# Title: Lipowsky Baby-LIN-RM-III CAN/LIN Bus Simulator ## Description: The Baby-LIN-RM-III is a controller that can be used to control LIN or CAN interface using a standard computer. This device comes with an integrated 32-bit microcontroller that can perform all time-critical operations. LINWorks V2 Software The Baby-LIN-RM-III includes the easy-to-use LINWorks V2 software suite. Based on LDF or DBC files configurations can be set up within minutes. Each configuration can define which nodes from the bus will be simulated by the Baby-LIN-RM-III (restbus simulation) or how a change of state at the digital inputs will change bus signals or trigger a macro. Via the digital inputs PWM signals can be read, scaled and mapped to bus signals. Signal values can be read can be read and written in real-time while other operations are in progress. This can be done via a Simple Menu found in the LINWorks suite or by a custom product or even via the API functions of a supplied DLL. Operating System Compatibility The LINWorks-V2 software suite is compatible to Win-XP, Win7, Win8 and Win10 (16 and 32-bit). A Linux version is available upon request. Digital I/O Also, the module's digital outputs can be controlled by the values of the bus signals. For instance; an output can be set, if a signal is equal to, not equal to, greater or less than a reference value. It also can be tested, if a certain signal value is within a given range or not. LIN Bus Interface The implemented LIN driver supports bus voltages up to 36 volts and can be used to up to 200 Kbit/s. These way even nodes that operate outside the standard limits of the LIN specifications can be controlled with the Baby-LIN-RM-III. CAN Bus Interface One CAN interface is designed as a high-speed interface, conforming to ISO-11898 with a SN65HVD251 driver while the other interface utilises a fault-tolerant low-speed physical layer conforming to ISO-11519 with a TJA1054 transceiver. Galvanically Isolated Interfaces All communication interfaces (LIN, CAN and USB) as well as the digital inputs are galvanically isolated from the module's logic circuit. Programmable Buttons Additionally, the Baby-LIN-RM-II offers two programmable buttons that may be configured to control the start and stop functions of the bus. Stand-alone Operation The configuration designed on a computer can be transferred to and stored on the device, allowing you to use the controller as a standalone device, without any computer. Applications The Baby-LIN-RM-III makes is easy to add LIN or CAN bus communication capabilities to PLC-based test equipment such as durability test facilities, validation tests etc. The Baby-LIN-RM-II is equipped with a powerful 32-bit microcontroller that handles all time-critical operations such as message formatting and the decoding of the bus protocol. . ## Product type: Bus Simulator ## Vendor: Lipowsky Industrie Elektronik GmbH ## Tags: Bus Simulator, Host Adapter, LIN Bus, Lipowsky, lipowsky-industrie-elektronik-gmbh ## Price range: 1175.0 - 1175.0 GBP ## Link: https://thedebugstore.com/products/lipowsky-baby-lin-rm-iii-can-lin-bus-adapter-uk ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Lipowsky Industrie-Elektronik GmbH](https://thedebugstore.com/a/llms/collections/lipowsky-industrie-elektronik-catalogue) - [Admin: No Inventory](https://thedebugstore.com/a/llms/collections/no-inventory) - [Host Adapters](https://thedebugstore.com/a/llms/collections/host-adapters-catalogue) - [LIN Bus Interface (Host Adapters)](https://thedebugstore.com/a/llms/collections/lin-bus-interfaces-catalogue) - [Development Tools](https://thedebugstore.com/a/llms/collections/development-tools-catalogue-uk) - [Bus Simulators](https://thedebugstore.com/a/llms/collections/bus-simulators) ## Variants - Default Title, SKU: BABY-LIN-RM-III, Available: yes, Inventory: 0 ## Metafields - full_description:

The Baby-LIN-RM-III is a controller that can be used to control LIN or CAN interface using a standard computer. This device comes with an integrated 32-bit microcontroller that can perform all time-critical operations.

LINWorks V2 Software

The Baby-LIN-RM-III includes the easy-to-use LINWorks V2 software suite.

Based on LDF or DBC files configurations can be set up within minutes. Each configuration can define which nodes from the bus will be simulated by the Baby-LIN-RM-III (restbus simulation) or how a change of state at the digital inputs will change bus signals or trigger a macro. Via the digital inputs PWM signals can be read, scaled and mapped to bus signals.

