# Title: RS485 6 Click Board™ ## Description: How Does The RS485 6 Click Board™ Work? The RS485 6 Click Board™ is designed to offer you easy usage and testing of the THVD1429DT half-duplex RS485 transceiver. One of the most important features is surge protection which is achieved by integrating transient voltage suppressor (TVS) diodes in the package. This feature provides a substantial increase in reliability for better immunity to noise transients coupled to the data cable, eliminating the need for external protection components. An RS-485 bus consists of multiple transceivers connecting in parallel to a bus cable. To eliminate line reflections, each cable end is terminated with a termination resistor whose value matches the characteristic impedance of the cable. This method, known as parallel termination, allows for higher data rates over longer cable length. This device supports up to 256 Bus Nodes in one network with higher data rates up to 20 Mbps, in cases where the interconnect is short enough (or has suitably low attenuation at signal frequencies) to not degrade the data. The THVD1329DT supports several functional modes that can be selected by using RE and DE pins on the mikroBUS connector. To know more how to use these modes take a look at the "Device Functional Modes" table below. For communication with the RS485 6 Click standard UART communication can be used. This device offer several protections for the pins connected to a bus line, such as: Electrostatic Discharge (ESD) Protection against ±16-kV HBM and ±8-kV contact discharge, Electrical Fast Transient (EFT) Protection where inductive loads such as relays, switch contactors, or heavy-duty motors can create high-frequency bursts during transition and Surge transients that often result from lightning strikes (direct strike or an indirect strike which induce voltages and currents), or the switching of power systems, including load changes and short circuit switching. These transients are often encountered in industrial environments, such as factory automation and power-grid systems. Since this device feature a wide common-mode voltage range which makes them suitable for multi-point applications over long cable runs. The RS485 6 Click Board™ can be supplied and interfaced with both 3.3V and 5V without the need for any external components. The onboard SMD jumper labeled as VCC SEL allows voltage selection for interfacing with both 3.3V and 5V microcontrollers. SPECIFICATIONS Type RS485 Applications This device is perfectly suitable for wireless infrastructure, building automation, HVAC systems or factory automation, smart meters. On-board modules THVD1329DT a half-duplex RS-485 communication with integrated surge protection from Texas Instruments Key Features Surge protection on the RS485 Line, up to 256 nodes, signaling rate of up to 20 Mbps. Interface UART Compatibility mikroBUS Click board size S (28.6 x 25.4 mm) Input Voltage 3.3V or 5V PINOUT DIAGRAM This table shows how the pinout on the RS485 6 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns). Notes Pin Pin Notes NC 1 AN PWM 16 NC NC 2 RST INT 15 DE Driver enable(active hight) Receiver Enable RE 3 CS RX 14 TXD UART transmit NC 4 SCK TX 13 RXD UART Receive NC 5 MISO SCL 12 NC NC 6 MOSI SDA 11 NC Power Supply 3.3V 7 3.3V 5V 10 5V Power Supply Ground GND 8 GND GND 9 GND Ground RS485 6 CLICK ELECTRICAL SPECIFICATIONS Description Min Typ Max Unit Supply Voltage Range -0.5 - 7 V Signaling Rate - - 20 Mbps Bus Voltage -15 - 15 V Receiver Output Current -24 - 24 mA Electrostatic Discharge - +/-16 - kV DEVICE FUNCIONAL MODES INPUT ENABLE OUTPUTS FUNCTION D DE A B H H H L Active drive bus hight L H L H Active drive bus low X L Z Z Drive disabled X OPEN Z Z Driver disabled by default OPEN H H L Actively drive bus high by default ONBOARD SETTINGS AND INDICATORS Label Name Default Description LD1 PWR - Power LED indicator JP2 VCC SEL Left Power supply voltage selection: left position 3V3, right position 5V ## Product type: Click Board ## Vendor: Mikroelektronika d.o.o. ## Tags: Click Board, Interface, MikroE, RS-485, Serial Interface ## Price range: 13.3 - 13.3 GBP ## Link: https://thedebugstore.com/products/rs485-6-click-board-mikroe-3993-uk ## Compare-at price range: 19.0 - 19.0 GBP ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Mikroelektronika d.o.o. (MikroE)](https://thedebugstore.com/a/llms/collections/mikroelektronika-catalogue-uk) - [Serial Interface Click Boards™](https://thedebugstore.com/a/llms/collections/serial-interface-click-boards-catalogue) - [MikroE Click Boards™](https://thedebugstore.com/a/llms/collections/mikroe-click-boards-catalogue-uk) - [Interface Click Boards™](https://thedebugstore.com/a/llms/collections/interface-click-boards-catalogue) - [RS-485 Interface Click Boards™](https://thedebugstore.com/a/llms/collections/rs-485-interface-click-boards-catalogue) - [Click Boards™ Summer Sale](https://thedebugstore.com/a/llms/collections/inventory-sale) - [MikroE Sale](https://thedebugstore.com/a/llms/collections/mikroe-sale) - [MIKROE Stock](https://thedebugstore.com/a/llms/collections/mikroe-products-in-stock-sale) ## Variants - Default Title, SKU: MIKROE-3993, Available: yes, Inventory: 1 ## Metafields - full_description:

