li\u003e\n  \u003cli\u003eFor leaded parts, choose the \u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e, which takes wires up to 1.8 mm in diameter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eImpedance Test Fixture Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-SMC\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eComponent type\u003c\/th\u003e\n\u003ctd\u003eSurface-mount\u003c\/td\u003e\n\u003ctd\u003eWired (through-hole)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT limits\u003c\/th\u003e\n\u003ctd\u003eUp to 9.5 mm long, 7.5 mm wide\u003c\/td\u003e\n\u003ctd\u003eWire diameter up to 1.8 mm, spacing min. 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended impedance range\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibration items supplied\u003c\/th\u003e\n\u003ctd\u003e6 x 0603 load resistors, 100 Ω ±0.1%\u003c\/td\u003e\n\u003ctd\u003eB-CAL calibration board (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eCapacitance and ESR of MLCCs and other chip capacitors, using the 20 mΩ low end of the recommended range. Inductance and Q of SMD power inductors swept up to 50 MHz. Impedance against frequency of chip resistors and ferrite beads, to see where parasitic inductance or capacitance takes over.\u003c\/p\u003e\n\u003cp\u003eThe B-SMC suits engineers who already own a Bode 100 and need repeatable impedance measurements on surface-mount passives without building a test board.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-SMC impedance test fixture\u003c\/li\u003e\n  \u003cli\u003eLoad calibration resistors, 100 Ω ±0.1%, size 0603 (6 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-SMC is \u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e ex VAT. If you also need the analyser, contact us for a formal quotation covering the Bode 100 and fixture. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the B-SMC Work with the Bode 500?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab's B-SMC documentation names only the Bode 100, and the user manual says to use the fixture only in conjunction with the Bode 100. The Bode 500 also has N-type connectors where the B-SMC uses BNC. Contact us before ordering if your analyser is a Bode 500.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eDoes the B-SMC Use the B-CAL-3 Calibration Board?\u003c\/h3\u003e\n\u003cp\u003eNo. The B-CAL-3 is the calibration element for the B-WIC. The B-SMC calibrates Short by closing the needle onto the electrode and Load with a 100 Ω resistor between needle and electrode. Six 0603 resistors (100 Ω ±0.1%) ship with the fixture, and OMICRON Lab recommends a precision thin-film 100 Ω resistor with low temperature coefficient for best accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat Is the Largest SMD Part the B-SMC Can Hold?\u003c\/h3\u003e\n\u003cp\u003e9.5 mm long and 7.5 mm wide. The needle electrode sits in the centre, so position the part under it and set the gap with the knurled nut.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/impedance-test-fixtures-b-wic-b-smc\"\u003eOMICRON Lab Impedance Test Fixtures B-WIC and B-SMC\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-smc-impedance-test-fixture-for-surface-mounted-components\"\u003eOMICRON Lab Shop: B-SMC Impedance Test Fixture\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541401276639,"sku":"P0005759","price":650.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-impedance-adapter-omicron-lab-b-smc-impedance-adapter-for-sm-components-36889492848863.jpg?v=1684970931"},{"product_id":"omicron-lab-b-wic-impedance-adapter-uk","title":"OMICRON Lab B-WIC - Impedance Test Fixture for Wired Components","description":"\u003cp\u003eThe OMICRON Lab B-WIC is an impedance test fixture for wired (through-hole) components that turns a Bode 100 into an LCR meter or impedance analyser, usable from 1 Hz to 50 MHz over a recommended impedance range of 20 mΩ to 600 kΩ. Gold-plated, spring-loaded electrodes take leads up to 1.8 mm in diameter with a contact resistance of around 0.5 mΩ. Hardware and power electronics engineers use it for RLC-Q measurement of leaded resistors, capacitors and inductors across frequency.\u003c\/p\u003e\n\n\u003ch2\u003eRLC-Q Measurement From 1 Hz to 50 MHz\u003c\/h2\u003e\n\u003cp\u003eThe B-WIC is optimised for RLC-Q measurement of common passive components. OMICRON Lab specifies a usable frequency range of 1 Hz to 50 MHz and recommends the fixture for impedances from 20 mΩ to 600 kΩ. Inside is a resistive measurement bridge with a voltage divider and a current shunt: CH1 receives a signal proportional to the DUT voltage and CH2 a signal proportional to the DUT current. The Bode Analyzer Suite runs it in the Impedance Adapter measurement mode.\u003c\/p\u003e\n\n\u003ch2\u003eGold-Plated Electrodes for Wired Components\u003c\/h2\u003e\n\u003cp\u003eThe electrodes are 24 mm long and accept DUT wires up to 1.8 mm in diameter, with a minimum clearance of 3 mm between wires. Contact resistance is around 0.5 mΩ, which matters at the low end of the impedance range, so clean the gold-plated contacts before Short calibration and low-value measurements. Keep leads short. Extra lead length and large DUTs add stray capacitance and measurement error.\u003c\/p\u003e\n\n\u003ch2\u003eImpedance Test Fixture Setup and Calibration with the Bode 100\u003c\/h2\u003e\n\u003cp\u003eThree BNC sockets connect the fixture to the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e: SOURCE from the analyser output, CH1 and CH2 to the matching inputs. Open, Short and Load calibration is required before measuring. Open is run with no DUT fitted; Short and Load use the supplied B-CAL calibration board, inserted short side then load side. Accuracy depends on these calibration elements and on clean contacts. OMICRON Lab characterised typical relative accuracy against an Agilent E4980A precision LCR meter at 10 Hz receiver bandwidth, and publishes the chart in the B-WIC and B-SMC user manual.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended impedance range\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement principle\u003c\/th\u003e\n\u003ctd\u003eResistive bridge (voltage divider and current shunt), CH1 voltage, CH2 current\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eBNC sockets: SOURCE, CH1, CH2 (outer conductor connected to housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT contacts\u003c\/th\u003e\n\u003ctd\u003eGold-plated electrodes with spring mechanics\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContact resistance\u003c\/th\u003e\n\u003ctd\u003eApprox. 0.5 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. DUT wire diameter\u003c\/th\u003e\n\u003ctd\u003e1.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMin. DUT wire spacing\u003c\/th\u003e\n\u003ctd\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eElectrode length\u003c\/th\u003e\n\u003ctd\u003e24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e100.5 x 68.2 x 55.5 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-35 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20% to 80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSELV device (IEC 60950), protection class III\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser is not included. OMICRON Lab states the B-WIC is to be used only in conjunction with the Bode 100. Its B-WIC documentation does not cover the Bode 500, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eDo not apply external voltages or currents. No DC bias rating is published.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab publishes a typical relative accuracy chart, not a guaranteed accuracy figure, and states the accuracy rating can change without notice.\u003c\/li\u003e\n  \u003cli\u003eFor surface-mount parts, choose the \u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e, which takes DUTs up to 9.5 mm long and 7.5 mm wide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eImpedance Test Fixture Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-WIC\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eComponent type\u003c\/th\u003e\n\u003ctd\u003eWired (through-hole)\u003c\/td\u003e\n\u003ctd\u003eSurface-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT limits\u003c\/th\u003e\n\u003ctd\u003eWire diameter up to 1.8 mm, spacing min. 3 mm\u003c\/td\u003e\n\u003ctd\u003eUp to 9.5 mm long, 7.5 mm wide\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended impedance range\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003ctd\u003e20 mΩ to 600 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eInductance and Q of leaded inductors and chokes swept up to 50 MHz. Capacitance and ESR of through-hole capacitors, using the 20 mΩ low end of the recommended range. Impedance against frequency of leaded resistors, to see where parasitic inductance or capacitance takes over.\u003c\/p\u003e\n\u003cp\u003eThe B-WIC suits engineers who already own a Bode 100 and need repeatable impedance measurements on leaded passives without building their own fixture.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-WIC impedance test fixture\u003c\/li\u003e\n  \u003cli\u003eB-CAL calibration board (1 pc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-WIC is \u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e ex VAT. If you also need the analyser, contact us for a formal quotation covering the Bode 100 and fixture. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/impedance-test-fixtures-b-wic-b-smc\"\u003eOMICRON Lab Impedance Test Fixtures B-WIC and B-SMC\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-wic-impedance-test-fixture-for-through-hole-type-components\"\u003eOMICRON Lab Shop: B-WIC Impedance Test Fixture\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541402816735,"sku":"P0005760","price":650.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-impedance-adapter-omicron-lab-b-wic-impedance-adapter-for-wired-components-36889493012703.jpg?v=1684966247"},{"product_id":"omicron-lab-b-wit-100-wideband-injection-transformer-uk","title":"OMICRON Lab B-WIT 100 Wideband Injection Transformer","description":"\u003cp\u003eThe OMICRON Lab B-WIT 100 is a wideband injection transformer for loop gain and stability measurement, usable from 1 Hz to 10 MHz with a 1:1 turns ratio, under 0.5 dB insertion loss at 10 kHz and isolation rated to 600 V CAT II. It couples the source output of a Bode 100 or another frequency response analyser across an injection resistor in the control loop. Power supply designers use it to measure gain and phase margin on DC\/DC converters and voltage regulators, in the lab or on a manufacturing test station.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement From 1 Hz to 10 MHz\u003c\/h2\u003e\n\u003cp\u003eThe usable frequency range runs from 1 Hz to 10 MHz, with a typical -3 dB range of 7 Hz to 5 MHz. Insertion loss is under 0.5 dB at 10 kHz (S21, 50 Ω termination), and the typical primary-to-secondary capacitance of 120 pF at 1 kHz keeps loading of the loop under test low. Typical volt-second capacity is 3.5 mVs and the maximum input voltage is 10 Vrms.\u003c\/p\u003e\n\n\u003ch2\u003eInjection Transformer Setup with the Bode 100\u003c\/h2\u003e\n\u003cp\u003eThe BNC input plug connects to the source output of the analyser, such as the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. The isolated output on 4 mm safety banana jacks goes across an injection resistor placed in the feedback path. OMICRON Lab specifies a resistor of 1 Ω to 10 Ω and recommends 10 Ω. Two voltage probes pick up the signal on either side of the resistor and the analyser plots loop gain from their ratio. Because the disturbance is injected differentially, the DC operating point of the converter is not disturbed.\u003c\/p\u003e\n\n\u003ch2\u003e600 V CAT II Isolation for Off-Line Supplies\u003c\/h2\u003e\n\u003cp\u003eIsolation between input and output is rated to 600 V CAT II, so the injection point can sit at a high potential while the analyser stays referenced to earth. An earth terminal on the housing must be connected to safety ground whenever voltages above 30 VAC or 60 VDC are present. Maximum current is 1 A, limited by an internal fuse that is not user-replaceable.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e-3 dB frequency range\u003c\/th\u003e\n\u003ctd\u003e7 Hz to 5 MHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB at 10 kHz (S21, 50 Ω termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrimary-secondary capacitance\u003c\/th\u003e\n\u003ctd\u003e120 pF at 1 kHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. volt-second\u003c\/th\u003e\n\u003ctd\u003e3.5 mVs (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDC saturation current\u003c\/th\u003e\n\u003ctd\u003e15 mA (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e10 Vrms (absolute maximum, user manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. current\u003c\/th\u003e\n\u003ctd\u003e1 A (fuse, not user-replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eBNC plug\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput connectors\u003c\/th\u003e\n\u003ctd\u003e4 mm safety banana jacks (isolated), plus earth terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended injection resistor\u003c\/th\u003e\n\u003ctd\u003e1 Ω to 10 Ω (10 Ω recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e129 x 64 x 32.5 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and voltage probes are not included. The B-WIT 100 is the injection element only.\u003c\/li\u003e\n  \u003cli\u003eDC saturation current is 15 mA (typ.). OMICRON Lab states that no DC signal may be applied to the output.\u003c\/li\u003e\n  \u003cli\u003eBelow 1 Hz, choose the \u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e: its lower -3 dB point is under 100 mHz (typ.) and it injects a 1 Hz signal at the Bode 100's full 2 Vrms output without saturating, for slow loops such as PFC regulators.\u003c\/li\u003e\n  \u003cli\u003eAbove 10 MHz, consider the \u003ca href=\"\/es\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e, specified for 10 Hz to 45 MHz into a 5 Ω termination.\u003c\/li\u003e\n  \u003cli\u003eDo not open or modify the unit. It has no user-serviceable parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInjection Transformer Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-WIT 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 10 MHz (usable)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mHz to \u0026gt; 15 kHz (-3 dB, typ. 20 kHz upper)\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 45 MHz (5 Ω termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB at 10 kHz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 dB at 100 Hz\u003c\/td\u003e\n\u003ctd\u003eNot stated by Picotest\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003e£550\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eGain and phase margin measurement on DC\/DC converter control loops with a Bode 100, using a 10 Ω injection resistor in the feedback divider path. Loop stability checks on linear voltage regulators across the 7 Hz to 5 MHz -3 dB band. Production verification of loop stability on a manufacturing test station, with the injection path isolated to 600 V CAT II and safety-rated probes.\u003c\/p\u003e\n\u003cp\u003eThe B-WIT 100 suits power electronics engineers who already own a frequency response analyser and need one injection transformer that spans both mid-frequency and fast switching-converter loops.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-WIT 100 injection transformer\u003c\/li\u003e\n  \u003cli\u003eBNC to 4 mm banana adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-WIT 100 is \u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e ex VAT. If your loop crosses over below 1 Hz, check the B-LFT 100 first, or contact us for a formal quotation covering the analyser and probes. See all \u003ca href=\"\/es\/collections\/injection-transformers-catalogue\"\u003einjection transformers\u003c\/a\u003e we stock.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/picotest-products\/product-overview\/signal-injectors\"\u003eOMICRON Lab Picotest Signal Injectors\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541404225759,"sku":"P0005758","price":545.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-injection-transformer-omicron-lab-b-wit-100-wideband-injection-transformer-36889495109855.jpg?v=1684963184"},{"product_id":"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk","title":"OMICRON Lab B-LFT 100 Low-Frequency Injection Transformer","description":"\u003cp\u003eThe OMICRON Lab B-LFT 100 is a low-frequency injection transformer for loop gain measurement on slow control loops, with a usable range of 10 mHz to 100 kHz, a 1:1 turns ratio, insertion loss under 1 dB at 100 Hz and isolation rated to 600 V CAT II. It injects a 1 Hz signal at the full 2 Vrms output of a Bode 100 without saturating. Power electronics engineers use it to measure gain and phase margin on PFC regulators and other slow loops.