# Title: Hantek MSO-5202D Mixed Signal Oscilloscope, 2-ch, 200MHz, 16-LA ## Description: Features 200/100/60MHz bandwidth 1GSa/s Real Time sample rate Large (7.0-inch) color display,WVGA(800x480) Record length up to 1M Trigger mode: edge/pulse width/line selectable video/slop/overtime etc. USB host and device connectivity, standard Multiple automatic measurements Four math functions, including FFTs standard VGA Optional Specifications Model MSO5202D MSO5102D MSO5062D Acquisition Sample Rate Real-Time Sample: 1GS/s Acquisition Modes Normal Normal data only Peak Detect High-frequency and randon glith capture Average Waveform Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inputs Impendance 1MΩ±2% ‖20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal Sample Rate Range 500MS/s--1GS/s Waveform Interpolation (sin x)/x Record Length 1M SEC/DIV Range 2ns/div to 40s/div, 8ns/div to 40s/div Sample Rate and Delay Time Accuracy ±50ppm(at over any ≥1ms time interval) Position Range 2ns/div to 8ns/div; (-8div x s/div) to 20ms; 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s; Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 Vertical System Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 10V/div Bandwidth 200MHz 100MHz 60MHz Rise Time at BNC( typical) 1.8ns 3.5ns 5.8ns Offset Range 2mV/div to 20mV/div, ±400mV 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V 5V/div to 10V/div, ±50V Math +, -, *, /, FFT FFT Windows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80KHz; LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz Trigger Level Range CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); Set Level to 50%(typical) Operates with input signals ≥50Hz Video Trigger Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. Time Range 20ns ~ 10s Overtime Trigger Over Time Mode Rising edge or Falling edge Time Range 20ns ~ 10s Alternative Trigger Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger Frequency Counter Readout Resolution 6 digits Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors) Frequency Range AC coupled, from 4Hz minimum to rated bandwidth Signal Source Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. Measurement Cursor Measurement Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT) Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF Logic Analyzer Specifications Channels 16 Channels Max. Input Impendence 200K(C=10p) Input Voltage Range -60V~60V Logic Threshold Range -8V~8V Max. Sample Rate 500MHz Compatible Input TTL, CMOS, ECL Sample Depth 512K Trigger Edge Trigger D0-D15 select slope (rising or falling edge) Pulse Width D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width Code-type D0-D15 select code-type (H, L, X) Duration D0-D15 select persist time and trigger when (data terminate, data start, and data delay) Queue D0-D15 select specific data index (0-3) and code-type (H, L, X) Repeat D0-D15 select code-type (H, L, X) and repeat times General Specifications Display Display Type 7 inch 64K color TFT (diagonal liquid crystal) Display Resolution 800 horizontal by 480 vertical pixels Display Contrast Adjustable (16 gears) with the progress bar Probe Compensator Output Output Voltage( typical) About 5Vpp into ≥1MΩ load Frequency(typical) 1kHz Power Supply Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ Power Consumption <30W Fuse 2A, T rating, 250V Environmental Temperature Operating: 32℉ to 122℉ (0℃ to 50℃); Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃) Cooling Method Convection Humidity +104℉ or below (+40℃ or below): ≤90% relative humidity; 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity Altitude Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet) Size & Weight Size 385mm x 200mm x 245mm Weight 2.08KG(without Packing) ## Product type: Oscilloscope ## Vendor: Hantek Electronic Co Ltd ## Tags: Bench, Hantek, hantek-electronic-co-ltd, Mixed Signal Oscilloscope, Multifunction, Oscilloscope ## Price range: 460.0 - 460.0 GBP ## Link: https://thedebugstore.com/products/mso-5202d-oscilloscope-hantek-uk ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Oscilloscopes](https://thedebugstore.com/a/llms/collections/oscilloscopes-catalogue-uk) - [Hantek Electronic Co. Ltd](https://thedebugstore.com/a/llms/collections/hantek-electronic-catalogue) - [Mixed Signal Oscilloscopes](https://thedebugstore.com/a/llms/collections/mixed-signal-oscilloscopes-catalogue) - [Admin: No Inventory](https://thedebugstore.com/a/llms/collections/no-inventory) - [Bench Oscilloscopes](https://thedebugstore.com/a/llms/collections/bench-oscilloscopes-catalogue) - [Multifunction Oscilloscopes](https://thedebugstore.com/a/llms/collections/multifunction-oscilloscopes-catalogue) - [Hantek Mixed Signal Oscilloscope](https://thedebugstore.com/a/llms/collections/hantek-mixed-signal-oscilloscopes) ## Variants - Default Title, SKU: MSO-5202D, Available: no, Inventory: 0 ## Metafields - full_description:

Features

Specifications

Model MSO5202D MSO5102D MSO5062D
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Waveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inputs Impendance 1MΩ±2% ‖20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
 CAT III: 150VRMS (1×);
 Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
Record Length 1M
SEC/DIV Range 2ns/div to 40s/div,  8ns/div to 40s/div
Sample Rate and
 Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range 2ns/div to 8ns/div; 
 (-8div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
 200us/div to 40s/div; (-8div x s/div) to 400s;
Delta Time Measurement Accuracy 
 (Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
 >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
 Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 10V/div
Bandwidth 200MHz 100MHz 60MHz
Rise Time at BNC( typical) 1.8ns 3.5ns 5.8ns
Offset Range

2mV/div to 20mV/div, ±400mV

 

50mV/div to 200mV/div, ±2V

 

500mV/div to 2V/div, ±40V

 5V/div to 10V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
 ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
 Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
 When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability, 
 Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
 (Edge Trigger Type)
DC(CH1,CH2):
 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
 DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
 DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      
 AC: Attenuates signals below 10Hz           
 HF Reject: Attenuates signals above 80KHz; 
 LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
 EXT: ±1.2V;
 EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
 EXT: ± (6% of setting + 40mV);
 EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions;
 EXT: 400mV;
 EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
 Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
 Less than: The trigger point is the trailing edge.
 Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
 Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
 Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
 Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
 The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
 Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
 Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
 Video Trigger mode: The Frequency Counter does not work.
Measurement
Cursor Measurement Voltage difference between cursors: △V
 Time difference between cursors: △T
 Reciprocal of △T in Hertz (1/ΔT)
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF

Logic Analyzer Specifications

Channels 16 Channels
Max. Input Impendence 200K(C=10p)
Input Voltage Range -60V~60V
Logic Threshold Range -8V~8V
Max. Sample Rate 500MHz
 Compatible Input TTL, CMOS, ECL
Sample Depth 512K
Trigger
Edge Trigger D0-D15 select slope (rising or falling edge)
Pulse Width D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
Code-type D0-D15 select code-type (H, L, X)
Duration D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
Queue D0-D15 select specific data index (0-3) and code-type (H, L, X)
Repeat D0-D15 select code-type (H, L, X) and repeat times

General Specifications

Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Temperature Operating: 32℉ to 122℉ (0℃ to 50℃);
 Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling Method Convection
Humidity +104℉ or below (+40℃ or below): ≤90% relative humidity;
 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
 Nonoperaring: Below 15,000m(50,000 feet)
Size & Weight
Size 385mm x 200mm x 245mm
Weight 2.08KG(without Packing)
- description_tag: Buy your Hantek 2-ch, 200MHz, 16-ch, 1GSa/s Benchtop MSO. UK Stock with Free UK and EU Shipping - title_tag: Hantek MSO-5202D 2-ch 200MHz Mixed Signal Scope - manufacturer: Hantek Electronic Co Ltd - warranty: 12 months - amazon_enable: TRUE - amazon_title: Hantek MSO-5202D Mixed Signal Oscilloscope, 2-ch, 200MHz, 16-LA - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: TRUE - amazon_search: Hantek Oscilloscope - amazon_uk_price: 495 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 559.35 - amazon_fr_currency: EUR - amazon_fr_price: 559.35 - amazon_es_currency: EUR - amazon_es_price: 559.35 - amazon_nl_currency: EUR - amazon_nl_price: 559.35 - amazon_it_currency: EUR - amazon_it_price: 559.35 - amazon_se_curency: SEK - amazon_se_price: 5643 - amazon_product_id: 5055383626816 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: Hantek MSO-5202D 2-ch, 200MHz, 16-ch, 1GSa/s Benchtop MSO - amazon_long_description:

Specifications

Oscilloscope

ModelMSO5202DMSO5102DMSO5062D
Acquisition
Sample RateReal-Time Sample: 1GS/s
Acquisition Modes
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWaveform Average, selectable 4,8,16,32,64,128
Inputs
Inputs CouplingAC, DC, GND
Inputs Impendance1MΩ±2% 20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;
 CAT III: 150VRMS (1×);
 Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range500MS/s--1GS/s
Waveform Interpolation(sin x)/x
Record Length1M
SEC/DIV Range2ns/div to 40s/div, 8ns/div to 40s/div
Sample Rate and
 Delay Time Accuracy
±50ppmat over any ≥1ms time interval)
Position Range2ns/div to 8ns/div; 
 (-8div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
 200us/div to 40s/div; (-8div x s/div) to 400s;
Delta Time Measurement Accuracy 
 (Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
 >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
 Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 10V/div
Bandwidth200MHz100MHz60MHz
Rise Time at BNC( typical)1.8ns3.5ns5.8ns
Offset Range 

2mV/div to 20mV/div, ±400mV

 

50mV/div to 200mV/div, ±2V

 

500mV/div to 2V/div, ±40V

 5V/div to 10V/div, ±50V
Math+, -, *, /, FFT
FFTWindows: HanningFlatopRectamgularBartlettBlackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
 ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
 Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
 When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability, 
 Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
 (Edge Trigger Type)
DC(CH1,CH2):
 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
 DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
 DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      
 AC: Attenuates signals below 10Hz           
 HF Reject: Attenuates signals above 80KHz; 
 LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen; 
 EXT: ±1.2V;
 EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20nsCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
 EXT: ± (6% of setting + 40mV);
 EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions;
 EXT: 400mV;
 EXT/5: 2V
Signal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger PointEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
 Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
 Less than: The trigger point is the trailing edge.
 Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range20ns ~ 10s
Slope Trigger
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
 Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
 Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
 Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Overtime Trigger
Over Time ModeRising edge or Falling edge
Time Range20ns ~ 10s
Alternative Trigger
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution6 digits
Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
 The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
 Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
 Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
 Video Trigger mode: The Frequency Counter does not work.
Measurement
Cursor MeasurementVoltage difference between cursors: V
 Time difference between cursors: 
T
 Reciprocal of 
T in Hertz (1/ΔT)
Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF

Logic Analyzer Specifications

Channels16 Channels
Max. Input Impendence200K(C=10p)
Input Voltage Range-60V~60V
Logic Threshold Range-8V~8V
Max. Sample Rate500MHz
 Compatible InputTTL, CMOS, ECL
Sample Depth512K
Trigger
Edge TriggerD0-D15 select slope (rising or falling edge)
Pulse WidthD0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
Code-typeD0-D15 select code-type (H, L, X)
DurationD0-D15 select persist time and trigger when (data terminate, data start, and data delay)
QueueD0-D15 select specific data index (0-3) and code-type (H, L, X)
RepeatD0-D15 select code-type (H, L, X) and repeat times

