# Title: Oximeter 3 Click Board™ ## Description: How Does The Oximeter 3 Click Board™ Work? The Oximeter 3 Click Board™ is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor. The VCNL4020C-GS08 sensor comes with a built-in infrared emitter, and signal processing IC in a single package with a 16 bit ADC. It also has an ambient light PIN photodiode with close-to-human-eye sensitivity with excellent ambient light suppression through signal modulation. For biosensor functionality, it converts the current from the PIN photodiode to a 16-bit digital data output value, while for the ambient light sensing it converts the current from the ambient light detector, amplifies it, and converts it to a 16-bit digital output stream. The integrated infrared emitter has a peak wavelength of 890 nm. It emits light that reflects off an object within 20 cm of the sensor and has a programmable drive current from 10 mA to 200 mA in 10 mA steps. The built-in infrared emitter and broader sensitivity photodiode also can work with the additional on-board green LED and IRLED as designed on this Click board™. As an additional light source true green color LED (VLMTG1300) with a 525nm peak wavelength is used, alongside an infrared dual-color emitting diode (VSMD66694) with 660 nm and 940 nm peak wavelength well suited for measuring the optical pulse oximetry. The PIN photodiode receives the light that is reflected off the object and converts it to a current. It has a peak sensitivity of 890 nm, matching the peak wavelength of the emitter, and it is insensitive to ambient light. The VCNL4020C also provides ambient light sensing to support conventional backlight and display brightness auto-adjustment. The ambient light sensor receives the visible light and converts it to a current, and it has peak sensitivity at 540 nm and bandwidth from 430 nm to 610 nm. The Oximeter 3 Click Board™ communicates with the MCU using the standard I2C 2-wire interface with fixed slave address compatible with all I2C modes (Standard, Fast, and High-Speed). It allows easy access to a biosensor signal and light intensity measurements without complex calculations or programming. It also generates programmable interrupt signal routed on the INT pin of the mikroBUS™, that offers Wake-Up functionality for the MCU when a proximity event or ambient light change occurs, which reduces processing overhead by eliminating the need for continuous polling. The Oximeter 3 Click Board™ is designed to be operated with both 3.3V and 5V logic voltage levels that can be selected via VCC SEL jumper. This allows for both 3.3V and 5V capable MCUs to use the I2C communication lines properly. SPECIFICATIONS Type Biometrics Applications Can be used for applications such as optical pulse oximetry and health monitoring. On-board modules The Oximeter 3 Click Board™ is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor. Key Features Low current consumption, onboard LEDs optimized for the oximetry measurements, high frequency bursts for biosensor signal measurement, programmable interrupt function, and more. Interface I2C Compatibility mikroBUS Click board size S (28.6 x 25.4 mm) Input Voltage 3.3V or 5V PINOUT DIAGRAM This table shows how the pinout of the Oximeter 3 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns). Notes Pin Pin Notes NC 1 AN PWM 16 NC NC 2 RST INT 15 INT Interrupt NC 3 CS RX 14 NC NC 4 SCK TX 13 NC NC 5 MISO SCL 12 SCL I2C Clock NC 6 MOSI SDA 11 SDA I2C Data Power Supply 3.3V 7 3.3V 5V 10 5V Power Supply Ground GND 8 GND GND 9 GND Ground ONBOARD SETTINGS AND INDICATORS Label Name Default Description LD1 PWR - Power LED Indicator LD2 VLMTG1300 - Green Measurement LED IR1 VSMD66694 - Infrared Measurement LED JP1 VCC SEL Left Power Supply Voltage Selection 3V3/5V: Left position 3V3, Right position 5V OXIMETER 3 CLICK ELECTRICAL SPECIFICATIONS Description Min Typ Max Unit Supply Voltage -0.3 - 5.5 V Ambient Light Resolution - 0.25 - Ik IR1 Infrared Wavelenght 660 - 940 nm LD2 Green LED Wavelenght - 525 - nm Operating Temperature Range -25 - +85 V ## Product type: Click Board ## Vendor: Mikroelektronika d.o.o. ## Tags: Biometric, Click Board, MikroE, Sensor, Vishay Semiconductor Opto Division ## Price range: 12.6 - 12.6 GBP ## Link: https://thedebugstore.com/products/mikroe-4267-oximeter-3-click-board-uk ## Compare-at price range: 18.0 - 18.0 GBP ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Mikroelektronika d.o.o. (MikroE)](https://thedebugstore.com/a/llms/collections/mikroelektronika-catalogue-uk) - [Vishay Sensors Device Support: Development Boards and Tools](https://thedebugstore.com/a/llms/collections/devices-vishay-sensors) - [Sensor Click Boards™](https://thedebugstore.com/a/llms/collections/sensor-click-boards-catalogue) - [MikroE Click Boards™](https://thedebugstore.com/a/llms/collections/mikroe-click-boards-catalogue-uk) - [Biometric Click Boards™](https://thedebugstore.com/a/llms/collections/biometrics-click-boards-catalogue) - [Click Boards™ Summer Sale](https://thedebugstore.com/a/llms/collections/inventory-sale) - [MikroE Sale](https://thedebugstore.com/a/llms/collections/mikroe-sale) - [MIKROE Stock](https://thedebugstore.com/a/llms/collections/mikroe-products-in-stock-sale) ## Variants - Default Title, SKU: MIKROE-4267, Available: yes, Inventory: 1 ## Metafields - full_description:

How Does The Oximeter 3 Click Board™ Work?

The Oximeter 3 Click Board™ is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor. The VCNL4020C-GS08 sensor comes with a built-in infrared emitter, and signal processing IC in a single package with a 16 bit ADC. It also has an ambient light PIN photodiode with close-to-human-eye sensitivity with excellent ambient light suppression through signal modulation. For biosensor functionality, it converts the current from the PIN photodiode to a 16-bit digital data output value, while for the ambient light sensing it converts the current from the ambient light detector, amplifies it, and converts it to a 16-bit digital output stream.

oximeter 3 Click Board™

The integrated infrared emitter has a peak wavelength of 890 nm. It emits light that reflects off an object within 20 cm of the sensor and has a programmable drive current from 10 mA to 200 mA in 10 mA steps. The built-in infrared emitter and broader sensitivity photodiode also can work with the additional on-board green LED and IRLED as designed on this Click board™. As an additional light source true green color LED (VLMTG1300) with a 525nm peak wavelength is used, alongside an infrared dual-color emitting diode (VSMD66694) with 660 nm and 940 nm peak wavelength well suited for measuring the optical pulse oximetry.

The PIN photodiode receives the light that is reflected off the object and converts it to a current. It has a peak sensitivity of 890 nm, matching the peak wavelength of the emitter, and it is insensitive to ambient light. The VCNL4020C also provides ambient light sensing to support conventional backlight and display brightness auto-adjustment. The ambient light sensor receives the visible light and converts it to a current, and it has peak sensitivity at 540 nm and bandwidth from 430 nm to 610 nm.

The Oximeter 3 Click Board™ communicates with the MCU using the standard I2C 2-wire interface with fixed slave address compatible with all I2C modes (Standard, Fast, and High-Speed). It allows easy access to a biosensor signal and light intensity measurements without complex calculations or programming. It also generates programmable interrupt signal routed on the INT pin of the mikroBUS™, that offers Wake-Up functionality for the MCU when a proximity event or ambient light change occurs, which reduces processing overhead by eliminating the need for continuous polling.

The Oximeter 3 Click Board™ is designed to be operated with both 3.3V and 5V logic voltage levels that can be selected via VCC SEL jumper. This allows for both 3.3V and 5V capable MCUs to use the I2C communication lines properly.

SPECIFICATIONS

Type Biometrics
Applications Can be used for applications such as optical pulse oximetry and health monitoring.
On-board modules The Oximeter 3 Click Board™ is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor.
Key Features Low current consumption, onboard LEDs optimized for the oximetry measurements, high frequency bursts for biosensor signal measurement, programmable interrupt function, and more.
Interface I2C
Compatibility mikroBUS
Click board size S (28.6 x 25.4 mm)
Input Voltage 3.3V or 5V

PINOUT DIAGRAM

This table shows how the pinout of the Oximeter 3 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

