{"product_id":"aaronia-powerlog-50700-205-007","title":"Aaronia PowerLOG 50700","description":"\u003cp\u003eThe Aaronia PowerLOG 50700 is a passive double-ridged horn antenna covering 5 GHz to 70 GHz. It has a 1.85 mm V (f) connector, measures 50 x 32 x 34 mm and weighs 50 g, and is suitable for both transmitting and receiving, and for EMC emissions work.\u003c\/p\u003e\n\n\u003ch2\u003e5 GHz to 70 GHz in a 50 g Horn\u003c\/h2\u003e\n\u003cp\u003eThe PowerLOG 50700 covers 5 GHz to 70 GHz in a horn measuring 50 x 32 x 34 mm and weighing 50 g, with a 1.85 mm V (f) connector to carry the full range. It mounts on the supplied aluminium bracket. Aaronia states that the gain of its standard PowerLOG horns rises with frequency to a maximum of about 25 dBi, which offsets the rising cable loss at higher frequencies. The technical datasheet gives return loss, VSWR, gain and antenna factor as plots, and the -3 dB beamwidth as a table.\u003c\/p\u003e\n\n\u003ch2\u003eCompact Microwave Horn\u003c\/h2\u003e\n\u003cp\u003eAt 50 x 32 x 34 mm and 50 g, the PowerLOG 50700 is small enough to sit close to a device under test. \u003c\/p\u003e\n\n\u003ch2\u003eCalibration Data Included\u003c\/h2\u003e\n\u003cp\u003eAaronia states each PowerLOG is delivered with high-resolution calibration data (certificate and download link to an Excel file). With the antenna factor applied, the spectrum analyser reading converts to field strength, and in transmit use the gain figures let you work out the field strength produced at the test distance.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003e5 GHz to 70 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eDouble-ridged horn (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNominal impedance\u003c\/th\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRF connector\u003c\/th\u003e\n\u003ctd\u003e1.85 mm V (f)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e50 x 32 x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 92% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAaronia part number\u003c\/th\u003e\n\u003ctd\u003e205\/007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAaronia's datasheet gives no maximum input power for the 50700, and states its gain only as a maximum of 25 dBi. Ask us before using it to transmit at high power.\u003c\/li\u003e\n  \u003cli\u003eA horn is directional: it must be aimed at the device under test, and its coverage at short distances is limited by the beamwidth.\u003c\/li\u003e\n  \u003cli\u003eTransmit use is subject to local radio regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePowerLOG Range Compared\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eGain\u003c\/th\u003e\n\u003cth\u003eMax. input\u003c\/th\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePowerLOG 10800\u003c\/td\u003e\n\u003ctd\u003e1 GHz to 8 GHz\u003c\/td\u003e\n\u003ctd\u003e4 to 13 dBi\u003c\/td\u003e\n\u003ctd\u003e400 W (peak), 200 W (CW)\u003c\/td\u003e\n\u003ctd\u003eN (female)\u003c\/td\u003e\n\u003ctd\u003e1400 g\u003c\/td\u003e\n\u003ctd\u003e205\/001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePowerLOG 70180\u003c\/td\u003e\n\u003ctd\u003e700 MHz to 18 GHz\u003c\/td\u003e\n\u003ctd\u003e2 to 17 dBi\u003c\/td\u003e\n\u003ctd\u003e500 W (peak), 300 W (CW)\u003c\/td\u003e\n\u003ctd\u003eN (female)\u003c\/td\u003e\n\u003ctd\u003e1400 g\u003c\/td\u003e\n\u003ctd\u003e205\/002\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePowerLOG 40400\u003c\/td\u003e\n\u003ctd\u003e4 GHz to 40 GHz\u003c\/td\u003e\n\u003ctd\u003e12 to 17 dBi\u003c\/td\u003e\n\u003ctd\u003e300 W (peak), 150 W (CW)\u003c\/td\u003e\n\u003ctd\u003e2.92 mm K (f)\u003c\/td\u003e\n\u003ctd\u003e150 g\u003c\/td\u003e\n\u003ctd\u003e205\/003\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePowerLOG 50700 (this page)\u003c\/td\u003e\n\u003ctd\u003e5 GHz to 70 GHz\u003c\/td\u003e\n\u003ctd\u003e25 dBi (max.)\u003c\/td\u003e\n\u003ctd\u003enot stated\u003c\/td\u003e\n\u003ctd\u003e1.85 mm V (f)\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003ctd\u003e205\/007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eEMC and interference emission measurements, and receive measurements on microwave and millimetre-wave devices with a spectrum analyser or oscilloscope, where a small horn can sit close to the device.\u003c\/p\u003e\n\u003cp\u003eThe PowerLOG 50700 suits EMC test engineers and RF and microwave engineers who need a calibrated horn for 5 GHz to 70 GHz.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePowerLOG 50700 antenna\u003c\/li\u003e\n  \u003cli\u003eAluminium mounting bracket and screws\u003c\/li\u003e\n  \u003cli\u003eCalibration data\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eRequest a formal quotation for the PowerLOG 50700, or contact us to check it against your amplifier, analyser and test distance before you order.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich PowerLOG Model Do I Need?\u003c\/h3\u003e\n\u003cp\u003eChoose by frequency range. The 10800 covers 1 GHz to 8 GHz, the 70180 700 MHz to 18 GHz, the 40400 4 GHz to 40 GHz and the 50700 5 GHz to 70 GHz. The 70180 has the highest published power rating (500 W peak), followed by the 10800 (400 W peak); Aaronia gives no rating for the 50700.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eCan the PowerLOG 50700 Transmit and Receive?\u003c\/h3\u003e\n\u003cp\u003eYes. Aaronia states the PowerLOG series is suitable for both transmitting and receiving, within local radio regulations.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eIs Calibration Data Supplied With the PowerLOG 50700?\u003c\/h3\u003e\n\u003cp\u003eAaronia states each PowerLOG is delivered with high-resolution calibration data (certificate and download link to an Excel file).\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich Cable Do I Need for the PowerLOG 50700?\u003c\/h3\u003e\n\u003cp\u003eOne with a 1.85 mm V connector at the antenna end, rated to 70 GHz.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eHow Is the PowerLOG 50700 Mounted?\u003c\/h3\u003e\n\u003cp\u003eOn the supplied aluminium mounting bracket.\u003c\/p\u003e\n\u003cp\u003e\u003csmall\u003eAnswered by John Legg, Director, Debug Store\u003c\/small\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eLast reviewed: 31 October 2026\u003c\/small\u003e\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003csmall\u003eSources (2 manufacturer documents)\u003c\/small\u003e\u003c\/summary\u003e\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/aaronia\/205-007\/aaronia-powerlog-50700-technical-datasheet.pdf\"\u003eAaronia PowerLOG 50700 technical datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/files.thedebugstore.com\/aaronia\/205-007\/aaronia-powerlog-50700-user-information.pdf\"\u003eAaronia PowerLOG 50700 user information (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/details\u003e","brand":"Aaronia AG","offers":[{"title":"Default Title","offer_id":57631092310391,"sku":"205\/007","price":0.95,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/thedebugstore.com\/en-de\/products\/aaronia-powerlog-50700-205-007","provider":"Debug Store","version":"1.0","type":"link"}