General Specifications

Display
Display Type7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution800 horizontal by 480 vertical pixels
Display ContrastAdjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)About 5Vpp into ≥1MΩ load
Frequency(typical)1kHz
Power Supply
Supply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CAT
 120-240VACRMS(±10%), 45Hz to 66Hz, CAT
Power Consumption<30W
Fuse2A, T rating, 250V
Environmental
TemperatureOperating: 32 to 122 (0 to 50);
 Nonoperating: -40
 to 159.8 (-40 to +71)
Cooling MethodConvection
Humidity+104 or below (+40 or below): ≤90% relative humidity;
 106
 to 122 (+41 to 50): ≤60% relative humidity
AltitudeOperating: Below 3,000m (10,000 feet);
 Nonoperaring: Below 15,000m(50,000 feet)
Size & Weight
Size385mm x 200mm x 245mm
Weight2.08KG(without Packing
- amazon_main_image: https://www.thedebugstore.com/images/product/lg-hantek-mso5202d_2.jpg - amazon_browse_node: 428655031 - mpn: MSO-5202D - backorder_label: If no stock is shown above, order now and we'll ship within 10 working days. - attachment_url_1: https://www.thedebugstore.com/files/attachments/11384/user-manual-mso-5000D.pdf - attachment_title_1: Hantek MSO-5062D Oscilloscope User Manual - google_product_category: 345 - custom_label_1: Scope - condition: new - custom_product: false - mpn: MSO-5202D - google_product_category: Electronics - custom_label_0: Oscilloscope - warranty: 12 months - brand: Hantek - manufacturer: Hantek Electronic Co Ltd - badge: - widget:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
- brands: gid://shopify/Metaobject/56254759135 - breadcrumbs: ["gid://shopify/Collection/267180835005","gid://shopify/Collection/240413933757"] - bandwidth: 200MHz - analog_channels: 2 - customhs_code: 903040 - detailed_description: {"type":"root","children":[{"type":"heading","level":2,"children":[{"type":"text","value":"Features"}]},{"type":"list","listType":"unordered","children":[{"type":"list-item","children":[{"type":"text","value":"200/100/60MHz bandwidth"}]},{"type":"list-item","children":[{"type":"text","value":"1GSa/s Real Time sample rate"}]},{"type":"list-item","children":[{"type":"text","value":"Large (7.0-inch) color display,WVGA(800x480)"}]},{"type":"list-item","children":[{"type":"text","value":"Record length up to 1M"}]},{"type":"list-item","children":[{"type":"text","value":"Trigger mode: edge/pulse width/line selectable video/slop/overtime etc."}]},{"type":"list-item","children":[{"type":"text","value":"USB host and device connectivity, standard"}]},{"type":"list-item","children":[{"type":"text","value":"Multiple automatic measurements"}]},{"type":"list-item","children":[{"type":"text","value":"Four math functions, including FFTs standard"}]},{"type":"list-item","children":[{"type":"text","value":"VGA Optional"}]}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Specifications"}]},{"type":"paragraph","children":[{"type":"text","value":"Model\nMSO5202D\nMSO5102D\nMSO5062D\nAcquisition\nSample Rate\nReal-Time Sample: 1GS/s\nAcquisition Modes\nNormal\nNormal data only\nPeak Detect\nHigh-frequency and randon glith capture\nAverage\nWaveform Average, selectable 4,8,16,32,64,128\nInputs\nInputs Coupling\nAC, DC, GND\nInputs Impendance\n1MΩ±2% ‖20pF±3pF\nProbe Attenuation\n1X, 10X\nSupported Probe Attenuation Factor\n1X, 10X, 100X, 1000X\nMaximum Input Voltage\nCAT I and CAT II: 300VRMS (10×), Installation Category;\n  CAT III: 150VRMS (1×);\n  Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.\nHorizontal\nSample Rate Range\n500MS/s--1GS/s\nWaveform Interpolation\n(sin x)/x\nRecord Length\n1M\nSEC/DIV Range\n2ns/div to 40s/div, \n8ns/div to 40s/div\nSample Rate and\n  Delay Time Accuracy\n±50ppm(at over any ≥1ms time interval)\nPosition Range\n2ns/div to 8ns/div; \n  (-8div x s/div) to 20ms;\n20ns/div to 80us/div; (-8div x s/div) to 40ms;\n  200us/div to 40s/div; (-8div x s/div) to 400s;\nDelta Time Measurement Accuracy \n  (Full Bandwidth)\nSingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);\n  >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);\n  Sample interval = s/div ÷ 200\nVertical System\nVertical Resolution\n8-bit resolution, all channel sampled simultaneously\nPosition Range\n2mV/div to 10V/div\nBandwidth\n200MHz\n100MHz\n60MHz\nRise Time at BNC( typical)\n1.8ns\n3.5ns\n5.8ns\nOffset Range\n2mV/div to 20mV/div, ±400mV\n  \n\n 50mV/div to 200mV/div, ±2V\n  \n\n 500mV/div to 2V/div, ±40V\n  5V/div to 10V/div, ±50V\nMath\n+, -, *, /, FFT\nFFT\nWindows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point\nBandwidth Limit\n20MHz\nLow Frequency Response (-3db)\n≤10Hz at BNC\nDC Gain Accuracy\n±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;\n  ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div\nDC Measurement Accuracy, \n  Average Acquisition Mode\nWhen vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; \n  When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div\nVolts Measurement Repeatability, \n  Average Acquisition