Notes Pin Mikrobus logo.png Pin Notes
NC 1 AN PWM 16 NC
NC 2 RST INT 15 INT Interrupt
NC 3 CS RX 14 NC
NC 4 SCK TX 13 NC
NC 5 MISO SCL 12 SCL I2C Clock
NC 6 MOSI SDA 11 SDA I2C Data
Power Supply 3.3V 7 3.3V 5V 10 5V Power Supply
Ground GND 8 GND GND 9 GND Ground

ONBOARD SETTINGS AND INDICATORS

Label Name Default Description
LD1 PWR - Power LED Indicator
LD2 VLMTG1300 - Green Measurement LED
IR1 VSMD66694 - Infrared Measurement LED
JP1 VCC SEL Left Power Supply Voltage Selection 3V3/5V: Left position 3V3, Right position 5V

OXIMETER 3 CLICK ELECTRICAL SPECIFICATIONS

Description Min Typ Max Unit
Supply Voltage -0.3 - 5.5 V
Ambient Light Resolution - 0.25 - Ik
IR1 Infrared Wavelenght 660 - 940 nm
LD2 Green LED Wavelenght - 525 - nm
Operating Temperature Range -25 - +85 V

 

- description_tag: The Oximeter 3 Click Board™ is a compact add-on board perfectly suited for measuring the blood oxygen saturation. This board features the VCNL4020C-GS08, a fully integrated high-resolution digital biosensor from Vishay Semiconductors. Available from Debug Store UK. - title_tag: MikroE Oximeter 3 Click Board™ (MIKROE-4267) - manufacturer: Mikroelektronika d.o.o. - warranty: 12 months - amazon_enable: TRUE - amazon_title: Oximeter 3 Click Board - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: FALSE - amazon_search: MikroElektronika Microelectronica MIKROE-1100 - amazon_uk_price: 13.2 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 14.916 - amazon_fr_currency: EUR - amazon_fr_price: 14.916 - amazon_es_currency: EUR - amazon_es_price: 14.916 - amazon_nl_currency: EUR - amazon_nl_price: 14.916 - amazon_it_currency: EUR - amazon_it_price: 14.916 - amazon_se_curency: SEK - amazon_se_price: 150.48 - amazon_product_id: 8606018718924 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: The Oximeter 3 Click Board™ is a compact add-on board perfectly suited for measuring the blood oxygen saturation. This board features the VCNL4020C-GS08, a fully integrated high-resolution digital biosensor from Vishay Semiconductors. It combines an infrared emitter and PIN photodiode for biosensor functionality, ambient light sensor, and signal processing IC in a single package with a 16-bit ADC. It supports standard I2C serial digital interface and has the programmable interrupt function that offers wake-up functionality when a proximity event or ambient light change occurs. This Click board™ makes it an excellent choice for applications such as optical pulse oximetry and health monitoring.Oximeter 3 Click is supported by a mikroSDK compliant library, which includes functions that simplify software development. This Click board™ comes as a fully tested product, ready to be used on a system equipped with the mikroBUS™ socket. - amazon_main_image: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-front.jpg - amazon_other_image_1: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-back.jpg - amazon_other_image_2: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-fusion.jpg - amazon_other_image_3: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-shuttle.jpg - amazon_other_image_4: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-clicker.jpg - amazon_other_image_5: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-breadboard.jpg - amazon_other_image_6: https://www.thedebugstore.com/images/product/lg-oximeter-3-click-breadboard.jpg - amazon_browse_node: 428655031 - related_products: MIKROE-3827,MIKROE-4153,MIKROE-3869 - mpn: MIKROE-4267 - backorder_label: If no stock shown above, check availability - badge: - widget:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
- condition: new - custom_product: false - mpn: MIKROE-4267 - google_product_category: Electronics - custom_label_0: Click Board - examples:

We provide a library for the Oximeter 3 Click Board™ on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

Library provides generic functions for reading and writing data to register and getting INT pin status. There is one specific function that reads data from sensor and returns it, which data returns depends on input parameter.