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement Down to 10 mHz\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab specifies a usable frequency range of 10 mHz to 100 kHz. The typical lower -3 dB point is below 100 mHz and the upper -3 dB point is above 15 kHz (20 kHz typical), with attenuation of approximately 20 dB at 100 kHz. Insertion loss is under 1 dB at 100 Hz, measured as input-to-output voltage gain with a 1 kΩ secondary resistance and a 0 dBm source. Typical volt-second capacity is 0.456 Vs, against 3.5 mVs for the wideband B-WIT 100.\u003c\/p\u003e\n\n\u003ch2\u003eInjection Transformer Setup with a 1 kΩ Injection Resistor\u003c\/h2\u003e\n\u003cp\u003eThe BNC input plug connects to the source output of the analyser, such as the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. The isolated output on 4 mm safety banana jacks goes across the injection resistor in the feedback path. The B-LFT 100 is designed for a 1 kΩ injection resistor. The \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e uses 1 Ω to 10 Ω, so check the resistor before swapping. Two voltage probes either side of the resistor give the analyser the loop gain ratio. Because the disturbance is injected differentially, the DC operating point of the loop is not disturbed.\u003c\/p\u003e\n\n\u003ch2\u003e600 V CAT II Isolation for Off-Line Supplies\u003c\/h2\u003e\n\u003cp\u003ePrimary-to-secondary isolation is rated to 600 V CAT II, so the injection point can sit at a high potential while the analyser stays referenced to earth. Connect the earth terminal on the housing to safety ground whenever voltages above 30 VAC or 60 VDC are present. Typical primary-to-secondary capacitance is 600 pF at 1 kHz. Output current is limited to 0.1 A by a fuse in the output winding, which is not user-replaceable.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003e10 mHz to 100 kHz (approx. 20 dB attenuation at 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLower -3 dB frequency\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 100 mHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUpper -3 dB frequency\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 15 kHz (20 kHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 dB at 100 Hz (1 kΩ secondary resistance, 0 dBm source)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrimary-secondary capacitance\u003c\/th\u003e\n\u003ctd\u003e600 pF at 1 kHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. volt-second\u003c\/th\u003e\n\u003ctd\u003e0.456 Vs (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDC saturation current\u003c\/th\u003e\n\u003ctd\u003e0.8 mA (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e10 Vrms (absolute maximum, user manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAbsolute max. current\u003c\/th\u003e\n\u003ctd\u003e0.1 A (fuse in output winding, not user-replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput connector\u003c\/th\u003e\n\u003ctd\u003eBNC plug\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput connectors\u003c\/th\u003e\n\u003ctd\u003e4 mm safety banana jacks (isolated), plus earth terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInjection resistor\u003c\/th\u003e\n\u003ctd\u003e1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e183 x 122 x 61 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and voltage probes are not included. The B-LFT 100 is the injection element only.\u003c\/li\u003e\n  \u003cli\u003eDC saturation current is 0.8 mA (typ.). OMICRON Lab states that no DC signal may be applied to the output.\u003c\/li\u003e\n  \u003cli\u003eResponse rolls off above the 15 kHz (min.) upper -3 dB point. For loops that cross over in the kHz to MHz range, choose the B-WIT 100 (1 Hz to 10 MHz usable) or the \u003ca href=\"\/es\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e, specified for 10 Hz to 45 MHz into a 5 Ω termination.\u003c\/li\u003e\n  \u003cli\u003eDo not open or modify the unit. It has no user-serviceable parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInjection Transformer Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-LFT 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003ePicotest J2101A\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e10 mHz to 100 kHz usable; \u0026lt; 100 mHz to \u0026gt; 15 kHz (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 10 MHz usable; 7 Hz to 5 MHz (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 45 MHz (5 Ω termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTurns ratio\u003c\/th\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 dB at 100 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 dB at 10 kHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by Picotest\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInjection resistor\u003c\/th\u003e\n\u003ctd\u003e1 kΩ\u003c\/td\u003e\n\u003ctd\u003e1 Ω to 10 Ω\u003c\/td\u003e\n\u003ctd\u003e5 Ω termination\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003eTested to 600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"picotest-j2101a-injection-transformer-10hz-45mhz-uk\"\u003e£550\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eGain and phase margin measurement on the control loop of a PFC regulator with a Bode 100, sweeping from below 1 Hz with a 1 kΩ injection resistor. Stability checks on other slow regulation loops whose crossover sits below the 1 Hz floor of the B-WIT 100.\u003c\/p\u003e\n\u003cp\u003eThe B-LFT 100 suits power electronics engineers who already own a frequency response analyser and need to reach the sub-hertz region that a wideband injection transformer cannot cover.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-LFT 100 injection transformer\u003c\/li\u003e\n  \u003cli\u003eBNC to 4 mm banana adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-LFT 100 is \u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e ex VAT. If your loop crosses over above 15 kHz, check the B-WIT 100 first, or contact us for a formal quotation covering the analyser and probes. See all \u003ca href=\"\/es\/collections\/injection-transformers-catalogue\"\u003einjection transformers\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 30 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/picotest-products\/product-overview\/signal-injectors\"\u003eOMICRON Lab Picotest Signal Injectors\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.picotest.com\/product\/j2101a-injection-transformer-10hz-45mhz\/\"\u003ePicotest J2101A Injection Transformer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541406060767,"sku":"P0005773","price":760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-injection-transformer-omicron-lab-b-lft-100-low-frequency-injection-transformer-36889477480671.jpg?v=1684962844"},{"product_id":"omicron-lab-b-lcm-low-frequency-common-mode-choke-uk","title":"OMICRON Lab B-LCM Low Frequency Common Mode Choke","description":"\u003cp\u003eThe OMICRON Lab B-LCM is a low frequency common mode choke that reduces ground-loop current errors in impedance measurements, usable from DC to above 50 MHz with a recommended range of 100 Hz to 10 MHz. It offers at least 75 mH of common mode inductance at 1 kHz, typical common-mode rejection above 40 dB at 1 Hz and above 60 dB at 1 kHz, and differential insertion loss of 0.08 dB or less up to 100 kHz. Power electronics engineers use it with a Bode 100 for Shunt-Thru measurements of very low impedances.\u003c\/p\u003e\n\n\u003ch2\u003eGround-Loop Error in Shunt-Thru Measurements\u003c\/h2\u003e\n\u003cp\u003eIn a Shunt-Thru setup, current flowing through the cable shield of the connection to Channel 2 ground introduces a measurement error. OMICRON Lab notes that this error can become significant when measuring very low impedance values at frequencies below 10 kHz to 100 kHz. The B-LCM attenuates that low frequency ground loop current, so the measured impedance reflects the DUT rather than the test cabling. The user manual shows the typical setup with the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Mode Choke Performance From DC to 50 MHz\u003c\/h2\u003e\n\u003cp\u003eCommon mode inductance is at least 75 mH at 1 kHz. Typical common-mode rejection is above 40 dB at 1 Hz and above 60 dB at 1 kHz. For the wanted signal the choke stays nearly transparent: differential mode insertion loss is 0.08 dB or less up to 100 kHz, 0.7 dB or less to 40 MHz and 0.75 dB or less to 50 MHz. Return loss is -37 dB or better up to 100 kHz and -22 dB or better up to 50 MHz. Input-output capacitance is 175 pF to 205 pF at 1 MHz (190 pF typical).\u003c\/p\u003e\n\n\u003ch2\u003eCommon-Mode Suppression and Channel Quasi-Isolation\u003c\/h2\u003e\n\u003cp\u003eBeyond Shunt-Thru work, OMICRON Lab lists two further uses: reducing or suppressing common-mode signals in a test setup, and quasi-isolating an input channel at high frequencies. The B-LCM sits in a metal housing with BNC input and output plugs, both marked ≤ 30 V.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to \u0026gt; 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003e100 Hz to 10 MHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCommon mode inductance\u003c\/th\u003e\n\u003ctd\u003e≥ 75 mH at 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCommon-mode rejection\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 40 dB at 1 Hz (typ.); \u0026gt; 60 dB at 1 kHz (typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput-output capacitance\u003c\/th\u003e\n\u003ctd\u003e175 pF to 205 pF at 1 MHz (typ. 190 pF)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDifferential mode insertion loss\u003c\/th\u003e\n\u003ctd\u003e≤ 0.08 dB up to 100 kHz; ≤ 0.7 dB above 100 kHz to 40 MHz; ≤ 0.75 dB above 40 MHz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eReturn loss\u003c\/th\u003e\n\u003ctd\u003e≤ -37 dB up to 100 kHz; ≤ -32 dB to 2 MHz; ≤ -27 dB to 5 MHz; ≤ -22 dB to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eBNC input plug and BNC output plug (≤ 30 V), metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e141 x 65 x 32 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-35 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20% to 80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSELV device (IEC 60950), protection class III\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and DUT connections are not included. The B-LCM is the choke only.\u003c\/li\u003e\n  \u003cli\u003eBelow the 100 Hz recommended lower limit, rejection falls: OMICRON Lab gives \u0026gt; 40 dB at 1 Hz (typ.) against \u0026gt; 60 dB at 1 kHz.\u003c\/li\u003e\n  \u003cli\u003eThe B-LCM is not an injection transformer and carries no isolation rating. For loop gain injection, choose the \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab's B-LCM documentation names the Bode 100. Ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSignal Injector and Choke Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-LCM\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eCommon mode choke, ground-loop suppression\u003c\/td\u003e\n\u003ctd\u003eWideband injection transformer\u003c\/td\u003e\n\u003ctd\u003eLow-frequency injection transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003eDC to \u0026gt; 50 MHz usable; 100 Hz to 10 MHz recommended\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 10 MHz usable\u003c\/td\u003e\n\u003ctd\u003e10 mHz to 100 kHz usable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003ctd\u003eShunt-Thru low-impedance measurement\u003c\/td\u003e\n\u003ctd\u003eLoop gain, DC\/DC converters\u003c\/td\u003e\n\u003ctd\u003eLoop gain, PFC and slow loops\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003eNone rated\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003ctd\u003e600 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003ctd\u003e1.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lcm-low-frequency-common-mode-choke-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003e£545\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003e£760\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eShunt-Thru impedance measurement of milliohm-level power rail decoupling with a Bode 100, where ground-loop error can become significant below 10 kHz to 100 kHz. ESR and impedance measurement of low-value capacitors at low frequency. Suppressing common-mode signals that couple into a measurement channel through the cable shields.\u003c\/p\u003e\n\u003cp\u003eThe B-LCM suits engineers who already run Shunt-Thru measurements and see the low-frequency impedance floor rise from the test setup rather than the DUT.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-LCM low frequency common mode choke\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-LCM is \u003cspan data-ds-price=\"omicron-lab-b-lcm-low-frequency-common-mode-choke-uk\"\u003e£545\u003c\/span\u003e ex VAT. Contact us for a formal quotation covering the Bode 100 and accessories, or see all \u003ca href=\"\/es\/collections\/signal-injectors-catalogue\"\u003esignal injectors\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhen Do I Need the B-LCM?\u003c\/h3\u003e\n\u003cp\u003eWhen measuring very low impedances in a Shunt-Thru setup at frequencies below 10 kHz to 100 kHz. In that region the current in the Channel 2 cable shield introduces an error that the B-LCM attenuates.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eDoes the B-LCM Affect the Measured Signal?\u003c\/h3\u003e\n\u003cp\u003eVery little. Differential mode insertion loss is 0.08 dB or less up to 100 kHz and 0.75 dB or less up to 50 MHz, with return loss of -37 dB or better below 100 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the B-LCM an Isolation Transformer?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a common mode choke and OMICRON Lab publishes no isolation rating for it. Both BNC connectors are marked ≤ 30 V. For isolated loop gain injection, use the B-WIT 100 or B-LFT 100, both rated 600 V CAT II.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-lcm\"\u003eOMICRON Lab B-LCM Low Frequency Common Mode Choke\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-lcm\"\u003eOMICRON Lab Shop: B-LCM\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541579206879,"sku":"P0005778","price":545.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-components-omicron-lab-b-lcm-low-frequency-common-mode-choke-36889477087455.jpg?v=1684966604"},{"product_id":"omicron-lab-b-amp-12-external-power-amplifier-uk","title":"OMICRON Lab B-AMP 12 External Power Amplifier - 12dB Gain 50MHz","description":"\u003csection class=\"product-rich\"\u003e \u003ch2\u003eProfessional External Power Amplifier for Vector Network Analysis\u003c\/h2\u003e \u003cp\u003eThe OMICRON Lab B-AMP 12 is a precision external power amplifier designed specifically for use with the Bode 100 vector network analyser. This professional-grade amplifier delivers a consistent 12 dB gain (×4 amplification) across the entire DC to 50 MHz frequency range, enabling high-power measurements up to 25 dBm output level.\u003c\/p\u003e \u003ch3\u003eHigh-Performance 50Ω System Design\u003c\/h3\u003e \u003cp\u003eBuilt around a true 50Ω input and output impedance design, the B-AMP 12 provides excellent return loss performance (\u0026gt;30 dB) ensuring minimal signal reflections and accurate measurements. The amplifier features dedicated impedance measurement ports (CH1 and CH2) that provide defined attenuation levels for direct impedance measurements at high signal levels.\u003c\/p\u003e \u003cdiv class=\"spec-note\"\u003e \u003cstrong\u003eKey Specifications:\u003c\/strong\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eDC – 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eGain\u003c\/td\u003e\n\u003ctd\u003e12 dB ±0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMaximum Output\u003c\/td\u003e\n\u003ctd\u003e25 dBm (11.3 VPP) into 50Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInput\/Output Impedance\u003c\/td\u003e\n\u003ctd\u003e50Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10-36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eWiring Quick-Start\u003c\/h3\u003e \u003cp\u003eConnect the B-AMP 12 between your Bode 100 output and device under test:\u003c\/p\u003e \u003cpre\u003e\u003ccode\u003e Bode 100 OUTPUT → B-AMP 12 INPUT (BNC) B-AMP 12 OUTPUT → Device Under Test B-AMP 12 CH1 ← Bode 100 CH1 (for impedance measurements) B-AMP 12 CH2 ← Bode 100 CH2 (for impedance measurements) Power: 10-36 VDC via 2.5mm\/5.5mm coaxial socket \u003c\/code\u003e\u003c\/pre\u003e \u003cdiv class=\"aside\"\u003e \u003cstrong\u003eImportant:\u003c\/strong\u003e Always ensure proper 50Ω termination on all ports before applying power. The B-AMP 12 has no output activity indicator - use caution when external amplifiers are connected. \u003c\/div\u003e \u003ch3\u003eAdvanced Measurement Capabilities\u003c\/h3\u003e \u003cp\u003eThe integrated CH1 and CH2 measurement ports provide calibrated signal paths for impedance analysis:\u003c\/p\u003e \u003cdiv class=\"tbl\"\u003e \u003ctable\u003e \u003ctr\u003e\n\u003ctd\u003eInput to CH1 attenuation\u003c\/td\u003e\n\u003ctd\u003e14.5 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInput to CH2 attenuation\u003c\/td\u003e\n\u003ctd\u003e20.8 dB typ.