How Does The RS485 6 Click Board™ Work?

The RS485 6 Click Board™ is designed to offer you easy usage and testing of the THVD1429DT half-duplex RS485 transceiver. One of the most important features is surge protection which is achieved by integrating transient voltage suppressor (TVS) diodes in the package. This feature provides a substantial increase in reliability for better immunity to noise transients coupled to the data cable, eliminating the need for external protection components.

RS485 6 Click Board™

An RS-485 bus consists of multiple transceivers connecting in parallel to a bus cable. To eliminate line reflections, each cable end is terminated with a termination resistor whose value matches the characteristic impedance of the cable. This method, known as parallel termination, allows for higher data rates over longer cable length. This device supports up to 256 Bus Nodes in one network with higher data rates up to 20 Mbps, in cases where the interconnect is short enough (or has suitably low attenuation at signal frequencies) to not degrade the data.

The THVD1329DT supports several functional modes that can be selected by using RE and DE pins on the mikroBUS connector. To know more how to use these modes take a look at the "Device Functional Modes" table below. For communication with the RS485 6 Click standard UART communication can be used.

This device offer several protections for the pins connected to a bus line, such as: Electrostatic Discharge (ESD) Protection against ±16-kV HBM and ±8-kV contact discharge, Electrical Fast Transient (EFT) Protection where inductive loads such as relays, switch contactors, or heavy-duty motors can create high-frequency bursts during transition and Surge transients that often result from lightning strikes (direct strike or an indirect strike which induce voltages and currents), or the switching of power systems, including load changes and short circuit switching. These transients are often encountered in industrial environments, such as factory automation and power-grid systems.

Since this device feature a wide common-mode voltage range which makes them suitable for multi-point applications over long cable runs. The RS485 6 Click Board™ can be supplied and interfaced with both 3.3V and 5V without the need for any external components. The onboard SMD jumper labeled as VCC SEL allows voltage selection for interfacing with both 3.3V and 5V microcontrollers.

SPECIFICATIONS

Type RS485
Applications This device is perfectly suitable for wireless infrastructure, building automation, HVAC systems or factory automation, smart meters.
On-board modules THVD1329DT a half-duplex RS-485 communication with integrated surge protection from Texas Instruments
Key Features Surge protection on the RS485 Line, up to 256 nodes, signaling rate of up to 20 Mbps.
Interface UART
Compatibility mikroBUS
Click board size S (28.6 x 25.4 mm)
Input Voltage 3.3V or 5V

 

PINOUT DIAGRAM

This table shows how the pinout on the RS485 6 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

Notes Pin Mikrobus logo.png Pin Notes
  NC 1 AN PWM 16 NC  
  NC 2 RST INT 15 DE Driver enable(active hight)
Receiver Enable RE 3 CS RX 14 TXD UART transmit
  NC 4 SCK TX 13 RXD UART Receive
  NC 5 MISO SCL 12 NC  
  NC 6 MOSI SDA 11 NC  
Power Supply 3.3V 7 3.3V 5V 10 5V Power Supply
Ground GND 8 GND GND 9 GND Ground

