# Title: Hall Current 4 Click Board™ ## Description: DO NOT TOUCH THE BOARD WHILE THE EXTERNAL POWER SUPPLY IS ON! Note: Voltage higher than 50V can be hazardous! The click is to be used by trained personnel only and attention when applying high voltage is strongly adviced. Due to the fact that the sensor provides a solely analog voltage at its output which is linearly commensurate to the current through the load connected to the output terminal, the Hall Current 4 Click Board™ also has the integrated analog-digital converter which serves to transform the output voltage from the ACS70331 to digital value. The digital value is possible to read from the I2C interface. How Does The Hall Current 4 Click Board™ Work? The Hall Current 4 Click Board™ uses the ACS70331 current sensor produced by Allegro, and the 12-bit ADC marked MCP3221, produced by Microchip. The ACS70331 uses GMR elements to indirectly measure the current flowing through the primary conductor of the IC, by sensing the field produced by this current. This IC utilizes the fact that the field generated by the current passing through the primary conductor affects the voltage across the GMR sensor. The GMR sensor voltage cahnges even with a very low field strength, which makes the ACS70331 very suitable for accurate measurements of lower currents. However, the saturation happens quite soon after, making it unsuitable for higher currents. The ACS70331 has the sensitivity of 200 mV/A and can measure the current in the range range from -5A to +5A Considering that the operative range of the ACS70331 is approximately 1 MHz, the variations of the output voltage with the load current are quite fast with no latency. The output voltage from the ACS70331 is fed to the input of the analog-digital converter (ADC) which which allows reading the conversion data via the I2C interface. The ACS70331 has a small primary conductor resistance of 1.1 mΩ, resulting in low power dissipation and consequently low temperature rise due to current flow through the sensor. The sensor has no physical contact with the output pins on the chip as it operates exclusively by the principle of the filed generated by the current which runs through the input pins (primary conductor). The load voltage at the input pins is isolated from the rest of the chip. However, it is not safe to use at the voltages higher than 100V. SPECIFICATIONS Type Current sensor Applications The Hall Current 4 Click Board™ is perfect for various applications designed for current sensing, e.g. monitoring the current in battery chargers, or for the various kinds of system power supplies, etc. On-board modules IC ACS70331, high sensitivity GMR-based current sensor IC, by Allegro Key Features Very low serial resistance, measurement of relatively high voltage values – up to 5A independent from the polarization, great accuracy thanks to the GSR current sensor, big range of power supply voltages to which the load can be amounted, etc. Interface I2C Compatibility mikroBUS Click board size M (42.9 x 25.4 mm) Input Voltage 3.3V or 5V PINOUT DIAGRAM This table shows how the pinout on the Hall Current 4 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns). Notes Pin Pin Notes NC 1 AN PWM 16 NC NC 2 RST INT 15 NC NC 3 CS RX 14 NC NC 4 SCK TX 13 NC NC 5 MISO SCL 12 SCL I2C Clock NC 6 MOSI SDA 11 SDA I2C Data Power supply 3V3 7 3.3V 5V 10 +5V Power Supply Ground GND 8 GND GND 9 GND Ground ONBOARD SETTINGS AND INDICATORS Label Name Default Description VCC SEL VCC SEL Left Logic voltage level selection: left position 3.3V, right position 5V PWR PWR - Power LED indicator HALL CURRENT 4 CLICK ELECTRICAL SPECIFICATIONS Description Min Typ Max Unit Current range -5 - +5 A Allowed voltage across the input terminal 0 - 100 V ## Product type: Click Board ## Vendor: Mikroelektronika d.o.o. ## Tags: Allegro Microsystems, Ammeter, Click Board, Current, MikroE, Sensor ## Price range: 15.4 - 15.4 GBP ## Link: https://thedebugstore.com/products/mikroe-3308-hall-current-4-click-board-uk ## Compare-at price range: 22.0 - 22.0 GBP ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Mikroelektronika d.o.o. (MikroE)](https://thedebugstore.com/a/llms/collections/mikroelektronika-catalogue-uk) - [Allegro MicroSystems Device Support: Development Boards & Tools](https://thedebugstore.com/a/llms/collections/allegro-microsystems-device-support-uk) - [Sensor Click Boards™](https://thedebugstore.com/a/llms/collections/sensor-click-boards-catalogue) - [MikroE Click Boards™](https://thedebugstore.com/a/llms/collections/mikroe-click-boards-catalogue-uk) - [Current Sensor Click Boards™](https://thedebugstore.com/a/llms/collections/current-sensor-click-boards-catalogue) - [Click Boards™ Summer Sale](https://thedebugstore.com/a/llms/collections/inventory-sale) - [MikroE Sale](https://thedebugstore.com/a/llms/collections/mikroe-sale) - [MIKROE Stock](https://thedebugstore.com/a/llms/collections/mikroe-products-in-stock-sale) ## Variants - Default Title, SKU: MIKROE-3308, Available: yes, Inventory: 1 ## Metafields - full_description:

DO NOT TOUCH THE BOARD WHILE THE EXTERNAL POWER SUPPLY IS ON!

Note: Voltage higher than 50V can be hazardous! The click is to be used by trained personnel only and attention when applying high voltage is strongly adviced.

Due to the fact that the sensor provides a solely analog voltage at its output which is linearly commensurate to the current through the load connected to the output terminal, the Hall Current 4 Click Board™ also has the integrated analog-digital converter which serves to transform the output voltage from the ACS70331 to digital value. The digital value is possible to read from the I2C interface.

How Does The Hall Current 4 Click Board™ Work?

The Hall Current 4 Click Board™ uses the ACS70331 current sensor produced by Allegro, and the 12-bit ADC marked MCP3221, produced by Microchip. The ACS70331 uses GMR elements to indirectly measure the current flowing through the primary conductor of the IC, by sensing the field produced by this current. This IC utilizes the fact that the field generated by the current passing through the primary conductor affects the voltage across the GMR sensor. The GMR sensor voltage cahnges even with a very low field strength, which makes the ACS70331 very suitable for accurate measurements of lower currents. However, the saturation happens quite soon after, making it unsuitable for higher currents. The ACS70331 has the sensitivity of 200 mV/A and can measure the current in the range range from -5A to +5A

MikroElektronika Hall Current 4 click

Considering that the operative range of the ACS70331 is approximately 1 MHz, the variations of the output voltage with the load current are quite fast with no latency. The output voltage from the ACS70331 is fed to the input of the analog-digital converter (ADC) which which allows reading the conversion data via the I2C interface. The ACS70331 has a small primary conductor resistance of 1.1 mΩ, resulting in low power dissipation and consequently low temperature rise due to current flow through the sensor.

The sensor has no physical contact with the output pins on the chip as it operates exclusively by the principle of the filed generated by the current which runs through the input pins (primary conductor). The load voltage at the input pins is isolated from the rest of the chip. However, it is not safe to use at the voltages higher than 100V.

SPECIFICATIONS

Type Current sensor
Applications The Hall Current 4 Click Board™ is perfect for various applications designed for current sensing, e.g. monitoring the current in battery chargers, or for the various kinds of system power supplies, etc.
On-board modules IC ACS70331, high sensitivity GMR-based current sensor IC, by Allegro
Key Features Very low serial resistance, measurement of relatively high voltage values – up to 5A independent from the polarization, great accuracy thanks to the GSR current sensor, big range of power supply voltages to which the load can be amounted, etc.
Interface I2C
Compatibility mikroBUS
Click board size M (42.9 x 25.4 mm)
Input Voltage 3.3V or 5V

PINOUT DIAGRAM

This table shows how the pinout on the Hall Current 4 Click Board™ corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