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOutput to CH2 voltage gain\u003c\/td\u003e\n\u003ctd\u003e-33 dB (×0.022)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCH1\/CH2 return loss\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;25 dB\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp\u003eThese measurement ports enable direct impedance measurements with high AC signal levels, essential for characterising voltage-dependent components like chip capacitors and varactors.\u003c\/p\u003e \u003cdiv class=\"imgph\"\u003eHero image: B-AMP 12 front panel showing BNC connectors and power LED\u003c\/div\u003e \u003cp\u003eRelated products: \u003ca href=\"https:\/\/thedebugstore.com\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eOMICRON Lab Bode 100 VNA\u003c\/a\u003e and \u003ca href=\"https:\/\/thedebugstore.com\/products\/omicron-lab-b-lcm-low-frequency-common-mode-choke-uk\"\u003eB-LCM Common Mode Choke\u003c\/a\u003e.\u003c\/p\u003e \u003c\/section\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541604700383,"sku":"P0005772","price":950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-amplfier-omicron-lab-b-amp-12-external-power-amplifier-36889468928223.jpg?v=1684970940"},{"product_id":"omicron-lab-carrying-case-for-bode-100-uk","title":"OMICRON Lab Carrying Case for Bode 100 and Bode 500","description":"\u003cp\u003eThe OMICRON Lab Carrying Case (E1399000) is a protective carry case for the Bode 100 or Bode 500 vector network analyser, with a custom cut-out foam interior that holds the analyser, its cables, the power supply and up to four accessories. It measures 44.5 x 36.5 x 13.7 cm and weighs 1.5 kg empty. Engineers who move one Bode analyser between the development lab, a production test area and customer sites use it to keep the whole measurement kit together.\u003c\/p\u003e\n\n\u003ch2\u003eCut-Out Foam for the Bode 100 or Bode 500\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab sells one carry case for both analysers, the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e and the \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e. The foam is cut out to locate the analyser and the parts that travel with it, so nothing loose rattles around in transit. OMICRON Lab does not publish a shell material, an ingress rating or a drop rating, so treat it as a transport and storage case rather than a rated flight case.\u003c\/p\u003e\n\n\u003ch2\u003eRoom for Cables, Power Supply and Four Accessories\u003c\/h2\u003e\n\u003cp\u003eAlongside the analyser there are spaces for its measurement cables, its power supply and up to four accessories. OMICRON Lab's own example layout carries a Bode 100 with a \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e injection transformer, a \u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e test fixture for surface-mount components and a \u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e test fixture for wired components. That puts a loop gain setup and an impedance measurement setup in one case, with one slot to spare.\u003c\/p\u003e\n\n\u003ch2\u003eBode Analyser Carry Case Dimensions and Weight\u003c\/h2\u003e\n\u003cp\u003eExternal dimensions are 44.5 x 36.5 x 13.7 cm (W x H x D), which is 17.5 x 14.4 x 5.4 in. The empty case weighs 1.5 kg (3.3 lb), so most of what you carry is the instrument and its accessories.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eE1399000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInterior\u003c\/th\u003e\n\u003ctd\u003eCustom cut-out foam\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003eBode analyser, cables, power supply and up to 4 accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e44.5 x 36.5 x 13.7 cm (17.5 x 14.4 x 5.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (empty)\u003c\/th\u003e\n\u003ctd\u003e1.5 kg (3.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDelivered as\u003c\/th\u003e\n\u003ctd\u003eEmpty case, without the devices shown in product photographs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe case ships empty. The analyser, power supply, cables and accessories in OMICRON Lab's photographs are not included.\u003c\/li\u003e\n  \u003cli\u003eCapacity is the analyser plus up to four accessories. A larger accessory set needs separate storage.\u003c\/li\u003e\n  \u003cli\u003eNo shell material, ingress rating or drop rating is published.\u003c\/li\u003e\n  \u003cli\u003eFor a fixed bench or test-rack installation, the \u003ca href=\"\/es\/products\/omicron-lab-b-rmk-10-rack-mount-kit-uk\"\u003eB-RMK-10 Rack Mount Kit\u003c\/a\u003e mounts a Bode 100 in a 1U 19-inch rack slot. OMICRON Lab names only the Bode 100 for that kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCarry Case and Rack Mount Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCarrying Case E1399000\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-rmk-10-rack-mount-kit-uk\"\u003eB-RMK-10 Rack Mount Kit\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003ctd\u003eTransport and storage\u003c\/td\u003e\n\u003ctd\u003eMounting in a 1U 19-inch rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalysers named by OMICRON Lab\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500\u003c\/td\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e44.5 x 36.5 x 13.7 cm\u003c\/td\u003e\n\u003ctd\u003e48.2 x 15.2 x 4.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.5 kg (empty)\u003c\/td\u003e\n\u003ctd\u003e0.42 kg (without analyser)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalyser included\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-carrying-case-for-bode-100-uk\"\u003e£135\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-rmk-10-rack-mount-kit-uk\"\u003e£215\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eTaking a Bode 100, B-WIT 100 and voltage probes to a customer site to measure gain and phase margin on a DC\/DC converter in its real operating environment. Moving a Bode 500 with its cables and power supply between an R\u0026amp;D lab and a production test area. Keeping a shared analyser, its fixtures and power supply together on a multi-user lab shelf so the kit stays complete between jobs.\u003c\/p\u003e\n\u003cp\u003eThe case suits power electronics and test engineers who share one Bode analyser across several benches, teams or sites.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab publishes no separate box list. It states that the case is delivered without the devices shown, so the delivery is the case alone.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCarrying case with custom cut-out foam interior\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Carrying Case is \u003cspan data-ds-price=\"omicron-lab-carrying-case-for-bode-100-uk\"\u003e£135\u003c\/span\u003e ex VAT. If you are ordering an analyser at the same time, contact us for a formal quotation covering the Bode 100 or Bode 500, the case and the accessories you want to carry in it. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs the Bode Analyser Included with the Case?\u003c\/h3\u003e\n\u003cp\u003eNo. The case is delivered empty. The Bode 100 or Bode 500, its power supply, cables and any accessories are ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich Accessories Did OMICRON Lab Lay Out in the Case?\u003c\/h3\u003e\n\u003cp\u003eA B-WIT 100 injection transformer, a B-SMC and a B-WIC impedance test fixture, alongside a Bode 100, its cables and power supply. The foam takes up to four accessories in total.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/carry-case\"\u003eOMICRON Lab Carry Case for Bode 100 or Bode 500\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/shop.omicron-lab.com\/products\/bode-100-carrying-case\"\u003eOMICRON Lab Shop: Carry Case for Bode 100 \/ 500\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/rack-mount-kit\"\u003eOMICRON Lab B-RMK-10 Rack Mount Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541614858463,"sku":"E1399000","price":135.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-case-omicron-lab-carrying-case-for-bode-100-36889494192351.jpg?v=1684970751"},{"product_id":"omicron-lab-b-rfid-c-test-fixture-for-smartcards-uk","title":"OMICRON Lab B-RFID Test Fixture For RFID Cards","description":"\u003cp\u003eThe OMICRON Lab B-RFID is a test fixture for contactless resonance frequency and Q-factor measurement of RFID smart cards to ISO 14443-1:2008, with a 1 Hz to 50 MHz frequency range and a two-winding reader coil. It comes in three versions, B-RFID-A for Class 1, B-RFID-B for Class 3 and B-RFID-C for Class 6 cards, or as a set of all three. The Bode 100 acts as the reader, so RFID inlay and card designers can check transponder tuning without touching the card.\u003c\/p\u003e\n\n\u003ch2\u003eContactless Resonance Frequency and Q-Factor Measurement\u003c\/h2\u003e\n\u003cp\u003eThe B-RFID contains a reader coil and connects through one BNC input plug to the output of the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. The resonance frequency of the card corresponds to the maximum of the real part of the impedance measured at the fixture. First measure the fixture without a DUT and subtract that impedance to cancel the coil inductance. Then measure with the card fitted, narrow the frequency span and apply the Fres-Q cursor calculation. From Bode Analyzer Suite 3.11, the software calculates resonance frequency and Q-factor automatically.\u003c\/p\u003e\n\n\u003ch2\u003eRFID Test Fixture Coils Matched to Class 1, 3 and 6 Cards\u003c\/h2\u003e\n\u003cp\u003eEach version has a coil sized to its card class. The B-RFID-A coil measures 62.6 x 32.6 mm on the outer winding, the B-RFID-B 33 x 22 mm and the B-RFID-C 19 x 18 mm. Series resistance at 13.56 MHz falls from 870 mΩ (A) to 460 mΩ (C), and self-inductance from 600 nH to 230 nH, all typical. Self-resonance sits at 76 MHz, 107 MHz and 138 MHz typical, well above 13.56 MHz.\u003c\/p\u003e\n\n\u003ch2\u003eClose-Distance and 10 mm Measurements\u003c\/h2\u003e\n\u003cp\u003eA slide-in card holder positions the card either directly on the coil (close distance) or 10 mm from it. Comparing both positions shows the effect of coupling distance on the measured resonance. OMICRON Lab recommends the 0.5 m BNC cables delivered with the Bode 100 for the connection.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eContactless resonance frequency and Q-factor measurement, ISO 14443-1:2008 smart cards\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNumber of windings\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCoil size, outer winding\u003c\/th\u003e\n\u003ctd\u003eA: 62.6 x 32.6 mm; B: 33 x 22 mm; C: 19 x 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSeries resistance at 13.56 MHz (typ.)\u003c\/th\u003e\n\u003ctd\u003eA: 870 mΩ; B: 610 mΩ; C: 460 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSelf-inductance at 13.56 MHz (typ.)\u003c\/th\u003e\n\u003ctd\u003eA: 600 nH; B: 340 nH; C: 230 nH\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSelf-resonance frequency (typ.)\u003c\/th\u003e\n\u003ctd\u003eA: 76 MHz; B: 107 MHz; C: 138 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard positions\u003c\/th\u003e\n\u003ctd\u003eClose distance (on the coil) and 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eBNC input plug, to the Bode 100 output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e145 x 65 x 18.5 mm with connectors; 130 x 65 x 18.5 mm without\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.06 kg (sample card 0.01 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample card dimensions\u003c\/th\u003e\n\u003ctd\u003e85.60 x 53.98 x 0.76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-35 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20% to 80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSELV device (IEC 60950), protection class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser is not included. OMICRON Lab states the B-RFID is to be used only with the Bode 100 and\/or the \u003ca href=\"\/es\/products\/omicron-lab-b-amp-12-external-power-amplifier-uk\"\u003eB-AMP 12\u003c\/a\u003e. Its documentation does not cover the Bode 500, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eEvery version ships with a Class 1 sample card, including the Class 3 and Class 6 fixtures. Bring your own Class 3 or Class 6 cards.\u003c\/li\u003e\n  \u003cli\u003eDo not apply external voltages or currents.\u003c\/li\u003e\n  \u003cli\u003eThe fixture measures the passive resonance of the card. It does not read or write card data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-RFID Version Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-RFID-A\u003c\/th\u003e\n\u003cth\u003eB-RFID-B\u003c\/th\u003e\n\u003cth\u003eB-RFID-C\u003c\/th\u003e\n\u003cth\u003eSet (A + B + C)\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard class (ISO 14443-1:2008)\u003c\/th\u003e\n\u003ctd\u003eClass 1\u003c\/td\u003e\n\u003ctd\u003eClass 3\u003c\/td\u003e\n\u003ctd\u003eClass 6\u003c\/td\u003e\n\u003ctd\u003eClasses 1, 3 and 6\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0005774\u003c\/td\u003e\n\u003ctd\u003eP0005775\u003c\/td\u003e\n\u003ctd\u003eP0005776\u003c\/td\u003e\n\u003ctd\u003eP0005777\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCoil size, outer winding\u003c\/th\u003e\n\u003ctd\u003e62.6 x 32.6 mm\u003c\/td\u003e\n\u003ctd\u003e33 x 22 mm\u003c\/td\u003e\n\u003ctd\u003e19 x 18 mm\u003c\/td\u003e\n\u003ctd\u003eAll three\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSelf-inductance at 13.56 MHz (typ.)\u003c\/th\u003e\n\u003ctd\u003e600 nH\u003c\/td\u003e\n\u003ctd\u003e340 nH\u003c\/td\u003e\n\u003ctd\u003e230 nH\u003c\/td\u003e\n\u003ctd\u003eAll three\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample cards\u003c\/th\u003e\n\u003ctd\u003e1 x Class 1\u003c\/td\u003e\n\u003ctd\u003e1 x Class 1\u003c\/td\u003e\n\u003ctd\u003e1 x Class 1\u003c\/td\u003e\n\u003ctd\u003e3 x Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-rfid-c-test-fixture-for-smartcards-uk\"\u003e£150\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-rfid-c-test-fixture-for-smartcards-uk\"\u003e£150\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-rfid-c-test-fixture-for-smartcards-uk\"\u003e£150\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSelect the Set option above for its price\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eTuning a Class 1 card inlay during antenna design. Incoming inspection of Class 3 or Class 6 transponders, checking resonance frequency and Q-factor against the supplier's tolerance. Comparing close-distance and 10 mm results to see how coupling distance moves the measured resonance.\u003c\/p\u003e\n\u003cp\u003eThe B-RFID suits RFID hardware engineers who own a Bode 100 and need repeatable card measurements without building their own reader coil.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-RFID-A (Class 1): B-RFID-A test fixture and one Class 1 sample card\u003c\/li\u003e\n  \u003cli\u003eB-RFID-B (Class 3): B-RFID-B test fixture and one Class 1 sample card\u003c\/li\u003e\n  \u003cli\u003eB-RFID-C (Class 6): B-RFID-C test fixture and one Class 1 sample card\u003c\/li\u003e\n  \u003cli\u003eSet: B-RFID-A, B-RFID-B and B-RFID-C test fixtures and three Class 1 sample cards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSingle OMICRON Lab B-RFID fixtures are \u003cspan data-ds-price=\"omicron-lab-b-rfid-c-test-fixture-for-smartcards-uk\" data-ds-prefix=\"from \"\u003efrom £150\u003c\/span\u003e ex VAT. Tell us your card class if you are unsure which version fits, or contact us for a formal quotation covering the Bode 100 and fixtures. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich B-RFID Version Do I Need?\u003c\/h3\u003e\n\u003cp\u003eMatch the fixture to the card class under ISO 14443-1:2008: B-RFID-A for Class 1, B-RFID-B for Class 3, B-RFID-C for Class 6. If you test several classes, the set holds all three fixtures.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eDoes the B-RFID Work with the Bode 500?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab's B-RFID documentation names only the Bode 100 and the B-AMP 12. Contact us before ordering if your analyser is a Bode 500.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eDoes the Software Calculate Q-Factor Automatically?