RS485 6 CLICK ELECTRICAL SPECIFICATIONS

Description Min Typ Max Unit
Supply Voltage Range -0.5 - 7 V
Signaling Rate - - 20 Mbps
Bus Voltage -15 - 15 V
Receiver Output Current -24 - 24 mA
Electrostatic Discharge - +/-16 - kV

DEVICE FUNCIONAL MODES

INPUT ENABLE OUTPUTS FUNCTION
D DE A B
H H H L Active drive bus hight
L H L H Active drive bus low
X L Z Z Drive disabled
X OPEN Z Z Driver disabled by default
OPEN H H L Actively drive bus high by default

ONBOARD SETTINGS AND INDICATORS

Label Name Default  Description
LD1 PWR - Power LED indicator
JP2 VCC SEL Left Power supply voltage selection: left position 3V3, right position 5V

 

- description_tag: The RS485 6 Click Board™ offers a half-duplex RS-485 communication with integrated surge protection, which can be used as an interface between the TTL level UART and the RS485 communication bus. Available from Debug Store UK. - title_tag: MikroE RS485 6 Click Board™ (MIKROE-3993) - manufacturer: Mikroelektronika d.o.o. - warranty: 12 months - amazon_enable: TRUE - amazon_title: RS485 6 Click Board - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: FALSE - amazon_search: MikroElektronika Microelectronica MIKROE-1100 - amazon_uk_price: 14.08 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 15.9104 - amazon_fr_currency: EUR - amazon_fr_price: 15.9104 - amazon_es_currency: EUR - amazon_es_price: 15.9104 - amazon_nl_currency: EUR - amazon_nl_price: 15.9104 - amazon_it_currency: EUR - amazon_it_price: 15.9104 - amazon_se_curency: SEK - amazon_se_price: 160.512 - amazon_product_id: 8606018718429 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: The RS485 6 Click Board™ offers a half-duplex RS-485 communication with integrated surge protection, which can be used as an interface between the TTL level UART and the RS485 communication bus. It is based on THVD1429DT, a transceiver from Texas Instruments with signalling rate of up to 20 Mbps. This device features a wide common-mode voltage range from 3.3V to 5V, which makes it suitable for multi-point applications over long cable runs and noisy areas thanks to the integrated transient voltage suppressor (TVS) diodes in. This device and type of network is perfectly suitable for wireless infrastructure, building automation, HVAC systems or factory automation, and many more.RS485 6 Click is supported by a mikroSDK compliant library, which includes functions that simplify software development. This Click board™ comes as a fully tested product, ready to be used on a system equipped with the mikroBUS™ socket. - amazon_main_image: https://www.thedebugstore.com/images/product/lg-rs485-6-click-front.jpg - amazon_other_image_1: https://www.thedebugstore.com/images/product/lg-rs485-6-click-back.jpg - amazon_other_image_2: https://www.thedebugstore.com/images/product/lg-rs485-6-click-fusion.jpg - amazon_other_image_3: https://www.thedebugstore.com/images/product/lg-rs485-6-click-shuttle.jpg - amazon_other_image_4: https://www.thedebugstore.com/images/product/lg-rs485-6-click-clicker.jpg - amazon_other_image_5: https://www.thedebugstore.com/images/product/lg-rs485-6-click-cbreadboard.jpg - amazon_other_image_6: https://www.thedebugstore.com/images/product/lg-rs485-6-click-cbreadboard.jpg - amazon_browse_node: 428655031 - related_products: MIKROE-66,MIKROE-925,MIKROE-989,MIKROE-2700,MIKROE-2821,MIKROE-3395,MIKROE-4156,MIKROE-3863,MIKROE-2673 - mpn: MIKROE-3993 - backorder_label: If no stock shown above, check availability - badge: - widget:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
- google_product_category: 2082 - examples:

We provide a library for the RS485 6 Click on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

Library provides functions for communication via UART module, and control over RE and DE pins.