Mode\nDelta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions\nTrigger System\nTrigger Types\nEdge, Video, Pulse, Slope, Over time, Alternative\nTrigger Source\nCH1, CH2, EXT, EXT/5, AC Line\nTrigger Modes\nAuto, Normal, Single\nCoupling Type\nDC, AC, Noise Reject, HF Reject, LF Reject\nTrigger Sensitivity\n  (Edge Trigger Type)\nDC(CH1,CH2):\n  1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;\n  DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;\n  DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      \n  AC: Attenuates signals below 10Hz           \n  HF Reject: Attenuates signals above 80KHz; \n  LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz\nTrigger Level Range\nCH1/CH2: ±8 divisions from center of screen; \n  EXT: ±1.2V;\n  EXT/5:±6V\nTrigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns\nCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;\n  EXT: ± (6% of setting + 40mV);\n  EXT/5: ± (6% of setting + 200mV);\nSet Level to 50%(typical)\nOperates with input signals ≥50Hz\nVideo Trigger\nVideo Trigger Type \nCH1, CH2: Peak-to-peak amplitude of 2 divisions;\n  EXT: 400mV;\n  EXT/5: 2V\nSignal Formats and Field Rates, Video Trigger Type\nSupports NTSC, PAL and SECAM broadcast systems for any field or any line\nHoldoff Range\n100ns ~ 10s\nPulse Width Trigger\nPulse Width Trigger Mode\nTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse\nPulse Width Trigger Point\nEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.\n  Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.\n  Less than: The trigger point is the trailing edge.\n  Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width\nPulse Width Range\n20ns ~ 10s\nSlope Trigger\nSlope Trigger Mode\nTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope\nSlope Trigger Point\nEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.\n  Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.\n  Less than: The oscilloscope triggers when the waveform slope is less than the set slope.\n  Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.\nTime Range\n20ns ~ 10s\nOvertime Trigger\nOver Time Mode\nRising edge or Falling edge\nTime Range\n20ns ~ 10s\nAlternative Trigger\nTrigger on CH1\nInternal Trigger: Edge, Pulse Width, Video, Slope\nTrigger on CH2\nInternal Trigger: Edge, Pulse Width, Video, Slope\nTrigger Frequency Counter\nReadout Resolution\n6 digits\nAccuracy (typical)\n±30ppm (including all frequency reference errors and ±1 count errors)\nFrequency Range\nAC coupled, from 4Hz minimum to rated bandwidth\nSignal Source\nPulse Width or Edge Trigger modes: all available trigger sources\n  The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.\n  Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.\n  Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.\n  Video Trigger mode: The Frequency Counter does not work.\nMeasurement\nCursor Measurement\nVoltage difference between cursors: △V\n  Time difference between cursors: △T\n  Reciprocal of △T in Hertz (1/ΔT)\nAuto Measuerment\nFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF\nLogic Analyzer Specifications\nChannels\n16 Channels\nMax. Input Impendence\n200K(C=10p)\nInput Voltage Range\n-60V~60V\nLogic Threshold Range\n-8V~8V\nMax. Sample Rate\n500MHz\n Compatible Input\nTTL, CMOS, ECL\nSample Depth\n512K\nTrigger\nEdge Trigger\nD0-D15 select slope (rising or falling edge)\nPulse Width\nD0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width\nCode-type\nD0-D15 select code-type (H, L, X)\nDuration\nD0-D15 select persist time and trigger when (data terminate, data start, and data delay)\nQueue\nD0-D15 select specific data index (0-3) and code-type (H, L, X)\nRepeat\nD0-D15 select code-type (H, L, X) and repeat times\nGeneral Specifications\nDisplay\nDisplay Type\n7 inch 64K color TFT (diagonal liquid crystal)\nDisplay Resolution\n800 horizontal by 480 vertical pixels\nDisplay Contrast\nAdjustable (16 gears) with the progress bar\nProbe Compensator Output\nOutput Voltage( typical)\nAbout 5Vpp into ≥1MΩ load\nFrequency(typical)\n1kHz\nPower Supply\nSupply Voltage\n100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ\n  120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ\nPower Consumption\n<30W\nFuse\n2A, T rating, 250V\nEnvironmental\nTemperature\nOperating: 32℉ to 122℉ (0℃ to 50℃);\n  Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)\nCooling Method\nConvection\nHumidity\n+104℉ or below (+40℃ or below): ≤90% relative humidity;\n  106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity\nAltitude\nOperating: Below 3,000m (10,000 feet);\n  Nonoperaring: Below 15,000m(50,000 feet)\nSize & Weight\nSize\n385mm x 200mm x 245mm\nWeight\n2.08KG(without Packing)"}]}]} - summary:

Mixed Signal Oscilloscope;
Bandwidth:60-200MHz;
Real Time Sample Rate:1GSa/s;Record Length: 1M;
Large (7.0-inch) color display,WVGA(800x480);
16 channels Logic Analyzer,500MSa/s sample rate;
Power Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.SO