\u003c\/h3\u003e\n\u003cp\u003eYes, from Bode Analyzer Suite 3.11 the software calculates the resonance frequency and Q-factor automatically. Measure and subtract the empty fixture first, as the user manual describes.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (4 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-rfid-test-fixtures\"\u003eOMICRON Lab B-RFID Test Fixtures\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/applications\/detail\/news\/rfid-resonance-frequency-measurement\"\u003eOMICRON Lab Application: RFID Resonance Frequency Measurement\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-rfid-a-test-fixture-for-class-1-cards\"\u003eOMICRON Lab Shop: B-RFID-A Test Fixture for Class 1 Cards\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-rfid-test-fixture-set\"\u003eOMICRON Lab Shop: B-RFID Test Fixture Set\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Class 1","offer_id":42541663092959,"sku":"P0005774","price":150.0,"currency_code":"GBP","in_stock":true},{"title":"Class 3","offer_id":42541663125727,"sku":"P0005775","price":150.0,"currency_code":"GBP","in_stock":true},{"title":"Class 6","offer_id":42541663158495,"sku":"P0005776","price":150.0,"currency_code":"GBP","in_stock":true},{"title":"Set (one of each class)","offer_id":42649764102367,"sku":"P0005777","price":350.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-test-fixture-class-3-omicron-lab-b-rfid-test-fixture-for-type-1-rfid-cards-36889478004959.jpg?v=1684965163"},{"product_id":"omicron-lab-b-cal-3-calibration-board-set-uk","title":"OMICRON Lab B-CAL-3 Calibration Board Set","description":"\u003cp\u003eThe OMICRON Lab B-CAL-3 Calibration Board Set is three replacement calibration boards for the B-WIC impedance test fixture, each carrying a gold-coated short and a 100 Ω load with 0.1% accuracy and a 15 ppm\/°C temperature coefficient. Each board provides the Short and Load references for Open, Short and Load calibration of a B-WIC on the Bode 100. Engineers measuring leaded passives keep a set on the bench so a worn or contaminated board never limits a low-impedance measurement.\u003c\/p\u003e\n\n\u003ch2\u003eGold-Coated Short and 100 Ω Precision Load\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab credits the gold coating and the high-precision load for reproducible Open, Short and Load calibrations. The load side is 100 Ω with 0.1% accuracy and a temperature coefficient of 15 ppm\/°C, the same value the B-WIC and B-SMC user manual lists for the B-CAL-3 load. The short side measures approx. under 100 mΩ DC resistance in OMICRON Lab's functional check. The boards come as a set of three, so a spare is ready when one wears.\u003c\/p\u003e\n\n\u003ch2\u003eOpen, Short and Load Calibration of the B-WIC\u003c\/h2\u003e\n\u003cp\u003eCalibration is required before measuring with the \u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e. Open is run with no DUT fitted. For Short, insert the short side of the B-CAL-3 into the electrode slots. For Load, turn the board round and insert the load side. The Bode Analyzer Suite then corrects the fixture in the Impedance Adapter measurement mode on the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e. Measurement accuracy depends on these calibration elements and on clean contacts. The B-WIC electrodes reach a contact resistance of around 0.5 mΩ, so a clean short matters at the 20 mΩ low end of the recommended impedance range.\u003c\/p\u003e\n\n\u003ch2\u003eChecking a Calibration Board with a Multimeter\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab's B-WIC and B-SMC functional check starts with the B-CAL-3 itself. Measure the DC resistance on the load side: the expected value is 100 Ω. Measure the DC resistance and continuity on the short side: the expected value is approx. under 100 mΩ. A board that reads outside these values should be replaced before you calibrate the fixture.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eReplacement calibration element for the B-WIC impedance test fixture\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibration references\u003c\/th\u003e\n\u003ctd\u003eShort side and load side on each board\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLoad value\u003c\/th\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLoad accuracy\u003c\/th\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLoad temperature coefficient\u003c\/th\u003e\n\u003ctd\u003e15 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eExpected short-side DC resistance\u003c\/th\u003e\n\u003ctd\u003eApprox. \u0026lt; 100 mΩ (functional check)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContact finish\u003c\/th\u003e\n\u003ctd\u003eGold coating\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003ctd\u003e3 boards per set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOMICRON Lab lists the B-CAL-3 as the calibration element for the B-WIC. The \u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e calibrates with a 100 Ω 0603 resistor between its needle and electrode, and six such resistors ship with it.\u003c\/li\u003e\n  \u003cli\u003eOne B-CAL calibration board already ships with every B-WIC. Order this set as a spare or replacement.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab publishes no dimensions or weight for the board.\u003c\/li\u003e\n  \u003cli\u003eThe board provides Short and Load only. Open calibration is run with the fixture empty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCalibration Options Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-CAL-3 Set\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWhat it is\u003c\/th\u003e\n\u003ctd\u003e3 calibration boards\u003c\/td\u003e\n\u003ctd\u003eImpedance test fixture, wired (through-hole)\u003c\/td\u003e\n\u003ctd\u003eImpedance test fixture, surface-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibration items supplied\u003c\/th\u003e\n\u003ctd\u003e3 x B-CAL-3 board\u003c\/td\u003e\n\u003ctd\u003eB-CAL calibration board (1 pc.)\u003c\/td\u003e\n\u003ctd\u003e6 x 0603 load resistors, 100 Ω ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLoad reference\u003c\/th\u003e\n\u003ctd\u003e100 Ω, 0.1%, 15 ppm\/°C\u003c\/td\u003e\n\u003ctd\u003e100 Ω (B-CAL board)\u003c\/td\u003e\n\u003ctd\u003e100 Ω ±0.1%, 15 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUsable frequency range\u003c\/th\u003e\n\u003ctd\u003eSet by the B-WIC: 1 Hz to 50 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-cal-3-calibration-board-set-uk\"\u003e£105\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eReplacing the B-CAL board supplied with a B-WIC once its gold contacts show wear. Keeping separate calibration boards for several B-WIC fixtures in a test lab. Recalibrating before low-value measurements such as capacitor ESR, where the short reference sets the measurement floor.\u003c\/p\u003e\n\u003cp\u003eThe set suits labs that use a B-WIC daily and want a known-good calibration reference on hand.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-CAL-3 calibration board (3 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-CAL-3 Calibration Board Set is \u003cspan data-ds-price=\"omicron-lab-b-cal-3-calibration-board-set-uk\"\u003e£105\u003c\/span\u003e ex VAT. Add it to a B-WIC order, or contact us for a formal quotation covering the Bode 100, fixture and spares. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs a Calibration Board Already Included with the B-WIC?\u003c\/h3\u003e\n\u003cp\u003eYes. Each B-WIC ships with one B-CAL calibration board. The B-CAL-3 set gives you three more, as spares or replacements.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eCan I Use the B-CAL-3 with the B-SMC?\u003c\/h3\u003e\n\u003cp\u003eNo. OMICRON Lab sells the B-CAL-3 as the calibration element for the B-WIC. The B-SMC uses its needle closed onto the electrode for Short and a 100 Ω 0603 resistor for Load; six resistors (100 Ω ±0.1%) come with it.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eHow Do I Know When a Board Needs Replacing?\u003c\/h3\u003e\n\u003cp\u003eMeasure it with a multimeter. OMICRON Lab expects 100 Ω on the load side and approx. under 100 mΩ on the short side. A board outside these values, or one with visibly worn contacts, should be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/shop.omicron-lab.com\/products\/b-cal-3-calibration-board\"\u003eOMICRON Lab Shop: B-CAL-3 Calibration Board Set\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/impedance-test-fixtures-b-wic-b-smc\"\u003eOMICRON Lab Impedance Test Fixtures B-WIC and B-SMC\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541669908703,"sku":"P0005779","price":105.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-test-fixture-omicron-lab-b-cal-3-calibration-board-set-36889476595935.jpg?v=1684966082"},{"product_id":"omicron-lab-b-rmk-10-rack-mount-kit-uk","title":"OMICRON Lab B-RMK-10 Rack Mount Kit","description":"\u003cp\u003eThe OMICRON Lab B-RMK-10 Rack Mount Kit is a stainless-steel kit that mounts a Bode 100 vector network analyser in a 1U slot of a 19-inch rack. It consists of a front panel, left and right rails, six M4 and two M3 screws, weighs 0.42 kg without the instrument and the manual specifies a TX10 screwdriver for the Bode 100 front-panel screws. Test engineers use it to build the Bode 100 into automated test racks and production test stations.\u003c\/p\u003e\n\n\u003ch2\u003e1U 19-Inch Rack Mounting for the Bode 100\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab specifies the B-RMK-10 as a stainless-steel mount kit that holds a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e in a single 1U slot of a 19-inch rack. The kit measures 48.2 x 15.2 x 4.4 cm (19 x 5.96 x 1.72 in) and weighs 0.42 kg without the instrument. Once fitted, the Bode 100 can share a rack with the power supplies, loads and switching units of a test system.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation with a TX10 Screwdriver\u003c\/h2\u003e\n\u003cp\u003eThe user manual sets out five steps. Unplug all cables and connections from the Bode 100 first. With a TX10 screwdriver, loosen the two screws on the left and right of the front panel and remove the plastic frame. Fix the left and right rails to the B-RMK-10 front panel with the six short M4 countersunk screws. Attach the assembled kit to the instrument with the two M3 countersunk screws. Where rack height is tight, remove the four rubber feet from the bottom of the Bode 100, again with the TX10.\u003c\/p\u003e\n\n\u003ch2\u003eBuilt for Test Racks and Production Stations\u003c\/h2\u003e\n\u003cp\u003eA rack-mounted Bode 100 suits fixed setups where the analyser stays wired to fixtures, injection transformers and switching hardware between runs. Typical companions on the bench or in the rack include the \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e for loop gain and the \u003ca href=\"\/es\/products\/omicron-lab-b-amp-12-external-power-amplifier-uk\"\u003eB-AMP 12\u003c\/a\u003e amplifier. For an analyser that moves between labs, the carrying case is the alternative.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRack standard\u003c\/th\u003e\n\u003ctd\u003e19-inch rack, 1U slot\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e48.2 x 15.2 x 4.4 cm (19 x 5.96 x 1.72 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (kit without device)\u003c\/th\u003e\n\u003ctd\u003e0.42 kg (0.94 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFixings\u003c\/th\u003e\n\u003ctd\u003e6 x M4 countersunk screws, 2 x M3 countersunk screws\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTool required\u003c\/th\u003e\n\u003ctd\u003eTX10 screwdriver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe Bode 100 is not included. OMICRON Lab states the kit is delivered without the instrument.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab documents the B-RMK-10 for the Bode 100 only. It does not list the Bode 500, so ask us before ordering for a Bode 500.\u003c\/li\u003e\n  \u003cli\u003eNo rack slides or rear supports are listed in the kit contents.\u003c\/li\u003e\n  \u003cli\u003eRemoving the rubber feet is only needed where height is limited. Keep them if the Bode 100 will go back on the bench.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Housing Options Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-RMK-10 Rack Mount Kit\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-carrying-case-for-bode-100-uk\"\u003eCarrying Case for Bode 100 and Bode 500\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eFixed 1U mounting in a 19-inch rack\u003c\/td\u003e\n\u003ctd\u003eTransport and storage, custom cut-out foam interior\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003ctd\u003eBode 100 or Bode 500, with cables, power supply and up to 4 accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e48.2 x 15.2 x 4.4 cm\u003c\/td\u003e\n\u003ctd\u003e44.5 x 36.5 x 13.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.42 kg (without analyser)\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (empty)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-rmk-10-rack-mount-kit-uk\"\u003e£215\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-carrying-case-for-bode-100-uk\"\u003e£135\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eIntegrating a Bode 100 into a 19-inch automated test rack for end-of-line loop gain or impedance checks on power supplies. Mounting the analyser in a shared lab rack so bench space stays clear. Building a fixed RFID or component test station around the Bode 100 and its fixtures.\u003c\/p\u003e\n\u003cp\u003eThe B-RMK-10 suits test engineers who run the Bode 100 in one place and want it secured in standard rack hardware.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFront panel (1 pc.)\u003c\/li\u003e\n  \u003cli\u003eLeft rail (1 pc.)\u003c\/li\u003e\n  \u003cli\u003eRight rail (1 pc.)\u003c\/li\u003e\n  \u003cli\u003eM4 screws (6 pcs.)\u003c\/li\u003e\n  \u003cli\u003eM3 screws (2 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-RMK-10 Rack Mount Kit is \u003cspan data-ds-price=\"omicron-lab-b-rmk-10-rack-mount-kit-uk\"\u003e£215\u003c\/span\u003e ex VAT. Contact us for a formal quotation if you are building a complete Bode 100 test rack. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the B-RMK-10 Fit the Bode 500?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab documents the B-RMK-10 for the Bode 100 only and does not list the Bode 500. Contact us before ordering if your analyser is a Bode 500.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat Tools Do I Need to Fit It?\u003c\/h3\u003e\n\u003cp\u003eThe manual names a TX10 screwdriver. It removes the front panel screws and plastic frame of the Bode 100 and, where needed, the four rubber feet. The rails, front panel and screws come in the kit.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eHow Much Rack Space Does It Take?\u003c\/h3\u003e\n\u003cp\u003eOne 1U slot in a 19-inch rack. Remove the rubber feet from the Bode 100 if height is limited.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/rack-mount-kit\"\u003eOMICRON Lab B-RMK-10 Rack Mount Kit\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/b-rmk-10-rack-mount-kit\"\u003eOMICRON Lab Shop: B-RMK-10 Rack Mount Kit\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/bode-100-carrying-case\"\u003eOMICRON Lab Shop: Carry Case for Bode 100 \/ 500\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42541689274591,"sku":"P0001108","price":215.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-omicron-lab-b-rmk-10-rack-mount-kit-36889487245535.jpg?v=1684965900"},{"product_id":"omicron-lab-pml111o-passive-10-1-probe-uk","title":"OMICRON Lab PML111O Passive 10:1 Probe","description":"\u003cp\u003eThe OMICRON Lab PML 111O is a passive 10:1 probe made by PMK and optimised for the Bode 100, with 1 MΩ || 12.5 pF input impedance, 50 MHz system bandwidth and a 2.5 mm probe tip. Its voltage divider sits in the probe tip, so it divides DC correctly into the Bode 100's ac-coupled inputs and protects them. Power supply designers use a pair of them for loop gain and stability measurements on DC\/DC converters and voltage regulators.\u003c\/p\u003e\n\n\u003ch2\u003eWhy the Bode 100 Needs a Matched 10:1 Probe\u003c\/h2\u003e\n\u003cp\u003eThe Bode 100 inputs are ac-coupled. OMICRON Lab warns that a standard oscilloscope probe does not divide DC signals as expected on these inputs and can damage the analyser. The PML 111O places the divider in the probe tip, so the whole signal, DC included, is divided before it reaches the input channel. OMICRON Lab recommends it for highly accurate loop gain measurements and for reducing capacitive loading on the circuit under test.