# Title: Hantek HSA2016 Spectrum Analyser (1KHz - 1.6GHz) ## Description: Features Frequency range: 9KHz-1.6GHz (tunable to 9KHz) AC Coupled Optimal sensitivity: -161dBm RBW:10Hz to 1MHz IP-51, High protection portable design, sturdy and durable, can be used in laboratory, more suitable for field mobile use. built-in large capacity lithium battery can work for more than 4 hours.18650mAh rechargeable battery. 5.6-inch highlight colour screen shows waveforms clearly in all conditions. HSA2000 Series spectrum analyzer has the lowest DANL and SSB phase noise, and the narrowest RBW. It greatly enhances the recognition ability of the spurious signal and noise signal. Optional FM/AM modulation analysis, including carrier power, modulation rate, AM depth/FM deviation, SINAD and carrier frequency offset. Standard spectrum feature. It can analyze the signal time stability, and find out lacunar signals in the communication system accurately. Strong field strength test function, fit for the test work in transmitter, base station and the antenna coverage site. It can show the density of field strength or power. The user could also calibrate gain or loss by using the amplitude offset function. HAS2000 Series has the least RBW in the same level of analyzers, and can easily confirm, distinguish and measure two similar signals. The 5.7-inch highlight colour display can provide accurate, bright and clear traces both inside and outside, no need to move into the shade to work. Short scanning time. It can fast catch the data and help to locate and recognize the irregular transient disturbance signal and then optimize the testing time and accuracy. Firm and tight mechanical structure, close rubber sleeve pack, ideal for harsh work environments. Integration USB Host & Device, support USB flash disk memory, optional WIFI/LAN, which is convenient for networking and long-range control. Its PC software can achieve the management and storage of testing data. KIT I Accessory bag N-SMA adapter N-BNC adapter BNC-BNC cable 315MHz antenna 433MHz antenna 900M/1.8GHz antenna 2.4GHz antenna KIT II Accessory bag N-SMA adapter N-BNC adapter BNC-BNC cable 315MHz antenna 433MHz antenna 900M/1.8GHz antenna 2.4GHz antenna 50Ω - 75Ω impedance converter N-SMA cable Parameters Model HSA2016A HSA2016B Frequency Frequency Range 9KHz~1.6GHz AC Coupled 9KHz~1.6GHz AC Coupled 5M~1.6GHz TG Frequency Resolution 1Hz Reference Frequency 10MHz Frequency Readout Accuracy ±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+marker resolution+1Hz) Internal 10MHz Reference Accuracy Ageing rate ±1ppm/year(0℃~50℃, Reference is 25℃) Temperature stability ±1ppm/year Marker Resolution (Frequency span)/(number of sweep points-1) Resolution Bandwidth(RBW) -3dB Bandwidth 10Hz to 1MHz,1-3-10 sequence Accuracy ±5% RBW=10Hz~1MHz nominal Resolution Filter Shape Factor <5:1 nominal Video Bandwidth(VBW) -3dB bandwidth 1Hz to 1MHz,1-3-10 sequence Accuracy ±10% VBM=1Hz~1MHz nominal Displayed Average Noise Level (normalized to1Hz) 9K~1MHz Preamp off -108dBm,typical -127dBm 1MHz ~10MHz -128dBm,typical -146dBm 10MHz ~500MHz -142dBm,typical -146dBm 500MHz ~2.5GHz -141dBm,typical -145dBm 2.5GHz ~3GHz -140dBm,typical -144dBm 9K~1MHz Preamp on -131dBm,typical -150dBm 