{"title":"LCD Click Boards™","description":"\u003cp data-mce-fragment=\"1\"\u003eLCD Click Boards™ from MikroE are specifically designed to provide an easy and convenient way to add LCD display functionality to your projects. These Click Boards™ typically feature an LCD module, such as an alphanumeric or graphical display, along with the necessary control circuitry. They often support various display sizes, resolutions, and color options.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTo use an LCD Click Board™, you would typically connect it to your microcontroller board using the provided interface connectors. MikroE Click Boards™ follow a standardized interface, making them compatible with a wide range of development platforms. Once connected, you can utilize the MikroE software libraries or develop your own code to control and display information on the LCD.\u003c\/p\u003e","products":[{"product_id":"lcd-mono-click-board-mikroe-3789-uk","title":"LCD Mono Click Board™","description":"\u003ch3\u003eHow Does The LCD Mono Click Board™ Work?\u003c\/h3\u003e\n\n\u003cp\u003eThe LS013B7DH03 LCD display from Sharp has a reflective active-matrix with slightly transmissive type memory liquid crystal display module with 128 x128 panel which uses CG silicon thin film transistor. Its transmissive mode is available by implementation with backlight and you can control the display with serial data signal communication. It features a thin, light and compact module with monolithic technology and its most important feature is the super low power consumption TFT panel. For an MCU application, a powerful display can often be off-limits, either because of price, CPU processing power or power budget. However, if you use the EFM32's energy saving capabilities together with a Sharp low-power matrix memory LCD you can create a powerful display application. The application is capable of driving a 128x128 pixel display drawing as little as 2 µA while showing a static image. Even when updating the frame every second the current consumption can be lower than 5 µA.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Shop Click Boards Display \u0026amp; LED LCD Mono Click inner\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/www.mikroe.com\/img\/images\/lcd-mono-click-inner-img.jpg\" src=\"https:\/\/www.mikroe.com\/img\/images\/lcd-mono-click-inner-img.jpg\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe display used for the \u003cem\u003e\u003cstrong\u003eLCD Mono Click Board™\u003c\/strong\u003e\u003c\/em\u003e, the LS013B7DH03 LCD, is a 1.28\", 128x128 pixels monochrome display, with a 3-wire SPI interface. Apart from the SPI interface, the display requires a 3.3V power supply, and 3 extra pins named EXTMODE, EXTCOMIN and DISP. The SPI protocol consists of three modes. At the start of each SPI transfer, a mode command (1 byte) is sent first. The modes are:\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003eUpdate Image\u003c\/li\u003e\n    \u003cli\u003eToggle Polarity Inversion\u003c\/li\u003e\n    \u003cli\u003eClear Display\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe EXTMODE pin controls how polarity inversion is controlled. The display requires that the polarity across the Liquid Crystal Cell is reversed at a constant frequency. This polarity inversion prevents charge building up within the cell. If EXTMODE is LOW the polarity inversion is toggled by sending a special command over SPI. If it is HIGH polarity inversion is controlled by the EXTCOMIN pin. If EXTMODE is HIGH the polarity inversion is armed for every rising edge of the EXTCOMIN pin. The actual polarity inversion is triggered at the next transision of SCS. The toggling frequency should be at least 1 Hz. If EXTMODE is LOW this pin is ignored. The DISP pin toggles the display on or off (without the pixels losing their state). When LOW the display is off, when HIGH the display is on.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eLCD Mono Click Board™\u003c\/strong\u003e is designed to be operated only with 3.3V logic level. A proper logic voltage level conversion should be performed before the \u003cstrong\u003eLCD Mono Click Board™\u003c\/strong\u003e is used with MCUs with logic levels of 5V.