\u003c\/p\u003e\n\n\u003ch2\u003ePassive 10:1 Probe Specifications for Loop Gain Work\u003c\/h2\u003e\n\u003cp\u003eAttenuation is 10:1 ±2% at DC, system input resistance is 1 MΩ ±1% and input capacitance is 12.5 pF. System bandwidth is 50 MHz (passband, under -1 dB) and rise time is 7 ns, which covers the Bode 100's 1 Hz to 50 MHz range. Each probe is pre-compensated in production, and the compensation range of 40 pF to 55 pF lets you fine-tune it to the instrument input. Cable length is 1.3 m and the probe weighs 48 g.\u003c\/p\u003e\n\n\u003ch2\u003eVoltage Ratings and Safe Use\u003c\/h2\u003e\n\u003cp\u003eThe probe is rated 400 V rms in measurement category I, with 1250 V transient overvoltage, and 300 V rms in CAT II. The maximum input voltage falls as signal frequency rises; the derating curve is in the manual. The ground lead is for earth ground only, so the PML 111O is not a floating or differential probe. For off-line power stages or higher bus voltages, choose the \u003ca href=\"\/es\/products\/omicron-lab-phv-1000-o-high-voltage-probe\"\u003ePHV 1000-O\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e10:1 ±2% at DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem bandwidth\u003c\/th\u003e\n\u003ctd\u003e50 MHz (passband, \u0026lt; -1 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRise time\u003c\/th\u003e\n\u003ctd\u003e7 ns (10% to 90%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput resistance (system)\u003c\/th\u003e\n\u003ctd\u003e1 MΩ ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput capacitance (system)\u003c\/th\u003e\n\u003ctd\u003e12.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e40 pF to 55 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage coefficient\u003c\/th\u003e\n\u003ctd\u003e0.00025%\/V at DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, CAT I\u003c\/th\u003e\n\u003ctd\u003e400 V rms (1250 V transient overvoltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, CAT II\u003c\/th\u003e\n\u003ctd\u003e300 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNon-operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +71 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating altitude\u003c\/th\u003e\n\u003ctd\u003eUp to 2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC 61010-031:2008, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eThe maximum input voltage derates with frequency. Check the curve in the manual before probing fast, high-amplitude nodes.\u003c\/li\u003e\n  \u003cli\u003eThe supplied BNC adapter is rated 42 V peak (AC + DC), well below the probe's own rating.\u003c\/li\u003e\n  \u003cli\u003eConnect the ground lead to earth ground only. It is not for floating measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Passive Probe Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003ePML 111O\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-phv-1000-o-high-voltage-probe\"\u003ePHV 1000-O\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance (system)\u003c\/th\u003e\n\u003ctd\u003e1 MΩ || 12.5 pF\u003c\/td\u003e\n\u003ctd\u003e50 MΩ || 7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem bandwidth\u003c\/th\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by OMICRON Lab or PMK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e400 V rms CAT I, 300 V rms CAT II\u003c\/td\u003e\n\u003ctd\u003e2000 V peak (no measurement category), 1000 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e40 pF to 55 pF\u003c\/td\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.3 m\u003c\/td\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBNC adapter in the box\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo (optional PMK accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-pml111o-passive-10-1-probe-uk\"\u003e£235\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eLoop gain and phase margin measurement on a DC\/DC converter with a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e and a \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e, with one probe on each side of the injection resistor. Stability checks on linear regulators where the 12.5 pF input capacitance keeps loading of the feedback node low. Slow control loops such as PFC regulators, measured down to 1 Hz with the \u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e injection transformer.\u003c\/p\u003e\n\u003cp\u003eThe PML 111O suits Bode 100 owners measuring control loops at board-level voltages.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePML 111O probe with gold-plated 0.5 mm spring tip (fitted) and protection cap\u003c\/li\u003e\n  \u003cli\u003eSolid probe tip, CuBe 0.5 mm\u003c\/li\u003e\n  \u003cli\u003eGround lead, 15 cm\u003c\/li\u003e\n  \u003cli\u003eGround spring contact\u003c\/li\u003e\n  \u003cli\u003eSprung hook\u003c\/li\u003e\n  \u003cli\u003eBNC adapter\u003c\/li\u003e\n  \u003cli\u003eIsolation cap\u003c\/li\u003e\n  \u003cli\u003ePCB adapter kit\u003c\/li\u003e\n  \u003cli\u003eColour-coding rings (3 each of 4 colours)\u003c\/li\u003e\n  \u003cli\u003ePrinted user manual in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab PML 111O is \u003cspan data-ds-price=\"omicron-lab-pml111o-passive-10-1-probe-uk\"\u003e£235\u003c\/span\u003e ex VAT. A loop gain setup takes two probes, so check how many you need, or contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan I Use a Standard Oscilloscope Probe with the Bode 100 Instead?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab advises against it. The Bode 100 inputs are ac-coupled, so a standard probe does not divide DC as expected and can damage the input. The PML 111O puts the divider in the tip to avoid this.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eHow Many Probes Do I Need for a Loop Gain Measurement?\u003c\/h3\u003e\n\u003cp\u003eTwo. One probe measures each side of the injection resistor, and the Bode 100 calculates loop gain from the ratio of the two channels.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat Is the Maximum Voltage I Can Measure?\u003c\/h3\u003e\n\u003cp\u003e400 V rms in CAT I or 300 V rms in CAT II, derated with frequency. Above that, use the PHV 1000-O, rated 2000 V peak with no measurement category and 1000 V CAT II.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/passive-probes\"\u003eOMICRON Lab Passive Probes PML 111O and PHV 1000-O\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/shop.omicron-lab.com\/products\/pml-111o-passive-probe\"\u003eOMICRON Lab Shop: PML 111O High Impedance Passive Probe 10:1\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":42703881109727,"sku":"B1666600","price":235.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/omicron-lab-network-analyser-accessory-omicron-lab-pml111o-passive-10-1-probe-37002954408159.jpg?v=1684964282"},{"product_id":"omicron-lab-phv-1000-o-high-voltage-probe","title":"OMICRON Lab PHV 1000-O High-Voltage Passive 100:1 Probe","description":"\u003cp\u003eThe OMICRON Lab PHV 1000-O is a high-voltage passive 100:1 probe made by PMK for the Bode 100, rated 2000 V peak with no measurement category and 1000 V CAT II, with 50 MΩ || 7.5 pF input impedance and a 5 mm probe tip. It is based on PMK's PHV high-voltage series and designed for the Bode 100's 1 MΩ ac-coupled inputs. Power electronics engineers use it for loop gain measurements on converters running at bus voltages beyond the reach of a 10:1 probe.\u003c\/p\u003e\n\n\u003ch2\u003eLoop Gain Measurement at Higher Voltages\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab recommends the PHV 1000-O for accurate loop gain measurements at higher voltages and for protecting the Bode 100 input channels. Like the PML 111O, it keeps the divider in the probe rather than relying on the analyser input. The Bode 100 inputs are ac-coupled, and OMICRON Lab warns that a standard oscilloscope probe can damage them. PMK's manual still asks you to check the Bode 100's maximum permissible signal levels and fit suitable attenuators if necessary.\u003c\/p\u003e\n\n\u003ch2\u003e100:1 Probe Ratings and Derating\u003c\/h2\u003e\n\u003cp\u003eSystem input resistance is 50 MΩ ±1% and input capacitance is 7.5 pF, so loading of a high-impedance feedback node is lower than with a 10:1 probe. The compensation range is 10 pF to 50 pF, set with the supplied adjustment tool. Maximum input voltage is 2000 V peak (DC or AC peak) outside any measurement category and 1000 V in CAT II, both at pollution degree 2. The permitted voltage falls as frequency rises; the derating curve is in the manual. Neither OMICRON Lab nor PMK publishes a bandwidth figure for this probe.\u003c\/p\u003e\n\n\u003ch2\u003eSafe Connection to High-Voltage Circuits\u003c\/h2\u003e\n\u003cp\u003eConnect the probe ground to earth before the tip touches the test point, and remove the tip before disconnecting the probe from the instrument. Use the ground lead for earth ground only, so this is not a floating or differential probe, and use only grounded measuring instruments. When the probe is combined with an accessory, the lower of the two ratings applies.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput resistance (system)\u003c\/th\u003e\n\u003ctd\u003e50 MΩ ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput capacitance (system)\u003c\/th\u003e\n\u003ctd\u003e7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInstrument input coupling\u003c\/th\u003e\n\u003ctd\u003e1 MΩ AC (Bode 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, no measurement category\u003c\/th\u003e\n\u003ctd\u003e2000 V peak (DC or AC peak), pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage, CAT II\u003c\/th\u003e\n\u003ctd\u003e1000 V, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNon-operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C to +71 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating humidity\u003c\/th\u003e\n\u003ctd\u003e80% RH up to +31 °C, decreasing linearly to 40% at +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating altitude\u003c\/th\u003e\n\u003ctd\u003eUp to 2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety standard\u003c\/th\u003e\n\u003ctd\u003eIEC 61010-031\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePMK order number\u003c\/th\u003e\n\u003ctd\u003e860-512-O00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eNo bandwidth or rise time is published. If you need a stated 50 MHz bandwidth at board-level voltages, the \u003ca href=\"\/es\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e is specified for it.\u003c\/li\u003e\n  \u003cli\u003eThe maximum input voltage derates with frequency. Check the curve before probing fast switching nodes.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab names only the Bode 100 for this probe. The Bode 500 uses N-type connectors where the Bode 100 uses BNC, so ask us before ordering for a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eA BNC adapter 5.0-L is an optional PMK accessory and is not in the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Passive Probe Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-pml111o-passive-10-1-probe-uk\"\u003ePML 111O\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003ePHV 1000-O\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAttenuation\u003c\/th\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003ctd\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInput impedance (system)\u003c\/th\u003e\n\u003ctd\u003e1 MΩ || 12.5 pF\u003c\/td\u003e\n\u003ctd\u003e50 MΩ || 7.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSystem bandwidth\u003c\/th\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003eNot stated by OMICRON Lab or PMK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. input voltage\u003c\/th\u003e\n\u003ctd\u003e400 V rms CAT I, 300 V rms CAT II\u003c\/td\u003e\n\u003ctd\u003e2000 V peak (no measurement category), 1000 V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompensation range\u003c\/th\u003e\n\u003ctd\u003e40 pF to 55 pF\u003c\/td\u003e\n\u003ctd\u003e10 pF to 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProbe tip diameter\u003c\/th\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable length\u003c\/th\u003e\n\u003ctd\u003e1.3 m\u003c\/td\u003e\n\u003ctd\u003e1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight (probe only)\u003c\/th\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBNC adapter in the box\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo (optional PMK accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-pml111o-passive-10-1-probe-uk\"\u003e£235\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eLoop gain and phase margin measurement on an off-line converter with a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e and a \u003ca href=\"\/es\/products\/omicron-lab-b-wit-100-wideband-injection-transformer-uk\"\u003eB-WIT 100\u003c\/a\u003e, whose 600 V CAT II isolation lets the injection point sit at high potential. Stability measurement on slow PFC control loops with the \u003ca href=\"\/es\/products\/omicron-lab-b-lft-100-low-frequency-injection-transformer-uk\"\u003eB-LFT 100\u003c\/a\u003e. Probing high-impedance feedback nodes where the 50 MΩ input resistance keeps DC loading low.\u003c\/p\u003e\n\u003cp\u003eThe PHV 1000-O suits Bode 100 owners measuring control loops above the PML 111O's 300 V rms CAT II rating.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePHV 1000-O probe with 0.8 mm spring tip (fitted) and protection cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eSolid probe tip, CuBe 0.8 mm\u003c\/li\u003e\n  \u003cli\u003eGround lead, 22 cm\u003c\/li\u003e\n  \u003cli\u003eSprung hook 5.0-L\u003c\/li\u003e\n  \u003cli\u003eInsulating cap 5.0-L\u003c\/li\u003e\n  \u003cli\u003eAdjustment tool T\u003c\/li\u003e\n  \u003cli\u003ePrinted user manual in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab PHV 1000-O is \u003cspan data-ds-price=\"omicron-lab-phv-1000-o-high-voltage-probe\"\u003e£535\u003c\/span\u003e ex VAT. Contact us for a formal quotation covering the Bode 100, injection transformer and probes. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat Does 2000 V Peak with No Measurement Category Mean?\u003c\/h3\u003e\n\u003cp\u003eIt is PMK's rating for measurements that are not in CAT II, III or IV, at pollution degree 2. Where CAT II applies, the limit is 1000 V. Both ratings fall as frequency rises, following the derating curve in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eShould I Choose the PHV 1000-O or the PML 111O?\u003c\/h3\u003e\n\u003cp\u003eChoose the PML 111O for board-level loops up to 300 V rms CAT II, where its 50 MHz bandwidth and 2.5 mm tip help. Choose the PHV 1000-O when the node you probe exceeds that rating.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/passive-probes\"\u003eOMICRON Lab Passive Probes PML 111O and PHV 1000-O\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/injection-transformer\"\u003eOMICRON Lab Injection Transformers B-WIT and B-LFT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":44340939555039,"sku":"P0008137","price":535.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0008137-40398157938911.jpg?v=1693649635"},{"product_id":"omicron-lab-bode-500-vector-network-analyser-vna","title":"OMICRON Lab Bode 500 Vector Network Analyser (VNA)","description":"\u003c!-- Introduction --\u003e\n\u003cheader\u003e\n\u003ch1\u003eVector Network Analyzer - Bode 500\u003c\/h1\u003e\n\u003c\/header\u003e\n\u003c!-- Overview --\u003e\n\n\u003csection\u003e\n\u003cdiv class=\"overview\"\u003e\n\u003cp\u003eThe Bode 500 is the most powerful analyzer from OMICRON Lab. Its ultra-wide frequency range enables precise measurements from 10 mHz to 450 MHz, making it the perfect tool for power integrity verifications and loop stability measurements.\u003c\/p\u003e\n\n\u003cp\u003eThe Bode 500 offers high linearity and a high dynamic range of \u0026gt; 120 dB to enable accurate vector network analysis, frequency response analysis, and impedance measurements. The switchable inputs provide 50 Ω termination and a high impedance setting with ac-coupled 1 MΩ for measurements on active systems and the use with external probes.\u003c\/p\u003e\n\n\u003cp\u003eWith 66 dB of dynamic range on the output and a maximum power level of 16 dBm, the analyzer offers enough signal injection power for loop gain and output impedance measurements on switching converters and power distribution networks (PDN).