1MHz ~10MHz -148dBm,typical -163dBm 10MHz ~500MHz -161dBm,typical -164dBm 500MHz ~2.5GHz -159dBm,typical -162dBm 2.5GHz ~3GHz -158dBm,typical -161dBm SSB Phase Noise Carrier Offset(20℃~ 30℃,500MHz Central Frequency) 10K < -92 dBc/Hz, typical -95 dBc/Hz 30K < -93 dBc/Hz, typical -96 dBc/Hz 100K < -95 dBc/Hz, typical -97 dBc/Hz 1MHz < -117 dBc/Hz, typical -119 dBc/Hz Sweep Time Range Span >100Hz 2ms to 1000s Span=0Hz 600ns to 200s Sweep Mode Continuous, single Trigger Source Free run; video; external Trigger slope Selectable positive or negative edge Trigger delay Span =0Hz ±12ms to ±12s nominal Frequency Counter Counter Resolution 1Hz Accuracy ± (marker frequency × frequency reference uncertainty + counter resolution) Level Display Range Log Scale and Units 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed Linear Scale and Units 0 to 100%,10 divisions displayed Scale Unit dBm,dBmV,dBuV,Watts,Volts Sweep (Trace) Points 461 Number of Markers 4 Detectors Normal, positive peak, sample, negative peak, RMS Number of Traces 4 Trace Functions Clear/write, maximum hold, minimum hold, average, check, close Level Measurement Error ±1.5dB(excluding input VSWR mismatch) 20~30℃, peak detector, preamplifier off, input signal -50dBm to 0dBm Reference Level Setting Range -100dBm to +30dBm, steps of 1dB Setting Resolution Log scale 0.01dB Linear scale Almost log(2.236μV to 7.07V) Amplitude Maximum Safety Input Level Average continuous power +33dBm DC input voltage 50Vdc Measurement Range 9KHz~2MHz Displayed average noise level (DANL) to +10dB 2MHz~3GHz Displayed average noise level (DANL) to +20dB Input attenuator range 0 to 51dB,1dB steps Spurious Response Second Harmonic Distortion(SHI) <65dBc,50MHz to 3GHz(Mixer level -30dBm,attenuator =0dB,preamp off,20℃~30℃) Third-Order Intermodulation(TOI) 50~300MHz +3dBm,Third-order intermodulation products:2 x -20dBm; frequency separation 100KHz:attenuation = 0dB; preamp off,20℃~30℃ 300MHz~1.6GHz +3dBm Input Related Spurious <-75dBc,(input mixer = -30dBm) Inherent Residual Response <-90dBm,typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off) RF Input VSWR (at Tuned Frequency) 10MHz to 1.6GHz <1.5:1, nominal Attenuator setting 10~20dB 10MHz Reference/External Trigger Input Reference Input Frequency 10MHz Reference Input Amplitude 0~10dBm Trigger Voltage 5V TTL level Connector and Output Impendence N female;(50Ω) General Feature Interface Language English, Chinese, Chinese Traditional Display Index 5.7 inch,640*480 resolution,64M colour LCD display Temperature Range Working -10℃ to +50℃,(battery:0℃ to 50℃) Storage -40℃ to +70℃,(battery:-20℃ to 50℃) Relative Humidity <95% Weight 2.9kg(with battery),2.6kg(without battery) Size 260m X 220m X 75m Power Input voltage range DC: 12-17V, maximum 2.8A input 220VAC±15% AC frequency range 40Hz to 60Hz Power consumption Maximum 32W ## Product type: Spectrum Analyser ## Vendor: Hantek Electronic Co Ltd ## Tags: Hantek, Spectrum Analyser ## Price range: 1250.0 - 1565.0 GBP ## Link: https://thedebugstore.com/products/hantek-hsa2016-spectrum-analyser-uk ## Options - Output: Tracking, No Tracking - Accessory Kit: Kit I, Kit II ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Hantek Electronic