Key Functions

Example Description

The application is composed of three sections :

void application_task ( )
{
 char tmp;
 if ( app_mode == APP_MODE_RECEIVER )
 {
 // RECEIVER - UART polling
 rs4856_re_pin_set( RS4856_PIN_STATE_LOW );
 rs4856_de_pin_set( RS4856_PIN_STATE_LOW );
 drdy_flag = rs4856_byte_ready( );
 if ( 1 == drdy_flag )
 {
 tmp = rs4856_read_byte( );
 mikrobus_logWrite( &tmp, _LOG_BYTE );
 }
 }
 else
 {
 // TRANSMITTER - TX each 2 sec
 rs4856_re_pin_set( RS4856_PIN_STATE_HIGH );
 rs4856_de_pin_set( RS4856_PIN_STATE_HIGH );
 for ( tmp = 0; tmp < 9; tmp++ )
 {
 rs4856_write_byte( demo_message_data[ tmp ] );
 }
 Delay_ms( 2000 );
 }
}

The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

Additional Notes and Information

Depending on the development board you are using, you may need USB UART click, USB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

MIKROSDK

The RS485 6 Click Board™ is supported with mikroSDK - MikroElektronika Software Development Kit. To ensure proper operation of mikroSDK compliant Click board™ demo applications, mikroSDK should be downloaded from the LibStock and installed for the compiler you are using.