\u003c\/p\u003e\n\n\u003ch3\u003eSPECIFICATIONS\u003c\/h3\u003e\n\n\u003csection\u003e\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eType\u003c\/td\u003e\n            \u003ctd\u003eLCD\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eApplications\u003c\/td\u003e\n            \u003ctd\u003e128x128 pixels monochrome display, with a 3-wire SPI interface\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOn-board modules\u003c\/td\u003e\n            \u003ctd\u003eLS013B7DH03 LCD display from Sharp\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eKey Features\u003c\/td\u003e\n            \u003ctd\u003eEFM32 helps reduce power consumption, driving a 128x128 pixel display drawing as little as 2 µA while showing a static image\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface\u003c\/td\u003e\n            \u003ctd\u003eGPIO,SPI\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCompatibility\u003c\/td\u003e\n            \u003ctd\u003emikroBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eClick board size\u003c\/td\u003e\n            \u003ctd\u003eL (57.15 x 25.4 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003ch3\u003ePINOUT DIAGRAM\u003c\/h3\u003e\n\n\u003cp\u003eThis table shows how the pinout on the \u003cstrong\u003eLCD Mono Click Board™\u003c\/strong\u003e corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).\u003c\/p\u003e\n\n\u003ctable width=\"549\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth colspan=\"4\"\u003e\u003cimg alt=\"Mikrobus logo.png\" data-entity-type=\"\" data-entity-uuid=\"\" data-mce-src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\" src=\"https:\/\/cdn.mikroe.com\/img\/mikrobus\/mikroBUS-logo-black.png\"\u003e\u003c\/th\u003e\n            \u003cth\u003ePin\u003c\/th\u003e\n            \u003cth\u003eNotes\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003eAN\u003c\/td\u003e\n            \u003ctd\u003ePWM\u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCOM Inversion polarity OUT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003eRST\u003c\/td\u003e\n            \u003ctd\u003eINT\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eChip Enable\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eCS\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003eCS\u003c\/td\u003e\n            \u003ctd\u003eRX\u003c\/td\u003e\n            \u003ctd\u003e14\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Clock\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSCK\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003eSCK\u003c\/td\u003e\n            \u003ctd\u003eTX\u003c\/td\u003e\n            \u003ctd\u003e13\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data Out\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDO\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003eMISO\u003c\/td\u003e\n            \u003ctd\u003eSCL\u003c\/td\u003e\n            \u003ctd\u003e12\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSPI Data IN\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eSDI\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003eMOSI\u003c\/td\u003e\n            \u003ctd\u003eSDA\u003c\/td\u003e\n            \u003ctd\u003e11\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Supply\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e3.3V\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e3.3V\u003c\/td\u003e\n            \u003ctd\u003e5V\u003c\/td\u003e\n            \u003ctd\u003e10\u003c\/td\u003e\n            \u003ctd\u003eNC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003eGND\u003c\/td\u003e\n            \u003ctd\u003e9\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGround\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eONBOARD SETTINGS AND INDICATORS\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003cth\u003eLabel\u003c\/th\u003e\n            \u003cth\u003eName\u003c\/th\u003e\n            \u003cth\u003eDefault\u003c\/th\u003e\n            \u003cth\u003e Description\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLD1\u003c\/td\u003e\n            \u003ctd\u003ePWR\u003c\/td\u003e\n            \u003ctd\u003e-\u003c\/td\u003e\n            \u003ctd\u003ePower LED indicator\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eJP1\u003c\/td\u003e\n            \u003ctd\u003eMODE SEL\u003c\/td\u003e\n            \u003ctd\u003eLeft\u003c\/td\u003e\n            \u003ctd\u003eCOM Inversion mode Selection jumper:\u003cbr\u003e\n            left position 0, right position 1\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e \u003c\/h3\u003e","brand":"Mikroelektronika d.o.o.","offers":[{"title":"Default Title","offer_id":37768431501501,"sku":"MIKROE-3789","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/products\/mikroelektronika-d-o-o-click-board-lcd-mono-click-board-30245292671165.jpg?v=1685195398"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0522\/6931\/8333\/collections\/lg-lcd-mono-click-3789-breadboard.jpg?v=1724338068","url":"https:\/\/thedebugstore.com\/es\/collections\/lcd-click-boards-catalogue.oembed","provider":"Debug Store","version":"1.0","type":"link"}