# Title: Hantek-1833C 100 kHz Handheld LCR Meter ## Description: Specifications Model Hantek-1832C Hantek-1833C Test frequency 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz Accuracy 0.30% Equivalent Circuit Series, Parallel Test level 0.6Vrms 0.6Vrms, 0.3Vrms Measurement way Manual, Auto Display screen 2.8 inch TFT LCD Measurement parameters Principle parameter: L/C/R/Z Secondary parameter: X/D/Q/θ/ESR Principle parameter L/C/R/Z Deputy parameter X/D/Q/θ/ESR Inductance Measurement range (L) 0-2000H Capacitance Measurement range (C) 0-20mF Resistance Measurement range (R) 0-20MΩ Measurement Rate High spee d(4 times/s), Intermediate speed(twice/s) and Low speed(once/s) Reset Function open circuit calibration, short-circuit calibration Test Terminal Configuration 3 terminal, 5 terminal Capacitance, C and Dissipation Factor, D 100Hz/120Hz/400Hz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 20mF 4.000mF~20.000mF 8.00%+5 digits 0.08 series 4mF 400.0μF~3.9999mF 2.00%+3 digits 0.02 series 400μF 40.00μF~399.99μF 0.60%+2 digits 0.006 series 40μF 4.000μF~39.999μF 0.40%+2 digits 0.004 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ---- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.5%+3 digits 0.005 parallel 4nF 0pF~3.999nF 1.5%+5 digits ------ parallel 1KHz/4KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 1000uF 400.0uF~999.9uF 3.00%+5 digits 0.03 series 400μF 40.00μF~399.99μF 1.50%+3 digits 0.015 series 40μF 4.000μF~39.999μF 0.60%+2 digits 0.006 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ----- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.6%+3 digits 0.006 parallel 4nF 400.0pF~3.9999nF 0.6%+3 digits 0.006 parallel 400pF 0.0pF~399.9pF 3%+5 digits ------ parallel 10KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 4.00%+5 digits 0.04 series 40μF 4.000μF~39.999μF 2.0%+3 digits 0.02 series 4μF 400.0nF~3.9999μF 0.60%+2 digits 0.006 series 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 series 40nF 4.000nF~39.999nF 0.4%+2 digits 0.004 ------ 4nF 400.0pF~3.9999nF 0.4%+2 digits 0.004 parallel 400pF 40.00pF~399.99pF 0.6%+3 digits 0.006 parallel 40pF 0.00pF~39.99pF 2.5%+5 digits ------ parallel 40KHz/50KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 6.00%+5 digits 0.06 series 40μF 4.000μF~39.999μF 4.0%+3 digits 0.04 series 4μF 400.0nF~3.9999μF 1.0%+2 digits 0.01 series 400nF 40.00nF~399.99nF 0.6%+2 digits 0.006 series 40nF 4.000nF~39.999nF 0.6%+2 digits 0.006 ------ 4nF 400.0pF~3.9999nF 0.6%+2 digits 0.006 parallel 400pF 40.00pF~399.99pF 1%+3 digits 0.01 parallel 40pF 0.000pF~39.999pF 3%+5 digits ------ parallel 75KHz/100KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 10μF 4.000μF~10.000μF 8.0%+20 digits 0.08 series 4μF 400.0nF~3.9999μF 5.0%+10 digits 0.05 series 400nF 40.00nF~399.99nF 1.5%+5 digits 0.015 series 40nF 4.000nF~39.999nF 1%+2 digits 0.01 series 4nF 400.0pF~3.999nF 1%+2 digits 0.01 ------ 400pF 40.00pF~399.99pF 1.5%+2 digits 0.015 parallel 40pF 4.000pF~39.999pF 2%+5 digits 0.02 parallel 4pF 0.000pF~3.999pF 5%+10 digits ------ parallel Inductance, L and Quality Factor, Q 100Hz/120Hz/400Hz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1000H 400.0H~999.9H 2.00%+3 digits 0.02 parallel 400H 40.000H~399.99H 0.60%+2 digits 0.006 parallel 40H 4.000H~39.999H 0.40%+2 digits 0.004 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 ---- 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 series 40mH 4.000mH~39.999mH 0.6%+3 digits 0.006 series 4mH 0uH~3.999mH 3.0%+5 digits ------ series 1kHz/4KHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 1.50%+3 digits 0.015 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 parallel 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 ------ 4mH 400.0uH~3.9999mH 0.4%+2 digits 0.004 series 400uH 40.00uH~399.99uH 0.8%+3 digits 0.008 series 40uH 0.00uH~39.99uH 3.0%+5 digits ------ series 10KHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 100H 40.00H~100.00H 2.0%+3 