How Does The Ambient 15 Click Board™ Work?

The Ambient 15 Click Board™ as its foundation uses the TSL2584TSV, a high sensitivity light-to-digital converter that transforms light intensity into a digital output signal from AMS-AG. Thanks to its near-photopic response, the TSL2584TSV can detect a wide range of highly accurate lux measurements up to 33klx, even when mounted behind dark glass. Filtering out unwanted IR light enables the sensor to accurately measure the ambient light, thus producing a near-photopic response. It also has stable performance over a wide temperature range of -40°C to 85°C, suitable for measuring the present ambient light.

The TSL2584TSV combines one broadband photodiode (visible plus infrared), one infrared-responding photodiode, and, as mentioned before, a photopic infrared-blocking filter on a single CMOS integrated circuit. Two integrating analog-to-digital converters (ADC) convert the photodiode currents into a digital output representing the irradiance measured on each channel. Integration of both channels occurs simultaneously. Upon completion of the conversion cycle, the conversion result is transferred to the Channel 0 and Channel 1 data registers. The transfers are double-buffered to ensure that the integrity of the data is maintained. After the transfer, the device automatically begins the next integration cycle.

The Ambient 15 Click Board™ communicates with MCU using the standard I2C 2-Wire interface to read data and configure settings, supporting Standard Mode operation with a clock frequency of 100kHz and Fast Mode up to 400kHz. Besides, the TSL2584TSV allows choosing the least significant bit (LSB) of its I2C slave address using the SMD jumper labelled ADDR SEL. It also possesses an additional interrupt signal, routed on the INT pin of the mikroBUS™ socket labelled as INT, indicating when a specific interrupt event occurs, such as detecting a meaningful change in light intensity.

The Ambient 15 Click Board™ can be operated only with a 3.3V logic voltage level. The board must perform appropriate logic voltage level conversion before using MCUs with different logic levels. However, the Click board™ comes equipped with a library containing functions and an example code that can be used, as a reference, for further development.

SPECIFICATIONS

Type Optical
Applications The Ambient 15 Click Board™ be used for obtaining ambient light data for adjusting brightness in applications that require power saving and better visibility
On-board modules TSL2584TSV - high sensitivity light-to-digital converter that transforms light intensity into a digital output signal from AMS-AG
Key Features Low power consumption, corresponds to a dark window because of high sensitivity, close responsivity to the human eye, I2C interface with selectable slave address, wide illumination range, stable performance over temperature, and more
Interface I2C
Compatibility mikroBUS
Click board size S (28.6 x 25.4 mm)
Input Voltage 3.3V

PINOUT DIAGRAM

This table shows how the pinout of the Ambient 15 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

Notes Pin Pin Notes
NC 1 AN PWM 16 NC
NC 2 RST INT 15 INT Interrupt
NC 3 CS RX 14 NC
NC 4 SCK TX 13 NC
NC 5 MISO SCL 12 SCL I2C Clock
NC 6 MOSI SDA 11 SDA I2C Data
Power Supply 3.3V 7 3.3V 5V 10 NC
Ground GND 8 GND GND 9 GND Ground

ONBOARD SETTINGS AND INDICATORS

Label Name Default Description
LD1 PWR - Power LED Indicator
JP1 ADDR SEL Left I2C Address Selection 0/1: Left position 0, Right position 1

AMBIENT 15 CLICK ELECTRICAL SPECIFICATIONS

Description Min Typ Max Unit
Supply Voltage - 3.3 - V
Illuminance Measurement Range 0 - 33.000 lx
Operating Temperature Range -40 +25 +85 °C