Signal values can be read can be read and written in real-time while other operations are in progress. This can be done via a Simple Menu found in the LINWorks suite or by a custom product or even via the API functions of a supplied DLL.

Operating System Compatibility

The LINWorks-V2 software suite is compatible to Win-XP, Win7, Win8 and Win10 (16 and 32-bit). A Linux version is available upon request.

Digital I/O

Also, the module's digital outputs can be controlled by the values of the bus signals. For instance; an output can be set, if a signal is equal to, not equal to, greater or less than a reference value. It also can be tested, if a certain signal value is within a given range or not.

LIN Bus Interface

The implemented LIN driver supports bus voltages up to 36 volts and can be used to up to 200 Kbit/s. These way even nodes that operate outside the standard limits of the LIN specifications can be controlled with the Baby-LIN-RM-III.

CAN Bus Interface

One CAN interface is designed as a high-speed interface, conforming to ISO-11898 with a SN65HVD251 driver while the other interface utilises a fault-tolerant low-speed physical layer conforming to ISO-11519 with a TJA1054 transceiver.

Galvanically Isolated Interfaces

All communication interfaces (LIN, CAN and USB) as well as the digital inputs are galvanically isolated from the module's logic circuit.

Programmable Buttons

Additionally, the Baby-LIN-RM-II offers two programmable buttons that may be configured to control the start and stop functions of the bus.

Stand-alone Operation

The configuration designed on a computer can be transferred to and stored on the device, allowing you to use the controller as a standalone device, without any computer.

Applications

The Baby-LIN-RM-III makes is easy to add LIN or CAN bus communication capabilities to PLC-based test equipment such as durability test facilities, validation tests etc. The Baby-LIN-RM-II is equipped with a powerful 32-bit microcontroller that handles all time-critical operations such as message formatting and the decoding of the bus protocol.
.

- description_tag: The Lipowsky Baby-LIN-RM-III allows LIN-Bus, CAN-Bus and CAN-FD Bus-equipped devices to be controlled by a PC. The interface can simulate CAN and LIN-Bus Master and Slave nodes. Available from Debug Store UK. - title_tag: Lipowsky CAN/LIN Bus Host Adapter (Baby-LIN-RM-III) - manufacturer: Lipowsky Industrie Elektronik GmbH - warranty: 12 months - amazon_enable: TRUE - amazon_title: Lipowsky Baby-LIN-RM-III LIN Bus Adapter - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: TRUE - amazon_search: Lipowsky - amazon_uk_price: 1017.5 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 1149.775 - amazon_fr_currency: EUR - amazon_fr_price: 1149.775 - amazon_es_currency: EUR - amazon_es_price: 1149.775 - amazon_nl_currency: EUR - amazon_nl_price: 1149.775 - amazon_it_currency: EUR - amazon_it_price: 1149.775 - amazon_se_curency: SEK - amazon_se_price: 11599.5 - amazon_product_id: 5055383688678 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: The Baby-LIN-RM-III allows LIN-Bus, CAN-Bus and CAN-FD Bus equipped devices to be controlled by a PC. The interface can simulate CAN and LIN-Bus Master and Slave nodesAfter installation of the supplied LINWorks software, you can connect the Baby-LIN-RM-III to a free USB port, and access the LIN- and CAN-Bus devices via LINWorks or own programs by using the Baby-LIN-DLL. In addition LIN and CAN devices can be controlled using digital signals only. This enhances testing facilities based on a PLC (Programmable Logic Controller) by a LIN- or CAN-Bus without much effort. This can be extremely beneficial for facilities with long term testing. - amazon_long_description:

The Baby-LIN-RM-III is a controller that can be used to control LIN or CAN interface using a standard computer. This device comes with an integrated 32-bit microcontroller that can perform all time-critical operations.

LINWorks V2 Software

The Baby-LIN-RM-III includes the easy-to-use LINWorks V2 software suite.

Based on LDF or DBC files configurations can be set up within minutes. Each configuration can define which nodes from the bus will be simulated by the Baby-LIN-RM-III (restbus simulation) or how a change of state at the digital inputs will change bus signals or trigger a macro. Via the digital inputs PWM signals can be read, scaled and mapped to bus signals.