\u003c\/p\u003e\n\n\u003cp\u003eThe Bode 500 is a silent, fanless, portable instrument that can be powered by Ethernet (PoE), USB (USB-PD), or a standard power supply. The analyzer offers a USB-C and an Ethernet interface for connection to the network or the control computer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"image\"\u003e\u003cimg alt=\"Bode 500 Vector Network Analyzer\" data-entity-type=\"\" data-entity-uuid=\"\" height=\"345\" src=\"https:\/\/www.omicron-lab.com\/fileadmin\/_processed_\/bode-500-image.jpg\" width=\"500\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\n\u003csection\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\n\u003cdiv class=\"key-features\"\u003e\n\u003cp\u003eThe Bode 500 offers a range of key features that make it the perfect tool for power integrity verifications and loop stability measurements:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eUltra-wide frequency range from 10 mHz to 450 MHz\u003c\/li\u003e\n\t\u003cli\u003eHigh linearity and high dynamic range of \u0026gt; 120 dB\u003c\/li\u003e\n\t\u003cli\u003eSwitchable inputs with 50 Ω termination and high impedance setting\u003c\/li\u003e\n\t\u003cli\u003e66 dB of dynamic range on the output and maximum power level of 16 dBm\u003c\/li\u003e\n\t\u003cli\u003eSilent, fanless, portable instrument with USB-C and Ethernet interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\n\u003csection\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\n\u003cdiv class=\"applications\"\u003e\n\u003cp\u003eThe Bode 500 is the perfect tool for a range of applications, including:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003ePower integrity verifications and loop stability measurements\u003c\/li\u003e\n\t\u003cli\u003eVector network analysis and frequency response analysis\u003c\/li\u003e\n\t\u003cli\u003eImpedance measurements and S-parameter measurements\u003c\/li\u003e\n\t\u003cli\u003eStability assessment of control loops and determination of resonance frequencies\u003c\/li\u003e\n\t\u003cli\u003eImpedance measurement of inductors, capacitors, and resistors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Technical Specifications --\u003e\n\n\u003csection\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003cdiv class=\"technical-specifications\"\u003e\n\u003ctable style=\"width: 322px;\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth style=\"width: 163px;\"\u003eCharacteristic\u003c\/th\u003e\n\t\t\t\u003cth style=\"width: 111px;\"\u003eBode 500\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003eFrequency range\u003c\/td\u003e\n\t\t\t\u003ctd style=\"width: 111px;\"\u003e10 mHz to 450 MHz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003eDynamic range\u003c\/td\u003e\n\t\t\t\u003ctd style=\"width: 111px;\"\u003e\u0026gt; 120 dB\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003eSignal source\u003c\/td\u003e\n\t\t\t\u003ctd style=\"width: 111px;\"\u003e-50 dBm to 16 dBm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003eConnector type\u003c\/td\u003e\n\t\t\t\u003ctd style=\"width: 111px;\"\u003eType N\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003eSource impedance\u003c\/td\u003e\n\t\t\t\u003ctd style=\"width: 111px;\"\u003e50 Ω\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"width: 163px;\"\u003e \u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":44717793542367,"sku":"P0009652","price":13910.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0009652-omicron-lab-bode-500-vector-network-analyser-bode-500-43329592361183.png?v=1723762903"},{"product_id":"omicron-lab-dsh-100-dielectric-sample-holder","title":"OMICRON-Lab DSH 100 Dielectric Sample Holder","description":"\u003cp\u003eThe OMICRON Lab DSH 100 is a dielectric sample holder for solid insulating materials, with a guarded parallel plate electrode system usable from 5 µHz to 5 MHz at up to 200 V peak. It takes samples 0.1 mm to 20 mm thick and 50 x 50 mm to 70 x 70 mm, and operates from -55 °C to +125 °C. Materials and insulation engineers use it with a Bode 100, impedance analyser or LCR meter to measure polymers, epoxy resins, insulation papers, glasses and thin films to ASTM D150 and IEC 62631-2-1.\u003c\/p\u003e\n\n\u003ch2\u003eGuarded Parallel Plate Electrodes for Solid Dielectrics\u003c\/h2\u003e\n\u003cp\u003eThe top (IN) electrode is a 70 mm diameter PCB disc. The bottom (MEAS) electrode is 49 mm in diameter and surrounded by a 9.5 mm guard ring with a 1 mm gap. The electrodes are exchangeable and low cost, which OMICRON Lab notes makes it practical to analyse curing processes, for example in epoxy systems. Two 0.3 mm and two 0.8 mm spacers are supplied for air-reference measurements.\u003c\/p\u003e\n\n\u003ch2\u003eControlled Clamping and Temperature Testing\u003c\/h2\u003e\n\u003cp\u003eA tensioner controls the pressure force on the sample, with 50 N and 100 N spring systems supplied. The housing has mounting provision for a heating pad, a pressure sensor and a temperature sensor (not supplied), and the holder operates from -55 °C to +125 °C at up to 95% relative humidity, non-condensing. OMICRON Lab warns that the metal surface must not be touchable while operating above 65 °C.\u003c\/p\u003e\n\n\u003ch2\u003eConnecting the Dielectric Sample Holder to an Analyser\u003c\/h2\u003e\n\u003cp\u003eThe DSH 100 connects through a triaxial LEMO interface (female plug PSA.1S.650.CLL). MEAS goes to the analyser input and IN to the analyser output. The \u003ca href=\"\/es\/products\/omicron-lab-triaxial-to-bnc-adapter-cable\"\u003eTriaxial to BNC Adapter Cable\u003c\/a\u003e (B1023000) connects it to the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or any LCR meter with BNC connections. Use only a signal source that provides a galvanically isolated (floating) voltage, stay within 200 V peak and 50 mA peak, and connect the grounding terminal to laboratory earth. A safety interlock stops the holder opening while a cable is connected.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage (AC\/DC)\u003c\/th\u003e\n\u003ctd\u003e≤ 200 V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. current (AC\/DC)\u003c\/th\u003e\n\u003ctd\u003e≤ 50 mA peak\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eTriaxial, LEMO female plug PSA.1S.650.CLL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample thickness\u003c\/th\u003e\n\u003ctd\u003e0.1 mm to 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSample size\u003c\/th\u003e\n\u003ctd\u003e50 x 50 mm to 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTop electrode\u003c\/th\u003e\n\u003ctd\u003eØ 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBottom electrode (with guard ring)\u003c\/th\u003e\n\u003ctd\u003eØ 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGuard ring width \/ gap\u003c\/th\u003e\n\u003ctd\u003e9.5 mm \/ 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpacers (air reference)\u003c\/th\u003e\n\u003ctd\u003e2 x 0.8 mm, 2 x 0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpring force (clamping system)\u003c\/th\u003e\n\u003ctd\u003e50 N and 100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-55 °C to +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e≤ 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e165 x 108 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShielding\u003c\/th\u003e\n\u003ctd\u003eFull metal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSafety interlock\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eASTM D150; IEC 62631-2-1 (2018); IEC 62631-3-1 (2016)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0005783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser and the B1023000 adapter cable are not included.\u003c\/li\u003e\n  \u003cli\u003eThe analyser sets the usable band. The Bode 100 covers 1 Hz to 50 MHz, so with it the DSH 100 runs from 1 Hz to 5 MHz. Reaching 5 µHz needs an analyser such as OMICRON Lab's SPECTANO 100 (5 µHz to 5 kHz), discontinued on 31 December 2022.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab does not name the Bode 500 for the DSH 100, so ask us before planning a Bode 500 setup.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab designed the DSH 100 for solid materials.\u003c\/li\u003e\n  \u003cli\u003eReplace cables and electrodes after 500 mating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBode 100 Test Fixture Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDSH 100\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-wic-impedance-adapter-uk\"\u003eB-WIC\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDevice under test\u003c\/th\u003e\n\u003ctd\u003eSolid dielectric samples, 0.1 mm to 20 mm thick\u003c\/td\u003e\n\u003ctd\u003eWired (through-hole) components\u003c\/td\u003e\n\u003ctd\u003eSurface-mount components\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz (usable)\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz (usable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalysers named by OMICRON Lab\u003c\/th\u003e\n\u003ctd\u003eBode 100, impedance analysers, LCR meters\u003c\/td\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003ctd\u003eBode 100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-wic-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-smc-impedance-adapter-uk\"\u003e£650\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eDielectric response of polymers and thin films across frequency, with the supplied spacers for the air-reference measurement. Temperature-dependent measurement of insulation papers and glasses between -55 °C and +125 °C, with a heating pad and temperature sensor fitted, or with the holder in a climate chamber for sub-ambient tests.\u003c\/p\u003e\n\u003cp\u003eThe DSH 100 suits insulation and materials engineers who already have a Bode 100 or LCR meter.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x DSH 100 Dielectric Sample Holder\u003c\/li\u003e\n  \u003cli\u003e2 x PCB disk electrodes, one electrode with guard ring\u003c\/li\u003e\n  \u003cli\u003e2 x Tension control systems, with 50 N and 100 N spring\u003c\/li\u003e\n  \u003cli\u003e2 x Metal top plates, 10 mm and 5 mm thick\u003c\/li\u003e\n  \u003cli\u003e2 x Spacers, 0.3 mm thick\u003c\/li\u003e\n  \u003cli\u003e2 x Spacers, 0.8 mm thick\u003c\/li\u003e\n  \u003cli\u003e1 x Carrying case\u003c\/li\u003e\n  \u003cli\u003e1 x User manual, including safety instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab DSH 100 is \u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e ex VAT, and the Triaxial to BNC Adapter Cable is \u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e. Contact us for a formal quotation covering the holder, cable and a Bode 100.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the DSH 100 Work with the Bode 100?\u003c\/h3\u003e\n\u003cp\u003eYes. OMICRON Lab names the Bode 100 as a compatible analyser and supplies the B1023000 Triaxial to BNC Adapter Cable to connect it. With the Bode 100, the measurement range is 1 Hz to 5 MHz.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat Does the Analyser Source Need to Provide?\u003c\/h3\u003e\n\u003cp\u003eA galvanically isolated (floating) voltage, isolated from mains, at no more than 200 V peak and 50 mA peak. Connect the DSH 100 grounding terminal to laboratory earth before measuring.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (4 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/dielectric-sample-holder-dsh-100\"\u003eOMICRON Lab Dielectric Sample Holder DSH 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/dsh-100-dielectric-sample-holder\"\u003eOMICRON Lab Shop: DSH 100 Dielectric Sample Holder\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/spectano-100\"\u003eOMICRON Lab SPECTANO 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/bode-100\"\u003eOMICRON Lab Bode 100\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":54807673700727,"sku":"P0005783","price":5215.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0005783-dielectric-sample-holder-omicron-lab-dsh-100-precision-material-analysis-instrument-72445704044919.png?v=1733708086"},{"product_id":"omicron-lab-triaxial-to-bnc-adapter-cable","title":"Triaxial to BNC Adapter Cable - DSH 100 Connectivity Solution","description":"\u003cp\u003eThe OMICRON Lab Triaxial to BNC Adapter Cable (B1023000) is a 0.5 m RG400 coaxial cable with a Lemo 1S.650 (male) connector at one end and a BNC (male) connector at the other. It connects the DSH 100 Dielectric Sample Holder to a Bode 100 or any other LCR meter with BNC connections. Materials and insulation engineers use it to run dielectric measurements on solid samples with an analyser they already own.\u003c\/p\u003e\n\n\u003ch2\u003eLemo 1S.650 to BNC for the DSH 100\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"\/es\/products\/omicron-lab-dsh-100-dielectric-sample-holder\"\u003eDSH 100\u003c\/a\u003e uses a triaxial LEMO interface (female plug PSA.1S.650.CLL) rather than BNC. This cable takes that interface to a standard BNC plug, so the holder can be wired to a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e, an impedance analyser or an LCR meter with BNC connections. The cable is RG400 coaxial, 0.5 m long, which keeps the run between holder and instrument short.\u003c\/p\u003e\n\n\u003ch2\u003eConnecting the DSH 100 to a Bode 100 or LCR Meter\u003c\/h2\u003e\n\u003cp\u003eOn the DSH 100, MEAS goes to the measurement input of the analyser and IN goes to the analyser output. OMICRON Lab designed the holder for an isolated voltage source, so the analyser must provide a galvanically isolated (floating) signal, isolated from mains. Stay within the DSH 100 limits of 200 V peak and 50 mA peak, and connect the holder's grounding terminal to laboratory earth before measuring. The safety interlock on the DSH 100 stops a cable being connected while the holder is open, and stops the holder being opened while a cable is connected.\u003c\/p\u003e\n\n\u003ch2\u003eCable Wear and Replacement\u003c\/h2\u003e\n\u003cp\u003eThe DSH 100 manual says to replace the cable and electrodes after 500 mating cycles. Every mating cycle counts, including those made when the holder is opened to change a sample, because the interlock only opens with the cable removed. Labs running many samples should keep a spare cable with the holder.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eB1023000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCable type\u003c\/th\u003e\n\u003ctd\u003eCoaxial RG400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector, holder end\u003c\/th\u003e\n\u003ctd\u003eLemo 1S.650 (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnector, instrument end\u003c\/th\u003e\n\u003ctd\u003eBNC (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMates with\u003c\/th\u003e\n\u003ctd\u003eDSH 100 triaxial LEMO interface (female plug PSA.1S.650.CLL)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInstruments named by OMICRON Lab\u003c\/th\u003e\n\u003ctd\u003eBode 100; any LCR meter with BNC connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOMICRON Lab publishes no impedance, voltage or capacitance rating for the cable itself. Work within the DSH 100 limits of 200 V peak and 50 mA peak.\u003c\/li\u003e\n  \u003cli\u003eOMICRON Lab does not state how many cables a given analyser setup needs. Ask us before ordering if you are unsure.\u003c\/li\u003e\n  \u003cli\u003eThe Bode 500 is not named for this cable or for the DSH 100, and it uses N-type connectors where the Bode 100 uses BNC.\u003c\/li\u003e\n  \u003cli\u003eThe analyser source must be galvanically isolated. A mains-referenced source must not drive the DSH 100.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDSH 100 Measurement Setup Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTriaxial to BNC Adapter Cable\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-dsh-100-dielectric-sample-holder\"\u003eDSH 100\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRole\u003c\/th\u003e\n\u003ctd\u003eConnects DSH 100 to a BNC instrument\u003c\/td\u003e\n\u003ctd\u003eHolds the solid dielectric sample\u003c\/td\u003e\n\u003ctd\u003eAnalyser\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003eLemo 1S.650 (male) to BNC (male)\u003c\/td\u003e\n\u003ctd\u003eTriaxial LEMO (female plug PSA.1S.650.CLL)\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003e5 µHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-dsh-100-dielectric-sample-holder\"\u003e£5,215\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-bode-100-vector-network-analyser-uk\"\u003e£5,920\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eConnecting a DSH 100 to a Bode 100 to measure polymers, epoxy resins or insulation papers from 1 Hz to 5 MHz. Using an existing BNC-equipped LCR meter with the DSH 100 for dielectric checks on thin films and glasses. Keeping a spare cable with the holder against the 500 mating cycle replacement interval.\u003c\/p\u003e\n\u003cp\u003eThe cable suits engineers who own a DSH 100 and want to use it with a BNC instrument rather than a dedicated dielectric analyser.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003eOMICRON Lab publishes no box list for this cable. The delivery is the cable itself:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTriaxial to BNC adapter cable, RG400, 0.5 m, Lemo 1S.650 (male) to BNC (male)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Triaxial to BNC Adapter Cable is \u003cspan data-ds-price=\"omicron-lab-triaxial-to-bnc-adapter-cable\"\u003e£125\u003c\/span\u003e ex VAT. Check that your analyser's source is galvanically isolated, or contact us for a formal quotation covering the cable, the DSH 100 and a Bode 100.