Notes Pin Mikrobus logo.png Pin Notes
NC 1 AN PWM 16 NC
NC 2 RST INT 15 NC
NC 3 CS RX 14 NC
NC 4 SCK TX 13 NC
NC 5 MISO SCL 12 SCL I2C Clock
NC 6 MOSI SDA 11 SDA I2C Data
Power supply 3V3 7 3.3V 5V 10 +5V Power Supply
Ground GND 8 GND GND 9 GND Ground

ONBOARD SETTINGS AND INDICATORS

Label Name Default Description
VCC SEL VCC SEL Left Logic voltage level selection: left position 3.3V, right position 5V
PWR PWR - Power LED indicator


HALL CURRENT 4 CLICK ELECTRICAL SPECIFICATIONS

Description Min Typ Max Unit
Current range -5 - +5 A
Allowed voltage across the input terminal 0 - 100 V

 

- description_tag: The Hall Current 4 Click Board™ is designed to measure relatively high current by using the integrated ACS70331 sensor. The current sensor is based on the GMR elements for current measurement. Available from Debug Store UK. - title_tag: MikroE Hall Current 4 Click Board™ (MIKROE-3308) - manufacturer: Mikroelektronika d.o.o. - warranty: 12 months - amazon_enable: TRUE - amazon_title: Hall Current 4 Click Board - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: FALSE - amazon_search: MikroElektronika Microelectronica MIKROE-1100 - amazon_uk_price: 15.84 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 17.8992 - amazon_fr_currency: EUR - amazon_fr_price: 17.8992 - amazon_es_currency: EUR - amazon_es_price: 17.8992 - amazon_nl_currency: EUR - amazon_nl_price: 17.8992 - amazon_it_currency: EUR - amazon_it_price: 17.8992 - amazon_se_curency: SEK - amazon_se_price: 180.576 - amazon_product_id: 8606018714216 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: The Hall Current 4 Click Board™ is designed to measure relatively high current by using the integrated ACS70331 sensor. The current sensor is based on the GMR elements for current measurement. The Hall Current 4 can be used for current measurement in the applications designed to follow a current, such as the applications for monitoring the current in battery chargers, or for the various kinds of system power supplies. - amazon_long_description:

DO NOT TOUCH THE BOARD WHILE THE EXTERNAL POWER SUPPLY IS ON!

Note:  Voltage higher than 50V can be hazardous! The click is to be used by trained personnel only and attention when applying high voltage is strongly adviced.

Due to the fact that the sensor provides a solely analog voltage at its output which is linearly commensurate to the current through the load connected to the output terminal, the Hall Current 4 click also has the integrated analog-digital converter which serves to transform the output voltage from the ACS70331 to digital value. The digital value is possible to read from the I2C interface.

How Does The Hall Current 4 Click Board Work?

The Hall Current 4 click uses the ACS70331 current sensor produced by Allegro, and the 12-bit ADC marked MCP3221, produced by Microchip. The ACS70331 uses GMR elements to indirectly measure the current flowing through the primary conductor of the IC, by sensing the field produced by this current. This IC utilizes the fact that the field generated by the current passing through the primary conductor affects the voltage across the GMR sensor. The GMR sensor voltage changes even with a very low field strength, which makes the ACS70331 very suitable for accurate measurements of lower currents. However, the saturation happens quite soon after, making it unsuitable for higher currents. The ACS70331 has the sensitivity of 200 mV/A and can measure the current in the range range from -5A to +5A

MikroElektronika Hall Current 4 click

Considering that the operative range of the ACS70331 is approximately 1 MHz, the variations of the output voltage with the load current are quite fast with no latency. The output voltage from the ACS70331 is fed to the input of the analog-digital converter (ADC) which which allows reading the conversion data via the I2C interface. The ACS70331 has a small primary conductor resistance of 1.1 mΩ, resulting in low power dissipation and consequently low temperature rise due to current flow through the sensor.

The sensor has no physical contact with the output pins on the chip as it operates exclusively by the principle of the filed generated by the current which runs through the input pins (primary conductor). The load voltage at the input pins is isolated from the rest of the chip. However, it is not safe to use at the voltages higher than 100V.