digits 0.02 parallel 40H 4.000H~39.999H 0.60%+2 digits 0.006 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 ------ 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 series 4mH 400.0uH~3.9999mH 1%+3 digits 0.01 series 400uH 0.0uH~399.9uH 3.0%+5 digits ------ series 40kHz/50kHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 2.0%+4 digits 0.02 parallel 400mH 40.00mH~399.99mH 0.8%+2 digits 0.008 parallel 40mH 4.000mH~39.999mH 0.8%+2 digits 0.008 ------ 4mH 400.0uH~3.9999mH 0.8%+2 digits 0.008 series 400uH 40.00uH~399.99uH 1.5%+3 digits 0.015 series 40uH 0.000uH~39.999uH 4.0%+5 digits ------ series 75KHz/100KHz Range Display range Accuracy Le Accuracy De Recommended equivalent mode 100mH 40.00mH~399.99mH 2.5%+2 digits 0.025 parallel 40mH 4.000mH~39.999mH 1.5%+2 digits 0.015 parallel 4mH 400.0uH~3.9999mH 1.0%+2 digits 0.01 ------ 400uH 40.00uH~399.99uH 1.0%+2 digits 0.01 series 40uH 4.000uH~39.999uH 1.5%+5 digits 0.015 series 4uH 0.000uH~3.999uH 4%+10 digits ------ series Impedance, Z and Phase Angle, θ 100Hz/120Hz/400Hz/1KHz/10KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 3.0%+10 digits 3.4° parallel 4MΩ 400.0kΩ~3.9999MΩ 1.2%+3 digits 0.7° parallel 400kΩ 40.00kΩ~399.99kΩ 0.3%+3 digits 0.2° parallel 40kΩ 4.000kΩ~39.999kΩ 0.25%+2 digits 0.1° ------ 4kΩ 400.0Ω~3.9999kΩ 0.25%+2 digits 0.1° series 400Ω 40.00Ω~399.99Ω 0.25%+2 digits 0.1° series 40Ω 4.000Ω~39.999Ω 0.5%+3 digits 0.3° series 4Ω 0.4000Ω~3.9999Ω 2.0%+3 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 4.0%+3 digits ------ series 40KHz/50KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 7.0%+41 digits 4.0° parallel 4MΩ 400.0kΩ~3.9999MΩ 2.5%+3 digits 1.4° parallel 400kΩ 40.00kΩ~399.99kΩ 1.0%+4 digits 0.6° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+4 digits 0.6° ------ 4kΩ 400.0Ω~3.9999kΩ 0.5%+3 digits 0.3° series 400Ω 40.00Ω~399.99Ω 0.5%+3 digits 0.3° series 40Ω 4.000Ω~39.999Ω 0.7%+4 digits 0.4° series 4Ω 0.4000Ω~3.9999Ω 2.0%+6 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 5.0%+10 digits ------ series 75KHz/100KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 9.0%+20 digits 5.2° parallel 4MΩ 400.0kΩ~3.9999MΩ 4.0%+10 digits 2.3° parallel 400kΩ 40.00kΩ~399.99kΩ 1.5%+4 digits 0.9° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+2 digits 0.6° parallel 4kΩ 400.0Ω~3.9999kΩ 0.7%+2 digits 0.4° ------ 400Ω 40.00Ω~399.99Ω 0.7%+2 digits 0.4° series 40Ω 4.000Ω~39.999Ω 1.0%+5 digits 0.6° series 4Ω 0.4000Ω~3.9999Ω 3.0%+10 digits 1.7° series 0.4Ω 0.0000Ω~0.3999Ω 7%+20 digits ------ series ## Product type: Meter ## Vendor: Hantek Electronic Co Ltd ## Tags: Capacitance, Device, Handheld Oscilloscope, Hantek, hantek-electronic-co-ltd, hantekInductance, Inductance, LCR, Meter, Resistance ## Price range: 190.0 - 190.0 GBP ## Link: https://thedebugstore.com/products/hantek-1833c-100khz-handheld-lcr-meter-1833c ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Hantek Electronic Co. Ltd](https://thedebugstore.com/a/llms/collections/hantek-electronic-catalogue) - [Admin: No Inventory](https://thedebugstore.com/a/llms/collections/no-inventory) - [Test Meters](https://thedebugstore.com/a/llms/collections/test-meters-catalogue) - [Test & Measurement](https://thedebugstore.com/a/llms/collections/test-measurement-catalogue) - [LCR Meters](https://thedebugstore.com/a/llms/collections/lcr-meters-catalogue) - [Resistance Meters](https://thedebugstore.com/a/llms/collections/resistance-meter-catalogue) - [Hantek Handheld Oscilloscope](https://thedebugstore.com/a/llms/collections/hantek-handheld-oscilloscopes) - [Hantek LCR Meters](https://thedebugstore.com/a/llms/collections/hantek-lcr-meters-catalogue) - [Capacitance Meters](https://thedebugstore.com/a/llms/collections/capacitance-meters-catalogue) - [Inductance Meters](https://thedebugstore.com/a/llms/collections/inductance-meters-catalogue) ## Variants - Default Title, SKU: Hantek-1833C, Available: yes, Inventory: 0 ## Metafields - full_description:

Specifications

Model Hantek-1832C Hantek-1833C
Test frequency

100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz

100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz

Accuracy 0.30%
Equivalent Circuit Series, Parallel
Test level 0.6Vrms 0.6Vrms, 0.3Vrms
Measurement way Manual, Auto
Display screen 2.8 inch TFT LCD
Measurement parameters Principle parameter: L/C/R/Z   Secondary parameter: X/D/Q/θ/ESR
Principle parameter L/C/R/Z
Deputy parameter X/D/Q/θ/ESR
Inductance Measurement range (L) 0-2000H
Capacitance Measurement range (C) 0-20mF
Resistance  Measurement range (R) 0-20MΩ
Measurement Rate High spee d(4 times/s), Intermediate speed(twice/s) and Low speed(once/s)
Reset Function open circuit calibration, short-circuit calibration
Test Terminal Configuration 3 terminal, 5 terminal

Capacitance, C and Dissipation Factor, D

100Hz/120Hz/400Hz

Range Display range Accuracy Ce  Accuracy De  Recommended equivalent mode
20mF  4.000mF~20.000mF  8.00%+5 digits 0.08 series
4mF  400.0μF~3.9999mF  2.00%+3 digits 0.02 series
400μF  40.00μF~399.99μF  0.60%+2 digits  0.006 series
40μF  4.000μF~39.999μF  0.40%+2 digits 0.004 series
4μF  400.0nF~3.9999μF  0.40%+2 digits 0.004 ---- 
400nF  40.00nF~399.99nF  0.4%+2 digits 0.004 parallel
40nF  4.000nF~39.999nF  0.5%+3 digits 0.005 parallel
4nF  0pF~3.999nF  1.5%+5 digits  ------  parallel

1KHz/4KHz

Range Display range Accuracy Ce  Accuracy De  Recommended equivalent mode
1000uF  400.0uF~999.9uF  3.00%+5 digits 0.03 series
400μF  40.00μF~399.99μF  1.50%+3 digits 0.015 series
40μF  4.000μF~39.999μF  0.60%+2 digits  0.006 series
4μF  400.0nF~3.9999μF  0.40%+2 digits 0.004 -----
400nF  40.00nF~399.99nF  0.4%+2 digits 0.004 parallel
40nF  4.000nF~39.999nF  0.6%+3 digits 0.006 parallel
4nF  400.0pF~3.9999nF  0.6%+3 digits 0.006 parallel
400pF 0.0pF~399.9pF 3%+5 digits ------ parallel