Signal values can be read can be read and written in real-time while other operations are in progress. This can be done via a Simple Menu found in the LINWorks suite or by a custom product or even via the API functions of a supplied DLL.

Operating System Compatibility

The LINWorks-V2 software suite is compatible to Win-XP, Win7, Win8 and Win10 (16 and 32-bit). A Linux version is available upon request.

Digital I/O

Also, the module's digital outputs can be controlled by the values of the bus signals. For instance; an output can be set, if a signal is equal to, not equal to, greater or less than a reference value. It also can be tested, if a certain signal value is within a given range or not.

LIN Bus Interface

The implemented LIN driver supports bus voltages up to 36 volts and can be used to up to 200 Kbit/s. These way even nodes that operate outside the standard limits of the LIN specifications can be controlled with the Baby-LIN-RM-III.

CAN Bus Interface

One CAN interface is designed as a high-speed interface, conforming to ISO-11898 with a SN65HVD251 driver while the other interface utilises a fault-tolerant low-speed physical layer conforming to ISO-11519 with a TJA1054 transceiver.

Galvanically Isolated Interfaces

All communication interfaces (LIN, CAN and USB) as well as the digital inputs are galvanically isolated from the module's logic circuit.

Programmable Buttons

Additionally, the Baby-LIN-RM-II offers two programmable buttons that may be configured to control the start and stop functions of the bus.

Stand-alone Operation

The configuration designed on a computer can be transferred to and stored on the device, allowing you to use the controller as a standalone device, without any computer.

Applications

The Baby-LIN-RMIII makes is easy to add LIN or CAN bus communication capabilities to PLC-based test equipment such as durability test facilities, validation tests etc. The Baby-LIN-RM-II is equipped with a powerful 32-bit microcontroller that handles all time-critical operations such as message formatting and the decoding of the bus protocol.
.

- amazon_main_image: https://www.thedebugstore.com/images/product/lg-lipowsky-baby-lin-rm-iii-front_1.jpg - amazon_browse_node: 428655031 - related_products: BABY-LIN-II,BABY-LIN-MB-II,BABY-LIN-RM-II,BABY-LIN-RC-II,BL-HARP-CAN-2-LS,BL-HARP-CAN-1-HS - mpn: BABY-LIN-RM-III - backorder_label: If no stock is shown above, order now and we'll ship within 3 working days. - attachment_url_1: https://thecontrol.store/files/attachments/12955/DS_Baby-LIN-RM-III_en.pdf&&https://thecontrol.store/files/attachments/12955/ApplicationNote-GettingStarted_Baby-LIN-RM-II_en.pdf - attachment_title_1: Lipowsky Baby-LIN-RM-III Datasheet&&Lipowsky Baby-LIN-RM-II Getting Started Guide - google_product_category: 2082 - attachments: [{"download_file":[{"download_file":"Lipowsky Baby-LIN-RM-III LIN Bus Adapter Datasheet"}],"download_filetype":[{"download_filetype":"pdf"}]},{"download_file":[{"download_file":"Lipowsky Baby-LIN-RM-III LIN Bus Adapter Getting Started Guide"}],"download_filetype":[{"download_filetype":"pdf"}]}] - condition: new - custom_product: false - mpn: BABY-LIN-RM-III - google_product_category: Electronics - custom_label_0: PC Adapter - myordercount: {"ordercount":2,"recentcount":2} - warranty: 12 months - brand: Lipowsky - key_feature_1: LIN and CAN-Bus simulator with digital I/O interface - manufacturer: Lipowsky Industrie Elektronik GmbH - badge: - widget:

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
- brands: gid://shopify/Metaobject/56255217887 - breadcrumbs: ["gid://shopify/Collection/267180835005"] - key_feature_2: Supports LIN bus versions 1.2, 1.3, 2.0, 2.1 and 2.2, as well as CAN-FD, CAN-High-Speed and CAN-Low-Speed buses - key_feature_3: Provides 8 input and 6 output 24V signals with 3 analogue inputs - key_feature_4: 2 freely programmable buttons integrated - key_feature_5: Compact module for top-hat rail mounting. 76 x 133 x 36mm (H x W x D) - key_feature_6: Galvanically isolated LIN and CAN bus interface - key_feature_7: MicroSD card up to 32 GB - key_feature_8: Windows 7/8/10/11 (32/64 Bit) - customhs_code: 903089 - detailed_description: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Baby-LIN-RM-III","bold":true},{"type":"text","value":" is a controller that can be used to control LIN or CAN interface using a standard computer. This device comes with an integrated 32-bit microcontroller that can perform all time-critical operations."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"LINWorks V2 Software"}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Baby-LIN-RM-III","bold":true},{"type":"text","value":" includes the easy-to-use LINWorks V2 software suite."}]},{"type":"paragraph","children":[{"type":"text","value":"Based on LDF or DBC files configurations can be set up within minutes. Each configuration can define which nodes from the bus will be simulated by the "},{"type":"text","value":"Baby-LIN-RM-III","bold":true},{"type":"text","value":" (restbus simulation) or how a change of state at the digital inputs will change bus signals or trigger a macro. Via the digital inputs PWM signals can be read, scaled and mapped to bus signals."}]},{"type":"paragraph","children":[{"type":"text","value":"Signal values can be read can be read and written in real-time while other operations are in progress. This can be done via a Simple Menu found in the LINWorks suite or by a custom product or even via the API functions of a supplied DLL."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Operating System Compatibility"}]},{"type":"paragraph","children":[{"type":"text","value":"The LINWorks-V2 software suite is compatible to Win-XP, Win7, Win8 and Win10 (16 and 32-bit). A Linux version is available upon request."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Digital I/O"}]},{"type":"paragraph","children":[{"type":"text","value":"Also, the module's digital outputs can be controlled by the values of the bus signals. For instance; an output can be set, if a signal is equal to, not equal to, greater or less than a reference value. It also can be tested, if a certain signal value is within a given range or not."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"LIN Bus Interface"}]},{"type":"paragraph","children":[{"type":"text","value":"The implemented LIN driver supports bus voltages up to 36 volts and can be used to up to 200 Kbit/s. These way even nodes that operate outside the standard limits of the LIN specifications can be controlled with the "},{"type":"text","value":"Baby-LIN-RM-III","bold":true},{"type":"text","value":"."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"CAN Bus Interface"}]},{"type":"paragraph","children":[{"type":"text","value":"One CAN interface is designed as a high-speed interface, conforming to ISO-11898 with a SN65HVD251 driver while the other interface utilises a fault-tolerant low-speed physical layer conforming to ISO-11519 with a TJA1054 transceiver."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Galvanically Isolated Interfaces"}]},{"type":"paragraph","children":[{"type":"text","value":"All communication interfaces (LIN, CAN and USB) as well as the digital inputs are galvanically isolated from the module's logic circuit."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Programmable Buttons"}]},{"type":"paragraph","children":[{"type":"text","value":"Additionally, the Baby-LIN-RM-II offers two programmable buttons that may be configured to control the start and stop functions of the bus."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Stand-alone Operation"}]},{"type":"paragraph","children":[{"type":"text","value":"The configuration designed on a computer can be transferred to and stored on the device, allowing you to use the controller as a standalone device, without any computer."}]},{"type":"heading","level":2,"children":[{"type":"text","value":"Applications"}]},{"type":"paragraph","children":[{"type":"text","value":"The "},{"type":"text","value":"Baby-LIN-RM-III","bold":true},{"type":"text","value":" makes is easy to add LIN or CAN bus communication capabilities to PLC-based test equipment such as durability test facilities, validation tests etc. The Baby-LIN-RM-II is equipped with a powerful 32-bit microcontroller that handles all time-critical operations such as message formatting and the decoding of the bus protocol."},{"type":"text","value":""},{"type":"text","value":"."}]}]} - summary:

The Lipowsky Baby-LIN-RM-III allows LIN-Bus, CAN-Bus and CAN-FD Bus-equipped devices to be controlled by a PC.

The interface can simulate CAN and LIN-Bus Master and Slave nodes

After installation of the supplied LINWorks software, you can connect the Baby-LIN-RM-III to a free USB port and access the LIN- and CAN-Bus devices via LINWorks or your programs Baby-LIN-DLL. In addition, LIN and CAN devices can be controlled using digital signals only. This enhances testing facilities based on a PLC (Programmable Logic Controller) by a LIN- or CAN-Bus without much effort.

This can be highly beneficial to facilities with long-term testing.