Co. Ltd](https://thedebugstore.com/a/llms/collections/hantek-electronic-catalogue) - [Spectrum Analysers](https://thedebugstore.com/a/llms/collections/spectrum-analysers-catalogue-uk) - [Admin: No Inventory](https://thedebugstore.com/a/llms/collections/no-inventory) - [Hantek Spectrum Analysers](https://thedebugstore.com/a/llms/collections/hantek-spectrum-analysers) ## Variants - Tracking / Kit I, SKU: HSA2016A-KITI, Available: yes, Inventory: 0 - Tracking / Kit II, SKU: HSA2016A-KITII, Available: yes, Inventory: 0 - No Tracking / Kit I, SKU: HSA2016B-KITI, Available: yes, Inventory: 0 - No Tracking / Kit II, SKU: HSA2016B-KITII, Available: yes, Inventory: 0 ## Metafields - title_tag: Hantek HSA2016 (Hantek HDS2016) Handheld Spectrum Analyser - Portable RF Testing | The Debug Store - manufacturer: Hantek Electronic Co Ltd - backorder_label: If no stock is shown above, order now and we'll ship within 10 working days. - full_description:
KIT I
KIT II
|
Parameters |
|||
|
Model |
HSA2016A |
HSA2016B |
|
|
Frequency |
|||
|
Frequency Range |
9KHz~1.6GHz AC Coupled |
9KHz~1.6GHz AC Coupled 5M~1.6GHz TG |
|
|
Frequency Resolution |
1Hz |
||
|
Reference Frequency |
10MHz |
||
|
Frequency Readout Accuracy |
±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+marker resolution+1Hz) |
||
|
Internal 10MHz Reference Accuracy |
Ageing rate |
±1ppm/year(0℃~50℃, Reference is 25℃) |
|
|
Temperature stability |
±1ppm/year |
||
|
Marker Resolution |
(Frequency span)/(number of sweep points-1) |
||
|
Resolution Bandwidth(RBW) |
|||
|
-3dB Bandwidth |
10Hz to 1MHz,1-3-10 sequence |
||
|
Accuracy |
±5% RBW=10Hz~1MHz nominal |
||
|
Resolution Filter Shape Factor |
<5:1 nominal |
||
|
Video Bandwidth(VBW) |
-3dB bandwidth |
1Hz to 1MHz,1-3-10 sequence |
|
|
Accuracy |
±10% VBM=1Hz~1MHz nominal |
||
|
Displayed Average Noise Level (normalized to1Hz) |
|||
|
9K~1MHz |
Preamp off |
-108dBm,typical -127dBm |
|
|
1MHz ~10MHz |
-128dBm,typical -146dBm |
||
|
10MHz ~500MHz |
-142dBm,typical -146dBm |
||
|
500MHz ~2.5GHz |
-141dBm,typical -145dBm |
||
|
2.5GHz ~3GHz |
-140dBm,typical -144dBm |
||
|
9K~1MHz |
Preamp on |
-131dBm,typical -150dBm |
|
|
1MHz ~10MHz |
-148dBm,typical -163dBm |
||
|
10MHz ~500MHz |
-161dBm,typical -164dBm |
||
|
500MHz ~2.5GHz |
-159dBm,typical -162dBm |
||
|
2.5GHz ~3GHz |
-158dBm,typical -161dBm |
||
|
SSB Phase Noise |
|||
|
Carrier Offset(20℃~ 30℃,500MHz Central Frequency) |
10K |
< -92 dBc/Hz, typical -95 dBc/Hz |
|
|
30K |
< -93 dBc/Hz, typical -96 dBc/Hz |
||
|
100K |
< -95 dBc/Hz, typical -97 dBc/Hz |
||
|
1MHz |
< -117 dBc/Hz, typical -119 dBc/Hz |
||
|
Sweep Time |
|||
|
Range |
Span >100Hz |
2ms to 1000s |
|
|
Span=0Hz |
600ns to 200s |
||
|
Sweep Mode |
Continuous, single |
||
|
Trigger Source |
Free run; video; external |
||
|
Trigger slope |
Selectable positive or negative edge |
||
|
Trigger delay |
Span =0Hz |
±12ms to ±12s nominal |
|
|
Frequency Counter |
|||
|
Counter Resolution |
1Hz |
||
|
Accuracy |
± (marker frequency × frequency reference uncertainty + counter resolution) |
||
|
Level Display Range |
|||
|
Log Scale and Units |
1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed |
||
|
Linear Scale and Units |
0 to 100%,10 divisions displayed |
||
|
Scale Unit |