10KHz

Range Display range Accuracy Ce  Accuracy De  Recommended equivalent mode
100μF  40.00μF~100.00μF  4.00%+5 digits  0.04 series
40μF  4.000μF~39.999μF  2.0%+3 digits 0.02 series
4μF  400.0nF~3.9999μF  0.60%+2 digits 0.006 series
400nF  40.00nF~399.99nF  0.4%+2 digits 0.004 series
40nF  4.000nF~39.999nF  0.4%+2 digits 0.004 ------ 
4nF  400.0pF~3.9999nF  0.4%+2 digits 0.004 parallel
400pF 40.00pF~399.99pF 0.6%+3 digits 0.006 parallel
40pF 0.00pF~39.99pF 2.5%+5 digits ------  parallel

40KHz/50KHz

Range Display range Accuracy Ce  Accuracy De  Recommended equivalent mode
100μF  40.00μF~100.00μF  6.00%+5 digits 0.06 series
40μF  4.000μF~39.999μF  4.0%+3 digits  0.04 series
4μF  400.0nF~3.9999μF  1.0%+2 digits  0.01 series
400nF  40.00nF~399.99nF  0.6%+2 digits 0.006 series
40nF  4.000nF~39.999nF  0.6%+2 digits  0.006 ------ 
4nF  400.0pF~3.9999nF  0.6%+2 digits  0.006 parallel
400pF 40.00pF~399.99pF 1%+3 digits 0.01 parallel
40pF 0.000pF~39.999pF 3%+5 digits ------  parallel

75KHz/100KHz

Range Display range Accuracy Ce  Accuracy De  Recommended equivalent mode
10μF  4.000μF~10.000μF  8.0%+20 digits 0.08 series
4μF  400.0nF~3.9999μF  5.0%+10 digits  0.05 series
400nF  40.00nF~399.99nF  1.5%+5 digits 0.015 series
40nF  4.000nF~39.999nF  1%+2 digits 0.01 series
4nF  400.0pF~3.999nF  1%+2 digits 0.01 ------  
400pF 40.00pF~399.99pF 1.5%+2 digits 0.015 parallel
40pF 4.000pF~39.999pF 2%+5 digits 0.02 parallel
4pF 0.000pF~3.999pF 5%+10 digits ------  parallel

Inductance, L and Quality Factor, Q

100Hz/120Hz/400Hz

Range Display range Accuracy Le  Accuracy De* Recommended equivalent mode
1000H  400.0H~999.9H  2.00%+3 digits 0.02 parallel
400H  40.000H~399.99H  0.60%+2 digits 0.006 parallel
40H  4.000H~39.999H  0.40%+2 digits 0.004 parallel
4H  400.0mH~3.9999H  0.40%+2 digits  0.004 ---- 
400mH  40.00mH~399.99mH  0.4%+2 digits 0.004 series
40mH  4.000mH~39.999mH  0.6%+3 digits 0.006 series
4mH  0uH~3.999mH  3.0%+5 digits ------  series

1kHz/4KHz

Range Display range Accuracy Le  Accuracy De* Recommended equivalent mode
1H  400.0mH~999.9mH  1.50%+3 digits 0.015 parallel
400mH  40.00mH~399.99mH  0.4%+2 digits 0.004 parallel
40mH  4.000mH~39.999mH  0.4%+2 digits 0.004 ------ 
4mH  400.0uH~3.9999mH  0.4%+2 digits 0.004 series
400uH 40.00uH~399.99uH 0.8%+3 digits 0.008 series
40uH 0.00uH~39.99uH 3.0%+5 digits ------ series

10KHz

Range Display range Accuracy Le  Accuracy De* Recommended equivalent mode
100H  40.00H~100.00H  2.0%+3 digits  0.02 parallel
40H  4.000H~39.999H  0.60%+2 digits 0.006 parallel
4H  400.0mH~3.9999H  0.40%+2 digits  0.004 parallel
400mH  40.00mH~399.99mH  0.4%+2 digits 0.004 ------ 
40mH  4.000mH~39.999mH  0.4%+2 digits 0.004 series
4mH  400.0uH~3.9999mH  1%+3 digits 0.01 series
400uH 0.0uH~399.9uH 3.0%+5 digits ------ series

40kHz/50kHz

Range Display range Accuracy Le  Accuracy De* Recommended equivalent mode
1H  400.0mH~999.9mH  2.0%+4 digits 0.02 parallel
400mH  40.00mH~399.99mH  0.8%+2 digits 0.008 parallel
40mH  4.000mH~39.999mH  0.8%+2 digits 0.008 ------ 
4mH  400.0uH~3.9999mH  0.8%+2 digits 0.008 series
400uH 40.00uH~399.99uH 1.5%+3 digits 0.015 series
40uH 0.000uH~39.999uH 4.0%+5 digits ------ series

