MIKROE-1978
Regular price
£18.20
Sale price
£18.20
Regular price
£26.00
Sold out
Unit price
Quantity must be 1 or more

The Weather Click Board™ carries BME280 integrated environmental unit from Bosch. It's a sensor that detects humidity, pressure, and temperature, specifically designed for low current consumption and long-term stability. The click is designed to work on a 3.3V power supply. It communicates with the target microcontroller over SPI or I2C interface.

BME280 Features

The BME280 is as combined digital humidity, pressure and temperature sensor based on proven sensing principles.

The BME280 IC has high accuracy and reliability for all three sensors. The humidity sensor has a response time of just one second and it's accurate up to ±3% RH. The pressure sensor has sensitivity error of ±0.25% which is equivalent to 1m at 400m height change). The humidity and pressure sensors can operate independently from each other. Finally, the temperature sensor has a high resolution (up to 20 bit, when IIR filter is enabled) and low noise. The chip has three operating modes: sleep, forced, and normal.

SPECIFICATIONS

Type Environmental
Applications Context awareness, home automation control, personalized weather stations, sport and fitness tools and so on
On-board modules Bosch BME280
Key Features Three sensors in one: pressure, humidity, temperature. Humidity sensor response time: 1 sec. Multiple operating modes: sleep, force, normal
Interface I2C,SPI
Compatibility mikroBUS
Click board size S (28.6 x 25.4 mm)
Input Voltage 3.3V

PINOUT DIAGRAM

This table shows how the pinout of the Weather Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

Notes Pin Pin Notes
NC 1 AN PWM 16 NC
NC 2 RST INT 15 NC
Chip select CS 3 CS TX 14 NC
SPI clock SCK 4 SCK RX 13 NC
SPI Master Input Slave Output MISO 5 MISO SCL 12 SCL I2C Clock
SPI Master Output Slave Input MOSI 6 MOSI SDA 11 SDA I2C Data
Power supply +3.3V 7 3.3V 5V 10 NC
Ground GND 8 GND GND 9 GND Ground

JUMPERS AND SETTINGS

Designator Name Default Position Default Option Description
JP1, JP2, JP3 and JP5 Interface Selection Right I2C Jumpers for selection between I2C or SPI communications
JP4 ADDR Left Bit 0 I2C Address bit = 0