dBm,dBmV,dBuV,Watts,Volts |
||
|
Sweep (Trace) Points |
461 |
||
|
Number of Markers |
4 |
||
|
Detectors |
Normal, positive peak, sample, negative peak, RMS |
||
|
Number of Traces |
4 |
||
|
Trace Functions |
Clear/write, maximum hold, minimum hold, average, check, close |
||
|
Level Measurement Error |
±1.5dB(excluding input VSWR mismatch) 20~30℃, peak detector, preamplifier off, input signal -50dBm to 0dBm |
||
|
Reference Level |
|||
|
Setting Range |
-100dBm to +30dBm, steps of 1dB |
||
|
Setting Resolution |
Log scale |
0.01dB |
|
|
Linear scale |
Almost log(2.236μV to 7.07V) |
||
|
Amplitude |
|||
|
Maximum Safety Input Level |
Average continuous power |
+33dBm |
|
|
DC input voltage |
50Vdc |
||
|
Measurement Range |
9KHz~2MHz |
Displayed average noise level (DANL) to +10dB |
|
|
2MHz~3GHz |
Displayed average noise level (DANL) to +20dB |
||
|
Input attenuator range |
0 to 51dB,1dB steps |
||
|
Spurious Response |
|||
|
Second Harmonic Distortion(SHI) |
<65dBc,50MHz to 3GHz(Mixer level -30dBm,attenuator =0dB,preamp off,20℃~30℃) |
||
|
Third-Order Intermodulation(TOI) |
50~300MHz |
+3dBm,Third-order intermodulation products:2 x -20dBm; frequency separation 100KHz:attenuation = 0dB; preamp off,20℃~30℃ |
|
|
300MHz~1.6GHz |
+3dBm |
||
|
Input Related Spurious |
<-75dBc,(input mixer = -30dBm) |
||
|
Inherent Residual Response |
<-90dBm,typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off) |
||
|
RF Input VSWR (at Tuned Frequency) |
10MHz to 1.6GHz |
<1.5:1, nominal Attenuator setting 10~20dB |
|
|
10MHz Reference/External Trigger Input |
|||
|
Reference Input Frequency |
10MHz |
||
|
Reference Input Amplitude |
0~10dBm |
||
|
Trigger Voltage |
5V TTL level |
||
|
Connector and Output Impendence |
N female;(50Ω) |
||
|
General Feature |
|||
|
Interface Language |
English, Chinese, Chinese Traditional |
||
|
Display Index |
5.7 inch,640*480 resolution,64M colour LCD display |
||
|
Temperature Range |
Working |
-10℃ to +50℃,(battery:0℃ to 50℃) |
|
|
Storage |
-40℃ to +70℃,(battery:-20℃ to 50℃) |
||
|
Relative Humidity |
<95% |
||
|
Weight |
2.9kg(with battery),2.6kg(without battery) |
||
|
Size |
260m X 220m X 75m |
||
|
Power |
Input voltage range |
DC: 12-17V, maximum 2.8A input 220VAC±15% |
|
|
AC frequency range |
40Hz to 60Hz |
||
|
Power consumption |
Maximum 32W |
||
The Hantek HSA2016 handheld spectrum analyser is a compact yet powerful tool for professional RF engineers requiring portable and precise spectrum analysis. With a 9 kHz to 1.6 GHz frequency range, this device offers exceptional performance for field testing and laboratory use.
Equipped with a 5.6" display boasting a 640 x 480 resolution, the HSA2016 provides clear data visualisation for accurate signal analysis. Its built-in preamplifier ensures high sensitivity, while the RBW range of 1 Hz to 1 MHz allows for detailed signal examination.
This versatile instrument includes essential measurement functions such as channel power, occupied bandwidth, and field strength. With its rechargeable lithium battery, the HSA2016 offers up to 4 hours of continuous operation, making it ideal for on-site testing. The device also supports remote control via LAN and USB interfaces, enhancing flexibility in various testing environments.