75KHz/100KHz

Range Display range Accuracy Le  Accuracy De Recommended equivalent mode
100mH  40.00mH~399.99mH  2.5%+2 digits 0.025 parallel
40mH  4.000mH~39.999mH  1.5%+2 digits 0.015 parallel
4mH  400.0uH~3.9999mH  1.0%+2 digits 0.01 ------ 
400uH 40.00uH~399.99uH 1.0%+2 digits 0.01 series
40uH 4.000uH~39.999uH 1.5%+5 digits 0.015 series
4uH 0.000uH~3.999uH 4%+10 digits ------ series

 Impedance,  Z and Phase Angle, θ

100Hz/120Hz/400Hz/1KHz/10KHz

Range Display range Accuracy Ze Accuracy Recommended equivalent mode
20MΩ 4.000MΩ~20.000MΩ 3.0%+10 digits 3.4° parallel
4MΩ 400.0kΩ~3.9999MΩ 1.2%+3 digits 0.7° parallel
400kΩ 40.00kΩ~399.99kΩ 0.3%+3 digits 0.2° parallel
40kΩ 4.000kΩ~39.999kΩ 0.25%+2 digits 0.1° ------
4kΩ 400.0Ω~3.9999kΩ 0.25%+2 digits 0.1° series
400Ω 40.00Ω~399.99Ω 0.25%+2 digits 0.1° series
40Ω 4.000Ω~39.999Ω 0.5%+3 digits 0.3° series
0.4000Ω~3.9999Ω 2.0%+3 digits 1.1° series
0.4Ω 0.0000Ω~0.3999Ω 4.0%+3 digits ------ series

40KHz/50KHz

Range Display range Accuracy Ze Accuracy Recommended equivalent mode
20MΩ 4.000MΩ~20.000MΩ 7.0%+41 digits 4.0° parallel
4MΩ 400.0kΩ~3.9999MΩ 2.5%+3 digits 1.4° parallel
400kΩ 40.00kΩ~399.99kΩ 1.0%+4 digits 0.6° parallel
40kΩ 4.000kΩ~39.999kΩ 1.0%+4 digits 0.6° ------
4kΩ 400.0Ω~3.9999kΩ 0.5%+3 digits 0.3° series
400Ω 40.00Ω~399.99Ω 0.5%+3 digits 0.3° series
40Ω 4.000Ω~39.999Ω 0.7%+4 digits 0.4° series
0.4000Ω~3.9999Ω 2.0%+6 digits 1.1° series
0.4Ω 0.0000Ω~0.3999Ω 5.0%+10 digits ------ series

75KHz/100KHz

Range Display range Accuracy Ze Accuracy Recommended equivalent mode
20MΩ 4.000MΩ~20.000MΩ 9.0%+20 digits 5.2° parallel
4MΩ 400.0kΩ~3.9999MΩ 4.0%+10 digits 2.3° parallel
400kΩ 40.00kΩ~399.99kΩ 1.5%+4 digits 0.9° parallel
40kΩ 4.000kΩ~39.999kΩ 1.0%+2 digits 0.6° parallel
4kΩ 400.0Ω~3.9999kΩ 0.7%+2 digits 0.4° ------
400Ω 40.00Ω~399.99Ω 0.7%+2 digits 0.4° series
40Ω 4.000Ω~39.999Ω 1.0%+5 digits 0.6° series
0.4000Ω~3.9999Ω 3.0%+10 digits 1.7° series
0.4Ω 0.0000Ω~0.3999Ω 7%+20 digits ------ series
- description_tag: Hantek-1833C handheld LCR meter—10 test frequencies to 100 kHz, ESR/D/Q/θ, 3/5-terminal guard, USB software. Measure components accurately. Order today at Debug Store. - title_tag: Hantek-1833C 100 kHz Handheld LCR Meter | Debug Store UK - manufacturer: Hantek Electronic Co Ltd - warranty: 12 months - amazon_enable: TRUE - amazon_title: Hantek-1833C Handheld LCR Meter to 100KHz - amazon_product_type: computercomponent - amazon_block: FALSE - amazon_prime_enable: TRUE - amazon_search: Hantek - amazon_uk_price: 192.5 - amazon_uk_currency: GBP - amazon_de_currency: EUR - amazon_de_price: 217.525 - amazon_fr_currency: EUR - amazon_fr_price: 217.525 - amazon_es_currency: EUR - amazon_es_price: 217.525 - amazon_nl_currency: EUR - amazon_nl_price: 217.525 - amazon_it_currency: EUR - amazon_it_price: 217.525 - amazon_se_curency: SEK - amazon_se_price: 2194.5 - amazon_product_id: 5055383617128 - amazon_product_id_type: EAN - amazon_update: Update - amazon_short_description: The Hantek-1833C is a professional handheld LCR Meter. Designed for use in the lab, it is designed to accurately measure component characteristics and can be relied upon.The instrument will measure basic values such as Resistance, Capacitance and Inductance and Impedance at different test frequencies. This also allows the measurement of frequency-related characteristics such as ESR and Q.The instrument can also log values over time which allows the measurement of value drift over changes in external temperature etc. - amazon_long_description:

Specifications

ModelHantek-1832CHantek-1833C
Test frequency

100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz,

40kHz

100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 

40kHz, 50kHz, 75kHz, 100kHz

Accuracy0.30%
Equivalent Circuitseries, parallel
Test level0.6Vrms0.6Vrms, 0.3Vrms
Measurement waymanual, auto
Display screen2.8 inch TFT LCD
Measurement parametersprinciple parameter: L/C/R/Z   deputy parameter: X/D/Q/θ/ESR
Principle parameterL/C/R/Z
Deputy parameterX/D/Q/θ/ESR
Inductance Measurement range(L) 0-2000H
Capacitance Measurement range(C) 0-20mF
Resistance  Measurement range(R) 0-20MΩ
Measurement speedhigh speed(4 times/s)intermediate speed(twice/s)low speed(once/s)
Reset functionopen circuit calibration, short-circuit calibration
Test terminal configuration3 terminal, 5 terminal
Includesstandard with 1.USB Type-C data cable; 2.power adapter; 3.short circuit card; 4.red and black rubber plug; 5.large capacity lithium battery

Capacitance C and dissipation - D

100Hz/120Hz/400Hz

RangeDisplay rangeAccuracy Ce Accuracy De Recommended equivalent mode
20mF 4.000mF~20.000mF 8.00%+5 digits0.08series
4mF 400.0μF~3.9999mF 2.00%+3 digits0.02series
400μF 40.00μF~399.99μF 0.60%+2 digits 0.006series
40μF 4.000μF~39.999μF 0.40%+2 digits0.004series
4μF 400.0nF~3.9999μF 0.40%+2 digits0.004---- 
400nF 40.00nF~399.99nF 0.4%+2 digits0.004parallel
40nF 4.000nF~39.999nF 0.5%+3 digits0.005parallel
4nF 0pF~3.999nF 1.5%+5 digits ------ parallel

1KHz/4kHz

RangeDisplay rangeAccuracy Ce Accuracy De Recommended equivalent mode
1000uF 400.0uF~999.9uF 3.00%+5 digits0.03series
400μF 40.00μF~399.99μF 1.50%+3 digits0.015series
40μF 4.000μF~39.999μF 0.60%+2 digits 0.006series
4μF 400.0nF~3.9999μF 0.40%+2 digits0.004-----
400nF 40.00nF~399.99nF 0.4%+2 digits0.004parallel
40nF 4.000nF~39.999nF 0.6%+3 digits0.006parallel
4nF 400.0pF~3.9999nF 0.6%+3 digits0.006parallel
400pF0.0pF~399.9pF3%+5 digits------parallel

10KHz

RangeDisplay rangeAccuracy Ce Accuracy De Recommended equivalent mode
100μF 40.00μF~100.00μF 4.00%+5 digits 0.04series
40μF 4.000μF~39.999μF 2.0%+3 digits0.02series
4μF 400.0nF~3.9999μF 0.60%+2 digits0.006series
400nF 40.00nF~399.99nF 0.4%+2 digits0.004series
40nF 4.000nF~39.999nF 0.4%+2 digits0.004------ 
4nF 400.0pF~3.9999nF 0.4%+2 digits0.004parallel
400pF40.00pF~399.99pF0.6%+3 digits0.006parallel
40pF0.00pF~39.99pF2.5%+5 digits------ parallel