Key Functions

Example Description

The application is composed of three sections :

void application_task ( )
{
 if ( OXIMETER3_HEART_RATE == dev_mode )
 {
 rd_val = oximeter3_read_value( OXIMETER3_PROX );
 WordToStr( rd_val, demo_txt );
 mikrobus_logWrite( demo_txt, _LOG_TEXT );
 mikrobus_logWrite( ",", _LOG_LINE );
 Delay_ms( 3 );
 }
 else
 {
 rd_val = oximeter3_read_value( OXIMETER3_PROX );
 WordToStr( rd_val, demo_txt );
 mikrobus_logWrite( " * Proximity: ", _LOG_TEXT );
 mikrobus_logWrite( demo_txt, _LOG_LINE );
 rd_val = oximeter3_read_value( OXIMETER3_ALS );
 WordToStr( rd_val, demo_txt );
 mikrobus_logWrite( " * ALS: ", _LOG_TEXT );
 mikrobus_logWrite( demo_txt, _LOG_LINE );
 mikrobus_logWrite( "********************", _LOG_LINE );
 Delay_ms( 500 );
 }
}

The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

Additional Notes and Information

Depending on the development board you are using, you may need USB UART Click Board™, USB UART 2 Click Board™ or RS232 Click Board™ to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

MIKROSDK

The Oximeter 3 Click Board™ is supported with mikroSDK - MikroElektronika Software Development Kit. To ensure proper operation of mikroSDK compliant Click board™ demo applications, mikroSDK should be downloaded from the LibStock and installed for the compiler you are using.