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Instruments Can I Use with This Cable?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab names the Bode 100 and any other LCR meter with a BNC connection. The analyser's signal source must provide a galvanically isolated voltage.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the Cable Included with the DSH 100?\u003c\/h3\u003e\n\u003cp\u003eNo. The DSH 100 scope of delivery does not list it. Order it separately if your analyser has BNC connections.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (3 manufacturer pages)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/us-shop.omicron-lab.com\/products\/adapter-cable-triaxial-to-bnc\"\u003eOMICRON Lab Shop: Adapter Cable, Triaxial to BNC\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/material-analysis\/dielectric-sample-holder-dsh-100\"\u003eOMICRON Lab Dielectric Sample Holder DSH 100\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/bode-100\"\u003eOMICRON Lab Bode 100\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":54807707320695,"sku":"B1023000","price":125.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-b1023000-omicron-lab-triaxial-to-bnc-adapter-cable-triaxial-to-bnc-cable-dsh-100-accessory-72445806707063.png?v=1733708083"},{"product_id":"omicron-lab-b-tca-test-card-adapter-p0009653","title":"OMICRON Lab B-TCA Test Card Adapter","description":"\u003cp\u003eThe OMICRON Lab B-TCA is a test card adapter for impedance and S-parameter measurement of SMD components from DC to 450 MHz with a Bode 100 or Bode 500 vector network analyser. The DUT is soldered to a colour-coded test card that plugs into a 100-pin, 0.8 mm pitch card-edge connector, and four measurement setups together cover impedances from milliohms to megohms. A dedicated Open, Short and Load calibrator ships for each setup, with 32 test cards and cables for both analysers.\u003c\/p\u003e\n\n\u003ch2\u003eFour Measurement Setups for SMD Impedance From DC to 450 MHz\u003c\/h2\u003e\n\u003cp\u003eEach setup has its own test card, calibrator and best-suited impedance range. One-Port (black cards) measures impedance or S11 reflection, best suited to 500 mΩ to 10 kΩ and takes DUTs up to 15 mm contact to contact. Shunt-Thru (blue) is rated best for low impedance, 1 mΩ to 100 Ω, and Series-Thru (red) best for high impedance, 1 kΩ to 1 MΩ. Shunt-Thru with Rs (green) adds two user-fitted series resistors and reaches 20 mΩ to 4,500 Ω with a 950 Ω Rs. The two-port setups also measure S21 transmission.\u003c\/p\u003e\n\n\u003ch2\u003eType N Ports and Card-Edge Test Card Connector\u003c\/h2\u003e\n\u003cp\u003eSOURCE and CH2 are Type N connectors, and cables for both the \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e and the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e are supplied. Insertion loss from SOURCE to CH2 is under 0.1 dB from DC to 50 MHz and under 0.5 dB from 50 MHz to 450 MHz, with typical return loss better than 20 dB across the full range.\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the B-TCA, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setups\u003c\/th\u003e\n\u003ctd\u003eOne-Port, Shunt-Thru, Series-Thru, Shunt-Thru with Rs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurements\u003c\/th\u003e\n\u003ctd\u003eImpedance, S11 reflection (One-Port), S21 transmission (two-port)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalyser connectors\u003c\/th\u003e\n\u003ctd\u003eSOURCE and CH2, Type N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card connector\u003c\/th\u003e\n\u003ctd\u003eCard-edge, 100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInsertion loss, SOURCE to CH2\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.1 dB (DC to 50 MHz), \u0026lt; 0.5 dB (50 MHz to 450 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eReturn loss, SOURCE to CH2 (typ.)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 35 dB (DC to 10 MHz), \u0026gt; 28 dB (10 MHz to 200 MHz), \u0026gt; 20 dB (200 MHz to 450 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCommon mode inductance (SOURCE and CH2)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 40 µH at 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. current\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. inductor stored energy\u003c\/th\u003e\n\u003ctd\u003e350 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator Load\u003c\/th\u003e\n\u003ctd\u003e50 Ω ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e100 x 70 x 33 mm (including connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e+5 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-35 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e20% to 80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eSELV device (IEC 60950), protection class III\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe analyser is not included. The B-TCA connects to a \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eFor SMD parts up to 9.5 mm long and 7.5 mm wide on a Bode 100 below 50 MHz, the \u003ca href=\"\/es\/products\/omicron-lab-b-smc-impedance-adapter-uk\"\u003eB-SMC\u003c\/a\u003e impedance test fixture (1 Hz to 50 MHz, 20 mΩ to 600 kΩ) is the alternative.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eB-TCA adapter\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru-with-rs\"\u003eShunt-Thru with Rs set\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance against frequency of SMD capacitors, inductors and resistors up to 450 MHz on a Bode 500. Low-impedance work down to 1 mΩ on Shunt-Thru cards and high-impedance work up to 1 MΩ on Series-Thru cards, from one adapter. S21 transmission through a two-port setup without changing fixture.\u003c\/p\u003e\n\u003cp\u003eThe B-TCA suits engineers with a Bode 100 or Bode 500 who want soldered, repeatable SMD connections instead of a hand-built fixture.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eB-TCA test card adapter\u003c\/li\u003e\n  \u003cli\u003e2 N-N cables, 30 cm (for the Bode 500)\u003c\/li\u003e\n  \u003cli\u003e2 N-BNC cables, 50 cm (for the Bode 100)\u003c\/li\u003e\n  \u003cli\u003e1 calibrator each for One-Port, Shunt-Thru, Series-Thru and Shunt-Thru with Rs\u003c\/li\u003e\n  \u003cli\u003e8 test cards each for One-Port, Shunt-Thru, Series-Thru and Shunt-Thru with Rs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab B-TCA is \u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e ex VAT. For the analyser or spare card sets, contact us for a formal quotation. See all \u003ca href=\"\/es\/collections\/vector-network-analyser-accessories\"\u003evector network analyser accessories\u003c\/a\u003e in our range.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Cables Connect the B-TCA to a Bode 100 or Bode 500?\u003c\/h3\u003e\n\u003cp\u003eBoth cable sets are supplied. Use the two 30 cm N-N cables with a Bode 500 and the two 50 cm N-BNC cables with a Bode 100, one for SOURCE to the analyser output and one for CH2.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eCan I Measure SMD Parts Under DC Bias?\u003c\/h3\u003e\n\u003cp\u003eYes, within limits. The B-TCA has no internal bias-T, and its ports behave as 50 Ω, so up to 3.3 V DC needs no extensive DC blocking. For higher voltages OMICRON Lab suggests an external bias-T, or the Shunt-Thru with Rs setup, which allows up to 60 V DC at the DUT with a 950 Ω Rs.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280501817719,"sku":"P0009653","price":950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-p0009653-b-tca-test-card-adapter-p0009653-smd-impedance-measurement-fixture-omicron-lab-1171519234.png?v=1749055749"},{"product_id":"test-card-set-shunt-thru","title":"OMICRON Lab Test Card Set - Shunt-Thru","description":"\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru (P0011462) is a replacement set of 32 Shunt-Thru test cards and one Shunt-Thru calibrator for the B-TCA test card adapter. OMICRON Lab rates Shunt-Thru as the best of the four B-TCA setups for low impedance, with an optimal DUT impedance magnitude of 1 mΩ to 100 Ω, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. Order it to restock the blue Shunt-Thru cards when you characterise low-impedance passive SMD components.\u003c\/p\u003e\n\n\u003ch2\u003eShunt-Thru Impedance Measurement From 1 mΩ to 100 Ω\u003c\/h2\u003e\n\u003cp\u003eOn a Shunt-Thru test card the DUT is soldered between the signal pad and the GND pad, so it shunts the signal line to ground. This two-port arrangement gives the best low-impedance sensitivity of the four setups. Above 100 Ω the 50 Ω parallel path degrades sensitivity, so for high-impedance parts move to the Series-Thru set. The maximum recommended DUT size is about 9 mm from one contact to the other, with a maximum width of 10 mm.\u003c\/p\u003e\n\n\u003ch2\u003eShunt-Thru Calibrator: Open, Short and Load\u003c\/h2\u003e\n\u003cp\u003eThe blue Shunt-Thru calibrator carries Open (Thru), Short and Load references, with the Load at 50 Ω ±0.1%. In the Bode Analyzer Suite, run Open first, then Short with the Short-Delay Time set to 23 ps, then Load. A Thru-only calibration using the Open element is possible, but OMICRON Lab notes that it does not remove impedance mismatch or the low-frequency ground-loop error, so a full Open, Short and Load calibration is the one to use for low-impedance work.\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setup\u003c\/th\u003e\n\u003ctd\u003eShunt-Thru (two-port impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT connection\u003c\/th\u003e\n\u003ctd\u003eBetween signal and GND pads\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003e1 mΩ to 100 Ω (impedance magnitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, max. width 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator references\u003c\/th\u003e\n\u003ctd\u003eOpen (Thru), Short, Load (50 Ω ±0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz (B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard-edge connector\u003c\/th\u003e\n\u003ctd\u003e100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage and current (B-TCA)\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eB-TCA test card adapter (P0009653)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500 (via the B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThese are replacement parts for the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e. The adapter and the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e analyser are not included.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eSensitivity degrades above 100 Ω. For 1 kΩ to 1 MΩ choose the \u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e; to push a shunt measurement up to 4,500 Ω, use the \u003ca href=\"\/es\/products\/test-card-set-shunt-thru-with-rs\"\u003eShunt-Thru with Rs set\u003c\/a\u003e with a 950 Ω Rs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA adapter\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eShunt-Thru set\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru-with-rs\"\u003eShunt-Thru with Rs set\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance against frequency, up to 450 MHz, of SMD parts whose impedance magnitude sits between 1 mΩ and 100 Ω. Low-impedance measurements where the One-Port setup's 500 mΩ lower limit is too high.\u003c\/p\u003e\n\u003cp\u003eThis set suits engineers who already run a B-TCA and have used up the eight Shunt-Thru cards supplied with it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e32 Shunt-Thru test cards (4 × 8)\u003c\/li\u003e\n  \u003cli\u003e1 Shunt-Thru calibrator\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru is \u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e ex VAT. If you do not have the adapter yet, the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA\u003c\/a\u003e ships with eight cards and a calibrator per setup; contact us for a formal quotation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhy Choose Shunt-Thru Over One-Port for Low Impedance?\u003c\/h3\u003e\n\u003cp\u003eBecause its best-suited range starts at 1 mΩ, against 500 mΩ for One-Port. OMICRON Lab rates Shunt-Thru best and One-Port only OK for low impedance, as the One-Port range is limited by contact resistance and the analyser's signal-to-noise ratio.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eIs This the Same as the Shunt-Thru with Rs Set?\u003c\/h3\u003e\n\u003cp\u003eNo. Shunt-Thru with Rs cards are green and carry extra solder locations for two series resistors (Rs, 0603 to 1206), which move the measurement range upwards. With Rs at 0 Ω that setup behaves like Shunt-Thru, but the blue Shunt-Thru cards here need no resistors.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280504078711,"sku":"P0011462","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-test-card-set-shunt-thru-card-set.png?v=1795011456"},{"product_id":"test-card-set-series-thru","title":"OMICRON Lab Test Card Set - Series-Thru","description":"\u003cp\u003eThe OMICRON Lab Test Card Set - Series-Thru (P0011464) is a replacement set of 32 Series-Thru test cards and one Series-Thru calibrator for the B-TCA test card adapter. OMICRON Lab rates Series-Thru as the best of the four B-TCA setups for high impedance, with an optimal DUT impedance magnitude of 1 kΩ to 1 MΩ, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. Order it to restock the red Series-Thru cards when you characterise high-impedance passive SMD components.\u003c\/p\u003e\n\n\u003ch2\u003eSeries-Thru Impedance Measurement From 1 kΩ to 1 MΩ\u003c\/h2\u003e\n\u003cp\u003eOn a Series-Thru test card the DUT is soldered between the two pads in the signal line, the signal pad and the CH2 pad, so the test signal passes through it. This two-port arrangement gives the best high-impedance sensitivity of the four setups. Below 1 kΩ the 50 Ω termination and source impedance degrade sensitivity, so for low-impedance parts move to the Shunt-Thru set. The maximum recommended DUT size is about 9 mm from one contact to the other.\u003c\/p\u003e\n\n\u003ch2\u003eSeries-Thru Calibrator: Open, Short and Load\u003c\/h2\u003e\n\u003cp\u003eThe red Series-Thru calibrator carries Open, Short and Load references, with the Short doubling as the Thru and the Load at 50 Ω ±0.1%. In the Bode Analyzer Suite, run Open first, then Short with the Short-Delay Time set to 0 ps, then Load. A Thru-only calibration using the Short element is possible, but OMICRON Lab notes that it does not remove impedance mismatch errors, so a full Open, Short and Load calibration is the one to use for high-impedance work.\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setup\u003c\/th\u003e\n\u003ctd\u003eSeries-Thru (two-port impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT connection\u003c\/th\u003e\n\u003ctd\u003eBetween signal and CH2 pads in the signal line\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ (impedance magnitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator references\u003c\/th\u003e\n\u003ctd\u003eOpen, Short (Thru), Load (50 Ω ±0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz (B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard-edge connector\u003c\/th\u003e\n\u003ctd\u003e100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage and current (B-TCA)\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eB-TCA test card adapter (P0009653)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500 (via the B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThese are replacement parts for the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e. The adapter and the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e analyser are not included.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eSensitivity degrades below 1 kΩ. For 1 mΩ to 100 Ω choose the \u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e; for 500 mΩ to 10 kΩ on a single port, the \u003ca href=\"\/es\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA adapter\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eSeries-Thru set\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru-with-rs\"\u003eShunt-Thru with Rs set\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance against frequency, up to 450 MHz, of SMD parts whose impedance magnitude sits between 1 kΩ and 1 MΩ. High-impedance measurements beyond the 10 kΩ upper limit of the One-Port setup.