- attachments: [{"download_file":[{"download_file":"RS485 6 Click Board™ Schematic"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Texas Instruments THVD1429DT USRT to RS485 Transceiver Datasheet"}],"download_filetype":[{"download_filetype":"pdf"}]}] - condition: new - custom_product: false - mpn: MIKROE-3993 - google_product_category: Electronics - custom_label_0: Click Board - device_vendor: Texas Instruments - device_type: THVD1429DT - warranty: 12 months - brand: MikroE - manufacturer: Mikroelektronika d.o.o. - target_keyword: RS485 6 Click Board - brands: gid://shopify/Metaobject/56256004319 - breadcrumbs: ["gid://shopify/Collection/447955239135","gid://shopify/Collection/241680580797","gid://shopify/Collection/241546100925"] - customhs_code: 847330 - detailed_description: {"type":"root","children":[{"type":"heading","level":3,"children":[{"type":"text","value":"How Does The RS485 6 Click Board™ Work?"}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"RS485 6 Click Board™","bold":true,"italic":true},{"type":"text","value":" is designed to offer you easy usage and testing of the THVD1429DT half-duplex RS485 transceiver. One of the most important features is surge protection which is achieved by integrating transient voltage suppressor (TVS) diodes in the package. This feature provides a substantial increase in reliability for better immunity to noise transients coupled to the data cable, eliminating the need for external protection components."}]},{"type":"paragraph","children":[{"type":"text","value":""}]},{"type":"paragraph","children":[{"type":"text","value":"An RS-485 bus consists of multiple transceivers connecting in parallel to a bus cable. To eliminate line reflections, each cable end is terminated with a termination resistor whose value matches the characteristic impedance of the cable. This method, known as parallel termination, allows for higher data rates over longer cable length. This device supports up to 256 Bus Nodes in one network with higher data rates up to 20 Mbps, in cases where the interconnect is short enough (or has suitably low attenuation at signal frequencies) to not degrade the data."}]},{"type":"paragraph","children":[{"type":"text","value":"The THVD1329DT supports several functional modes that can be selected by using RE and DE pins on the mikroBUS connector. To know more how to use these modes take a look at the \"Device Functional Modes\" table below. For communication with the RS485 6 Click standard UART communication can be used."}]},{"type":"paragraph","children":[{"type":"text","value":"This device offer several protections for the pins connected to a bus line, such as: "},{"type":"text","value":"Electrostatic Discharge (ESD)","bold":true},{"type":"text","value":" Protection against ±16-kV HBM and ±8-kV contact discharge, "},{"type":"text","value":"Electrical Fast Transient (EFT)","bold":true},{"type":"text","value":" Protection where inductive loads such as relays, switch contactors, or heavy-duty motors can create high-frequency bursts during transition and "},{"type":"text","value":"Surge ","bold":true},{"type":"text","value":"transients that often result from lightning strikes (direct strike or an indirect strike which induce voltages and currents), or the switching of power systems, including load changes and short circuit switching. These transients are often encountered in industrial environments, such as factory automation and power-grid systems."}]},{"type":"paragraph","children":[{"type":"text","value":"Since this device feature a wide common-mode voltage range which makes them suitable for multi-point applications over long cable runs. The "},{"type":"text","value":"RS485 6 Click Board™","bold":true},{"type":"text","value":" can be supplied and interfaced with both 3.3V and 5V without the need for any external components. The onboard SMD jumper labeled as VCC SEL allows voltage selection for interfacing with both 3.3V and 5V microcontrollers."}]},{"type":"heading","level":3,"children":[{"type":"text","value":"SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Type\nRS485\nApplications\nThis device is perfectly suitable for wireless infrastructure, building automation, HVAC systems or factory automation, smart meters.\nOn-board modules\nTHVD1329DT a half-duplex RS-485 communication with integrated surge protection from Texas Instruments\nKey Features\nSurge protection on the RS485 Line, up to 256 nodes, signaling rate of up to 20 Mbps.\nInterface\nUART\nCompatibility\nmikroBUS\nClick board size\nS (28.6 x 25.4 mm)\nInput Voltage\n3.3V or 5V"}]},{"type":"paragraph","children":[{"type":"text","value":" "}]},{"type":"heading","level":3,"children":[{"type":"text","value":"PINOUT DIAGRAM"}]},{"type":"paragraph","children":[{"type":"text","value":"This table shows how the pinout on the "},{"type":"text","value":"RS485 6 Click Board™","bold":true},{"type":"text","value":" corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns)."}]},{"type":"paragraph","children":[{"type":"text","value":"Notes\nPin\nPin\nNotes\nNC\n1\nAN\nPWM\n16\nNC\nNC\n2\nRST\nINT\n15\nDE\nDriver enable(active hight)\nReceiver Enable\nRE\n3\nCS\nRX\n14\nTXD\nUART transmit\nNC\n4\nSCK\nTX\n13\nRXD\nUART Receive\nNC\n5\nMISO\nSCL\n12\nNC\nNC\n6\nMOSI\nSDA\n11\nNC\nPower Supply\n3.3V\n7\n3.3V\n5V\n10\n5V\nPower Supply\nGround\nGND\n8\nGND\nGND\n9\nGND\nGround"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"RS485 6 CLICK ELECTRICAL SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Description\nMin\nTyp\nMax\nUnit\nSupply Voltage Range\n-0.5\n-\n7\nV\nSignaling Rate\n-\n-\n20\nMbps\nBus Voltage\n-15\n-\n15\nV\nReceiver Output Current\n-24\n-\n24\nmA\nElectrostatic Discharge\n-\n+/-16\n-\nkV"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"DEVICE FUNCIONAL MODES"}]},{"type":"paragraph","children":[{"type":"text","value":"INPUT\nENABLE\nOUTPUTS\nFUNCTION\nD\nDE\nA\nB\nH\nH\nH\nL\nActive drive bus hight\nL\nH\nL\nH\nActive drive bus low\nX\nL\nZ\nZ\nDrive disabled\nX\nOPEN\nZ\nZ\nDriver disabled by default\nOPEN\nH\nH\nL\nActively drive bus high by default"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"ONBOARD SETTINGS AND INDICATORS"}]},{"type":"paragraph","children":[{"type":"text","value":"Label\nName\nDefault\n Description\nLD1\nPWR\n-\nPower LED indicator\nJP2\nVCC SEL\nLeft\nPower supply voltage selection: left position 3V3, right position 5V"}]},{"type":"heading","level":3,"children":[{"type":"text","value":" "}]}]} - summary:

The RS485 6 Click Board™ offers a half-duplex RS-485 communication with integrated surge protection, which can be used as an interface between the TTL level UART and the RS485 communication bus. It is based on THVD1429DT, a transceiver from Texas Instruments with a signalling rate of up to 20 Mbps. This device features a wide common-mode voltage range from 3.3V to 5V, which makes it suitable for multi-point applications over long cable runs and noisy areas thanks to the integrated transient voltage suppressor (TVS) diodes. This device and type of network is perfectly suitable for wireless infrastructure, building automation, HVAC systems or factory automation, and many more.

The RS485 6 Click is supported by a mikroSDK compliant library, which includes functions that simplify software development. This Click Board™ comes as a fully tested product, ready to be used on a system equipped with the mikroBUS™ socket.