- attachments: [{"download_file":[{"download_file":"Oximeter 3 Click Board™ Schematic"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Vishay VSMD66694 Dual Colour LED Datasheet"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Vishay VCNL4020C-GS08 Biosensor Datasheet"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Vishay VLMTG1300 LED Datasheet"}],"download_filetype":[{"download_filetype":"pdf"}]}] - device_vendor: Vishay Semiconductor Opto Division - device_type: VCNL4020C-GS08, VLMTG1300-GS08, VSMD66694 - warranty: 12 months - brand: MikroE - key_feature_1: Measurement of Blood-Oxygen Saturation - manufacturer: Mikroelektronika d.o.o. - target_keyword: Oximeter 3 Click Board - brands: gid://shopify/Metaobject/56256004319 - breadcrumbs: ["gid://shopify/Collection/447955239135","gid://shopify/Collection/241680580797","gid://shopify/Collection/241545969853"] - customhs_code: 847330 - detailed_description: {"type":"root","children":[{"type":"heading","level":3,"children":[{"type":"text","value":"How Does The Oximeter 3 Click Board™ Work?"}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Oximeter 3 Click Board™","bold":true,"italic":true},{"type":"text","value":" is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor. The VCNL4020C-GS08 sensor comes with a built-in infrared emitter, and signal processing IC in a single package with a 16 bit ADC. It also has an ambient light PIN photodiode with close-to-human-eye sensitivity with excellent ambient light suppression through signal modulation. For biosensor functionality, it converts the current from the PIN photodiode to a 16-bit digital data output value, while for the ambient light sensing it converts the current from the ambient light detector, amplifies it, and converts it to a 16-bit digital output stream."}]},{"type":"paragraph","children":[{"type":"text","value":""}]},{"type":"paragraph","children":[{"type":"text","value":"The integrated infrared emitter has a peak wavelength of 890 nm. It emits light that reflects off an object within 20 cm of the sensor and has a programmable drive current from 10 mA to 200 mA in 10 mA steps. The built-in infrared emitter and broader sensitivity photodiode also can work with the additional on-board green LED and IRLED as designed on this Click board™. As an additional light source true green color LED (VLMTG1300) with a 525nm peak wavelength is used, alongside an infrared dual-color emitting diode (VSMD66694) with 660 nm and 940 nm peak wavelength well suited for measuring the optical pulse oximetry."}]},{"type":"paragraph","children":[{"type":"text","value":"The PIN photodiode receives the light that is reflected off the object and converts it to a current. It has a peak sensitivity of 890 nm, matching the peak wavelength of the emitter, and it is insensitive to ambient light. The VCNL4020C also provides ambient light sensing to support conventional backlight and display brightness auto-adjustment. The ambient light sensor receives the visible light and converts it to a current, and it has peak sensitivity at 540 nm and bandwidth from 430 nm to 610 nm."}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Oximeter 3 Click Board™","bold":true},{"type":"text","value":" communicates with the MCU using the standard I2C 2-wire interface with fixed slave address compatible with all I2C modes (Standard, Fast, and High-Speed). It allows easy access to a biosensor signal and light intensity measurements without complex calculations or programming. It also generates programmable interrupt signal routed on the INT pin of the mikroBUS™, that offers Wake-Up functionality for the MCU when a proximity event or ambient light change occurs, which reduces processing overhead by eliminating the need for continuous polling."}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Oximeter 3 Click Board™","bold":true},{"type":"text","value":" is designed to be operated with both 3.3V and 5V logic voltage levels that can be selected via VCC SEL jumper. This allows for both 3.3V and 5V capable MCUs to use the I2C communication lines properly."}]},{"type":"heading","level":3,"children":[{"type":"text","value":"SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Type\nBiometrics\nApplications\nCan be used for applications such as optical pulse oximetry and health monitoring.\nOn-board modules\nThe Oximeter 3 Click Board™ is based on the VCNL4020C-GS08, a fully integrated biosensor and ambient light sensor with an I2C interface from Vishay Semiconductor.\nKey Features\nLow current consumption, onboard LEDs optimized for the oximetry measurements, high frequency bursts for biosensor signal measurement, programmable interrupt function, and more.\nInterface\nI2C\nCompatibility\nmikroBUS\nClick board size\nS (28.6 x 25.4 mm)\nInput Voltage\n3.3V or 5V"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"PINOUT DIAGRAM"}]},{"type":"paragraph","children":[{"type":"text","value":"This table shows how the pinout of the "},{"type":"text","value":"Oximeter 3 Click Board™","bold":true},{"type":"text","value":" corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns)."}]},{"type":"paragraph","children":[{"type":"text","value":"Notes\nPin\nPin\nNotes\nNC\n1\nAN\nPWM\n16\nNC\nNC\n2\nRST\nINT\n15\nINT\nInterrupt\nNC\n3\nCS\nRX\n14\nNC\nNC\n4\nSCK\nTX\n13\nNC\nNC\n5\nMISO\nSCL\n12\nSCL\nI2C Clock\nNC\n6\nMOSI\nSDA\n11\nSDA\nI2C Data\nPower Supply\n3.3V\n7\n3.3V\n5V\n10\n5V\nPower Supply\nGround\nGND\n8\nGND\nGND\n9\nGND\nGround"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"ONBOARD SETTINGS AND INDICATORS"}]},{"type":"paragraph","children":[{"type":"text","value":"Label\nName\nDefault\nDescription\nLD1\nPWR\n-\nPower LED Indicator\nLD2\nVLMTG1300\n-\nGreen Measurement LED\nIR1\nVSMD66694\n-\nInfrared Measurement LED\nJP1\nVCC SEL\nLeft\nPower Supply Voltage Selection 3V3/5V: Left position 3V3, Right position 5V"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"OXIMETER 3 CLICK ELECTRICAL SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Description\nMin\nTyp\nMax\nUnit\nSupply Voltage\n-0.3\n-\n5.5\nV\nAmbient Light Resolution\n-\n0.25\n-\nIk\nIR1 Infrared Wavelenght\n660\n-\n940\nnm\nLD2 Green LED Wavelenght\n-\n525\n-\nnm\nOperating Temperature Range\n-25\n-\n+85\nV"}]},{"type":"heading","level":3,"children":[{"type":"text","value":" "}]}]} - summary:

The Oximeter 3 Click Board™ is a compact add-on board perfectly suited for measuring the blood oxygen saturation. This board features the VCNL4020C-GS08, a fully integrated high-resolution digital biosensor from Vishay Semiconductors. It combines an infrared emitter and PIN photodiode for biosensor functionality, ambient light sensor, and signal processing IC in a single package with a 16-bit ADC. It supports standard I2C serial digital interface and has the programmable interrupt function that offers wake-up functionality when a proximity event or ambient light change occurs. This Click Board™ makes it an excellent choice for applications such as optical pulse oximetry and health monitoring.

The Oximeter 3 Click Board™ is supported by a mikroSDK compliant library, which includes functions that simplify software development. This Click Board™ comes as a fully tested product, ready to be used on a system equipped with the mikroBUS™ socket.