- amazon_main_image: https://www.thedebugstore.com/images/product/lg-hall-current-4-front_1.jpg - amazon_other_image_1: https://www.thedebugstore.com/images/product/lg-hall-current-4-back_1.jpg - amazon_other_image_2: https://www.thedebugstore.com/images/product/lg-hall-current-4-click-in-use_1.jpg - amazon_other_image_3: https://www.thedebugstore.com/images/product/lg-hall-current-4-click-in-use_1.jpg - amazon_browse_node: 428655031 - related_products: MIKROE-3629 - mpn: MIKROE-3308 - backorder_label: If no stock shown above, check availability - badge: - widget:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
- google_product_category: 259 - condition: new - custom_product: false - mpn: MIKROE-3308 - google_product_category: Electronics - custom_label_0: Click Board - examples:

We provide a library for the Hall Current 4 Click Board™ on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

This library provides basic functionality for reading the current value and controlling the click board.

Key Functions

Example Description

The application is composed of the three sections :

void applicationTask()
{
 char demoText[ 50 ];
 float Current;
 Current = hallcurrent4_getCurrent();
 mikrobus_logWrite(" Current value: ", _LOG_TEXT);
 FloatToStr(Current, demoText);
 mikrobus_logWrite(demoText, _LOG_TEXT);
 mikrobus_logWrite(" mA", _LOG_LINE);
 mikrobus_logWrite(" ------------------------- ", _LOG_LINE );
 Delay_ms( 1000 );
}


The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

Additional Notes and Information

Depending on the development board you are using, you may need USB UART click, USB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

MIKROSDK

The Hall Current 4 Click Board™ is supported with mikroSDK - MikroElektronika Software Development Kit. To ensure proper operation of mikroSDK compliant click board demo applications, mikroSDK should be downloaded from the LibStock and installed for the compiler you are using.