\u003c\/p\u003e\n\u003cp\u003eThis set suits engineers who already run a B-TCA and have used up the eight Series-Thru cards supplied with it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e32 Series-Thru test cards (4 × 8)\u003c\/li\u003e\n  \u003cli\u003e1 Series-Thru calibrator\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Test Card Set - Series-Thru is \u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e ex VAT. If you do not have the adapter yet, the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA\u003c\/a\u003e ships with eight cards and a calibrator per setup; contact us for a formal quotation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Setup Should I Use Below 1 kΩ?\u003c\/h3\u003e\n\u003cp\u003eShunt-Thru for 1 mΩ to 100 Ω, or One-Port for 500 mΩ to 10 kΩ. OMICRON Lab rates Series-Thru worst of the four setups for low impedance, because the 50 Ω termination and source impedance limit its sensitivity there.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eCan I Calibrate the Series-Thru Setup With a Thru Only?\u003c\/h3\u003e\n\u003cp\u003eYes, using the Short element of the calibrator as the Thru. OMICRON Lab prefers a full Open, Short and Load calibration, because a Thru-only calibration does not remove impedance mismatch errors.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280504471927,"sku":"P0011464","price":165.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-test-card-set-series-thru-card-set.png?v=1795011456"},{"product_id":"test-card-set-one-port","title":"OMICRON Lab Test Card Set - One-Port","description":"\u003cp\u003eThe OMICRON Lab Test Card Set - One-Port (P0011465) is a replacement set of 32 One-Port test cards and one One-Port calibrator for the B-TCA test card adapter. The One-Port setup measures impedance or S11 reflection on a single port, with an optimal DUT impedance magnitude of 500 mΩ to 10 kΩ, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. It takes the largest parts of the four B-TCA setups, up to 15 mm from one contact to the other.\u003c\/p\u003e\n\n\u003ch2\u003eOne-Port Impedance and S11 From 500 mΩ to 10 kΩ\u003c\/h2\u003e\n\u003cp\u003eOn a One-Port test card the DUT is soldered between the signal pad and the GND pad, and the analyser measures the reflection from it. OMICRON Lab rates One-Port as OK for both low and high impedance: it sits between the Shunt-Thru and Series-Thru setups rather than leading at either end. Its range is limited by contact resistance and by the signal-to-noise ratio of the analyser.\u003c\/p\u003e\n\n\u003ch2\u003eOne-Port Calibrator: Open, Short and Load\u003c\/h2\u003e\n\u003cp\u003eThe black One-Port calibrator carries Open, Short and Load references, with the Load at 50 Ω. In the Bode Analyzer Suite, select User-Range or Full-Range Impedance, run Open first, then Short with the Short-Delay Time set to 0 ps, then Load. When the calibration window closes, the calibration icon turns green to show the calibration is active.\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setup\u003c\/th\u003e\n\u003ctd\u003eOne-Port (impedance or S11 reflection)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT connection\u003c\/th\u003e\n\u003ctd\u003eBetween signal and GND pads\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ (impedance magnitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator references\u003c\/th\u003e\n\u003ctd\u003eOpen, Short, Load (50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz (B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard-edge connector\u003c\/th\u003e\n\u003ctd\u003e100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage and current (B-TCA)\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eB-TCA test card adapter (P0009653)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500 (via the B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThese are replacement parts for the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e. The adapter and the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e analyser are not included.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eOne-Port is not the best choice at either end of the range. Below 500 mΩ choose the \u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e (1 mΩ to 100 Ω); above 10 kΩ choose the \u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e (1 kΩ to 1 MΩ).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA adapter\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eOne-Port set\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru-with-rs\"\u003eShunt-Thru with Rs set\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance or S11 reflection against frequency, up to 450 MHz, of SMD parts whose impedance magnitude sits between 500 mΩ and 10 kΩ. Measurements on larger SMD parts, up to 15 mm contact to contact, that will not fit the 9 mm limit of the two-port cards.\u003c\/p\u003e\n\u003cp\u003eThis set suits engineers who already run a B-TCA and have used up the eight One-Port cards supplied with it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e32 One-Port test cards (4 × 8)\u003c\/li\u003e\n  \u003cli\u003e1 One-Port calibrator\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Test Card Set - One-Port is \u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e ex VAT. If you do not have the adapter yet, the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA\u003c\/a\u003e ships with eight cards and a calibrator per setup; contact us for a formal quotation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat Is the Largest Component the One-Port Card Takes?\u003c\/h3\u003e\n\u003cp\u003eOMICRON Lab recommends a maximum DUT size of 15 mm from one contact to the other. The Series-Thru and Shunt-Thru cards are limited to about 9 mm, so One-Port is the setup for longer SMD parts.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhen Should I Use a Two-Port Setup Instead?\u003c\/h3\u003e\n\u003cp\u003eWhen the DUT impedance is below 500 mΩ or above 10 kΩ. Shunt-Thru is rated best for low impedance (1 mΩ to 100 Ω) and Series-Thru best for high impedance (1 kΩ to 1 MΩ); One-Port is rated OK at both ends.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280504602999,"sku":"P0011465","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-test-card-set-one-port-card-set.png?v=1795011457"},{"product_id":"test-card-set-shunt-thru-with-rs","title":"OMICRON Lab Test Card Set - Shunt-Thru with Rs","description":"\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru with Rs (P0011466) is a replacement set of 32 test cards and one calibrator for the Shunt-Thru with Rs setup of the B-TCA test card adapter. Two series resistors (Rs) fitted by the user set the measurement range: from 1 mΩ to 100 Ω with Rs at 0 Ω up to 20 mΩ to 4,500 Ω with Rs at 950 Ω, within the B-TCA's recommended DC to 450 MHz range, on a Bode 500 (10 mHz to 450 MHz) or Bode 100 (1 Hz to 50 MHz) vector network analyser. Higher Rs values also raise the permitted DC voltage at the DUT, from 3.3 V at 0 Ω to the 60 V safety limit at 950 Ω.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing Rs: Shunt-Thru Impedance Range and DC Voltage\u003c\/h2\u003e\n\u003cp\u003eWith Rs at 0 Ω the setup behaves like plain Shunt-Thru; larger Rs values extend it towards higher impedance. The B-TCA user manual gives these optimal ranges and limits:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eRs\u003c\/th\u003e\n\u003cth\u003eOptimal impedance range\u003c\/th\u003e\n\u003cth\u003eMax. DC voltage at DUT\u003c\/th\u003e\n\u003cth\u003eMax. power in Rs\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e0 Ω\u003c\/th\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e3.3 V\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e200 Ω\u003c\/th\u003e\n\u003ctd\u003e5 mΩ to 1,125 Ω\u003c\/td\u003e\n\u003ctd\u003e16.5 V\u003c\/td\u003e\n\u003ctd\u003e0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e450 Ω\u003c\/th\u003e\n\u003ctd\u003e10 mΩ to 2,250 Ω\u003c\/td\u003e\n\u003ctd\u003e33 V\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e499 Ω\u003c\/th\u003e\n\u003ctd\u003e11 mΩ to 2,480 Ω\u003c\/td\u003e\n\u003ctd\u003e36 V\u003c\/td\u003e\n\u003ctd\u003e2.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003e950 Ω\u003c\/th\u003e\n\u003ctd\u003e20 mΩ to 4,500 Ω\u003c\/td\u003e\n\u003ctd\u003e60 V (safety limit)\u003c\/td\u003e\n\u003ctd\u003e≈ 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePower in Rs follows P = (V \/ (Rs + 50 Ω))² × Rs, where V is the voltage at the DUT connection point.\u003c\/p\u003e\n\n\u003ch2\u003eFitting Rs and Calibrating the Green Calibrator\u003c\/h2\u003e\n\u003cp\u003eOn each green test card, solder the DUT between the signal pad and the GND pad, then solder two Rs resistors (0603 to 1206) at the marked locations to close the measurement path. The maximum recommended DUT size is about 9 mm x 9 mm. Enter the Rs value in the Impedance\/Reflection Measurement Setup or the Calibration dialog of the Bode Analyzer Suite, then run Open, Short with the Short-Delay Time set to 23 ps, and Load (50 Ω ±0.1%).\u003c\/p\u003e\n\n\u003ch2\u003eSoldering and Fitting B-TCA Test Cards\u003c\/h2\u003e\n\u003cp\u003eEach test card is a 1.57 mm (nominal) PCB for the 100-pin, 0.8 mm pitch card-edge connector of the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e, with the DUT soldered directly to the marked pads. Signal line contact resistance is 2 mΩ typ. with under 1 mΩ repeatability, and the connection is rated for 1,000 mating cycles. Wear gloves when breaking cards off and remove any sharp edges. Clean the contacts, then push the card straight down at its centre with under 2° of tilt.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMeasurement setup\u003c\/th\u003e\n\u003ctd\u003eShunt-Thru with Rs (two-port impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDUT connection\u003c\/th\u003e\n\u003ctd\u003eBetween signal and GND pads, plus 2 Rs solder locations\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRs package sizes\u003c\/th\u003e\n\u003ctd\u003e0603 to 1206\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eDepends on Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCalibrator references\u003c\/th\u003e\n\u003ctd\u003eOpen, Short, Load (50 Ω ±0.1%), 6 Rs locations\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRecommended frequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 450 MHz (B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard thickness\u003c\/th\u003e\n\u003ctd\u003e1.57 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCard-edge connector\u003c\/th\u003e\n\u003ctd\u003e100 pins, 0.8 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSignal line contact resistance (4 pins)\u003c\/th\u003e\n\u003ctd\u003e2 mΩ typ., \u0026lt; 1 mΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card ground contact resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.5 mΩ typ., \u0026lt; 100 µΩ repeatability typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card mating cycles\u003c\/th\u003e\n\u003ctd\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. voltage and current (B-TCA)\u003c\/th\u003e\n\u003ctd\u003e60 V DC, 30 V AC, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eB-TCA test card adapter (P0009653)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompatible analysers\u003c\/th\u003e\n\u003ctd\u003eBode 100, Bode 500 (via the B-TCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThese are replacement parts for the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA test card adapter\u003c\/a\u003e. The adapter and the \u003ca href=\"\/es\/products\/omicron-lab-bode-100-vector-network-analyser-uk\"\u003eBode 100\u003c\/a\u003e or \u003ca href=\"\/es\/products\/omicron-lab-bode-500-vector-network-analyser-vna\"\u003eBode 500\u003c\/a\u003e analyser are not included.\u003c\/li\u003e\n  \u003cli\u003eB-TCA limits are 60 V DC or 30 V AC, 1 A, and under 350 mJ stored in an inductive DUT. Use only DC sources isolated from mains.\u003c\/li\u003e\n  \u003cli\u003eThe B-TCA has no internal bias-T. Above 3.3 V DC, OMICRON Lab suggests an external bias-T between the analyser and the adapter.\u003c\/li\u003e\n  \u003cli\u003eRs resistors are not on the OMICRON Lab delivery list for this set. For 1 kΩ to 1 MΩ without resistors, choose the \u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eB-TCA Test Card Set Comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA adapter\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-shunt-thru\"\u003eShunt-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-series-thru\"\u003eSeries-Thru set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/es\/products\/test-card-set-one-port\"\u003eOne-Port set\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eShunt-Thru with Rs set\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOrder number\u003c\/th\u003e\n\u003ctd\u003eP0009653\u003c\/td\u003e\n\u003ctd\u003eP0011462\u003c\/td\u003e\n\u003ctd\u003eP0011464\u003c\/td\u003e\n\u003ctd\u003eP0011465\u003c\/td\u003e\n\u003ctd\u003eP0011466\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003ctd\u003eAdapter, 2 N-N and 2 N-BNC cables, 4 calibrators, 32 test cards (8 per setup)\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003ctd\u003e32 test cards, 1 calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTest card colour\u003c\/th\u003e\n\u003ctd\u003eAll four\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eBest-suited impedance range\u003c\/th\u003e\n\u003ctd\u003eMilliohms to megohms across four setups\u003c\/td\u003e\n\u003ctd\u003e1 mΩ to 100 Ω\u003c\/td\u003e\n\u003ctd\u003e1 kΩ to 1 MΩ\u003c\/td\u003e\n\u003ctd\u003e500 mΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003eSet by Rs: 1 mΩ to 100 Ω (0 Ω) up to 20 mΩ to 4,500 Ω (950 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMax. recommended DUT size\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact, 10 mm wide\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e15 mm contact to contact\u003c\/td\u003e\n\u003ctd\u003e≈ 9 mm x 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eShort-Delay Time\u003c\/th\u003e\n\u003ctd\u003ePer setup\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e0 ps\u003c\/td\u003e\n\u003ctd\u003e23 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"omicron-lab-b-tca-test-card-adapter-p0009653\"\u003e£950\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-series-thru\"\u003e£165.02\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-one-port\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eImpedance against frequency, up to 450 MHz, of SMD parts between 20 mΩ and 4,500 Ω with a 950 Ω Rs, beyond the 100 Ω ceiling of plain Shunt-Thru. Measurements with a DC voltage at the DUT above 3.3 V and up to 60 V, set by the Rs value.\u003c\/p\u003e\n\u003cp\u003eThis set suits engineers who already run a B-TCA and have used up the eight Shunt-Thru with Rs cards supplied with it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e32 Shunt-Thru with Rs test cards (4 × 8)\u003c\/li\u003e\n  \u003cli\u003e1 Shunt-Thru with Rs calibrator\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe OMICRON Lab Test Card Set - Shunt-Thru with Rs is \u003cspan data-ds-price=\"test-card-set-shunt-thru-with-rs\"\u003e£175\u003c\/span\u003e ex VAT. If you do not have the adapter yet, the \u003ca href=\"\/es\/products\/omicron-lab-b-tca-test-card-adapter-p0009653\"\u003eB-TCA\u003c\/a\u003e ships with eight cards and a calibrator per setup; contact us for a formal quotation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich Rs Value Should I Fit?\u003c\/h3\u003e\n\u003cp\u003ePick the Rs whose optimal range covers your DUT and whose DC voltage limit covers your bias. For example, 200 Ω gives 5 mΩ to 1,125 Ω with up to 16.5 V DC at the DUT, and 950 Ω gives 20 mΩ to 4,500 Ω up to the 60 V safety limit. Use the same Rs value on the calibrator and the test cards.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eAre the Rs Resistors Included?\u003c\/h3\u003e\n\u003cp\u003eNo. OMICRON Lab lists 32 test cards and one calibrator for this set. You fit two Rs resistors (0603 to 1206) to each test card and six to the calibrator.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 18 November 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (1 manufacturer page, 1 user manual)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.omicron-lab.com\/products\/vector-network-analysis\/accessories\/b-tca-test-card-adapter\"\u003eOMICRON Lab B-TCA Test Card Adapter\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/omicron-lab\/p0009653\/omicron-lab-b-tca-test-card-adapter-user-manual.pdf\"\u003eB-TCA User Manual (ENU 1302 05 02)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"OMICRON-Lab","offers":[{"title":"Default Title","offer_id":55280504996215,"sku":"P0011466","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/files\/omicron-lab-test-card-set-shunt-thru-with-rs-card-set.png?v=1795011457"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/logo-omicron-lab-250.jpg?v=1724338227","url":"https:\/\/thedebugstore.com\/es\/collections\/omicron-lab-catalogue-uk.oembed","provider":"Debug Store","version":"1.0","type":"link"}