- attachments: [{"download_file":[{"download_file":"Hall Current 4 Click Board™ Schematic"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Allegro Microsystems ACS70331 Current Sensor"}],"download_filetype":[{"download_filetype":"pdf"}]}] - warranty: 12 months - brand: MikroE - key_feature_1: High-Current Measurement - manufacturer: Mikroelektronika d.o.o. - target_keyword: Hall Current 4 Click Board - brands: gid://shopify/Metaobject/56256004319 - breadcrumbs: ["gid://shopify/Collection/447955239135","gid://shopify/Collection/241680580797","gid://shopify/Collection/241545969853"] - customhs_code: 847330 - detailed_description: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":""},{"type":"text","value":"DO NOT TOUCH THE BOARD WHILE THE EXTERNAL POWER SUPPLY IS ON!"}]},{"type":"paragraph","children":[{"type":"text","value":"Note","bold":true},{"type":"text","value":": Voltage higher than 50V can be hazardous! The click is to be used by trained personnel only and attention when applying high voltage is strongly adviced."}]},{"type":"paragraph","children":[{"type":"text","value":"Due to the fact that the sensor provides a solely analog voltage at its output which is linearly commensurate to the current through the load connected to the output terminal, the "},{"type":"text","value":"Hall Current 4 Click Board™","bold":true,"italic":true},{"type":"text","value":" also has the integrated analog-digital converter which serves to transform the output voltage from the ACS70331 to digital value. The digital value is possible to read from the I2C interface."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"How Does The Hall Current 4 Click Board™ Work?"}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Hall Current 4 Click Board™","bold":true},{"type":"text","value":" uses the ACS70331 current sensor produced by Allegro, and the 12-bit ADC marked MCP3221, produced by Microchip. The ACS70331 uses GMR elements to indirectly measure the current flowing through the primary conductor of the IC, by sensing the field produced by this current. This IC utilizes the fact that the field generated by the current passing through the primary conductor affects the voltage across the GMR sensor. The GMR sensor voltage cahnges even with a very low field strength, which makes the ACS70331 very suitable for accurate measurements of lower currents. However, the saturation happens quite soon after, making it unsuitable for higher currents. The ACS70331 has the sensitivity of 200 mV/A and can measure the current in the range range from -5A to +5A"}]},{"type":"paragraph","children":[{"type":"text","value":""}]},{"type":"paragraph","children":[{"type":"text","value":"Considering that the operative range of the ACS70331 is approximately 1 MHz, the variations of the output voltage with the load current are quite fast with no latency. The output voltage from the ACS70331 is fed to the input of the analog-digital converter (ADC) which which allows reading the conversion data via the I2C interface. The ACS70331 has a small primary conductor resistance of 1.1 mΩ, resulting in low power dissipation and consequently low temperature rise due to current flow through the sensor."}]},{"type":"paragraph","children":[{"type":"text","value":"The sensor has no physical contact with the output pins on the chip as it operates exclusively by the principle of the filed generated by the current which runs through the input pins (primary conductor). The load voltage at the input pins is isolated from the rest of the chip. However, it is not safe to use at the voltages higher than 100V."}]},{"type":"heading","level":3,"children":[{"type":"text","value":"SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Type\nCurrent sensor\nApplications\nThe Hall Current 4 Click Board™ is perfect for various applications designed for current sensing, e.g. monitoring the current in battery chargers, or for the various kinds of system power supplies, etc.\nOn-board modules\nIC ACS70331, high sensitivity GMR-based current sensor IC, by Allegro\nKey Features\nVery low serial resistance, measurement of relatively high voltage values – up to 5A independent from the polarization, great accuracy thanks to the GSR current sensor, big range of power supply voltages to which the load can be amounted, etc.\nInterface\nI2C\nCompatibility\nmikroBUS\nClick board size\nM (42.9 x 25.4 mm)\nInput Voltage\n3.3V or 5V"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"PINOUT DIAGRAM"}]},{"type":"paragraph","children":[{"type":"text","value":"This table shows how the pinout on the "},{"type":"text","value":"Hall Current 4 Click Board™","bold":true},{"type":"text","value":" corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns)."}]},{"type":"paragraph","children":[{"type":"text","value":"Notes\nPin\nPin\nNotes\nNC\n1\nAN\nPWM\n16\nNC\nNC\n2\nRST\nINT\n15\nNC\nNC\n3\nCS\nRX\n14\nNC\nNC\n4\nSCK\nTX\n13\nNC\nNC\n5\nMISO\nSCL\n12\nSCL\nI2C Clock\nNC\n6\nMOSI\nSDA\n11\nSDA\nI2C Data\nPower supply\n3V3\n7\n3.3V\n5V\n10\n+5V\nPower Supply\nGround\nGND\n8\nGND\nGND\n9\nGND\nGround"}]},{"type":"heading","level":3,"children":[{"type":"text","value":"ONBOARD SETTINGS AND INDICATORS"}]},{"type":"paragraph","children":[{"type":"text","value":"Label\nName\nDefault\nDescription\nVCC SEL\nVCC SEL\nLeft\nLogic voltage level selection: left position 3.3V, right position 5V\nPWR\nPWR\n-\nPower LED indicator"}]},{"type":"heading","level":3,"children":[{"type":"text","value":""},{"type":"text","value":"HALL CURRENT 4 CLICK ELECTRICAL SPECIFICATIONS"}]},{"type":"paragraph","children":[{"type":"text","value":"Description\nMin\nTyp\nMax\nUnit\nCurrent range\n-5\n-\n+5\nA\nAllowed voltage across the input terminal\n0\n-\n100\nV"}]},{"type":"heading","level":3,"children":[{"type":"text","value":" "}]}]} - summary:

The Hall Current 4 Click Board™ is designed to measure relatively high current by using the integrated ACS70331 sensor. The current sensor is based on the GMR elements for current measurement. The Hall Current 4 Click Board™ can be used for current measurement in the applications designed to follow a current, such as the applications for monitoring the current in battery chargers, or for the various kinds of system power supplies.