40KHz/50KHz

RangeDisplay rangeAccuracy Ce Accuracy De Recommended equivalent mode
100μF 40.00μF~100.00μF 6.00%+5 digits0.06series
40μF 4.000μF~39.999μF 4.0%+3 digits 0.04series
4μF 400.0nF~3.9999μF 1.0%+2 digits 0.01series
400nF 40.00nF~399.99nF 0.6%+2 digits0.006series
40nF 4.000nF~39.999nF 0.6%+2 digits 0.006------ 
4nF 400.0pF~3.9999nF 0.6%+2 digits 0.006parallel
400pF40.00pF~399.99pF1%+3 digits0.01parallel
40pF0.000pF~39.999pF3%+5 digits------ parallel

75KHz/100KHz

RangeDisplay rangeAccuracy Ce Accuracy De Recommended equivalent mode
10μF 4.000μF~10.000μF 8.0%+20 digits0.08series
4μF 400.0nF~3.9999μF 5.0%+10 digits 0.05series
400nF 40.00nF~399.99nF 1.5%+5 digits0.015series
40nF 4.000nF~39.999nF 1%+2 digits0.01series
4nF 400.0pF~3.999nF 1%+2 digits0.01------  
400pF40.00pF~399.99pF1.5%+2 digits0.015parallel
40pF4.000pF~39.999pF2%+5 digits0.02parallel
4pF0.000pF~3.999pF5%+10 digits------ parallel

Inductance L and quality factor

100Hz/120Hz/400Hz

RangeDisplay rangeAccuracy Le Accuracy De*Recommended equivalent mode
1000H 400.0H~999.9H 2.00%+3 digits0.02parallel
400H 40.000H~399.99H 0.60%+2 digits0.006parallel
40H 4.000H~39.999H 0.40%+2 digits0.004parallel
4H 400.0mH~3.9999H 0.40%+2 digits 0.004---- 
400mH 40.00mH~399.99mH 0.4%+2 digits0.004series
40mH 4.000mH~39.999mH 0.6%+3 digits0.006series
4mH 0uH~3.999mH 3.0%+5 digits------ series

1kHz/4KHz

RangeDisplay rangeAccuracy Le Accuracy De*Recommended equivalent mode
1H 400.0mH~999.9mH 1.50%+3 digits0.015parallel
400mH 40.00mH~399.99mH 0.4%+2 digits0.004parallel
40mH 4.000mH~39.999mH 0.4%+2 digits0.004------ 
4mH 400.0uH~3.9999mH 0.4%+2 digits0.004series
400uH40.00uH~399.99uH0.8%+3 digits0.008series
40uH0.00uH~39.99uH3.0%+5 digits------series

10kHz

RangeDisplay rangeAccuracy Le Accuracy De*Recommended equivalent mode
100H 40.00H~100.00H 2.0%+3 digits 0.02parallel
40H 4.000H~39.999H 0.60%+2 digits0.006parallel
4H 400.0mH~3.9999H 0.40%+2 digits 0.004parallel
400mH 40.00mH~399.99mH 0.4%+2 digits0.004------ 
40mH 4.000mH~39.999mH 0.4%+2 digits0.004series
4mH 400.0uH~3.9999mH 1%+3 digits0.01series
400uH0.0uH~399.9uH3.0%+5 digits------series

40kHz/50kHz

RangeDisplay rangeAccuracy Le Accuracy De*Recommended equivalent mode
1H 400.0mH~999.9mH 2.0%+4 digits0.02parallel
400mH 40.00mH~399.99mH 0.8%+2 digits0.008parallel
40mH 4.000mH~39.999mH 0.8%+2 digits0.008------ 
4mH 400.0uH~3.9999mH 0.8%+2 digits0.008series
400uH40.00uH~399.99uH1.5%+3 digits0.015series
40uH0.000uH~39.999uH4.0%+5 digits------series

75KHz/100kHz

RangeDisplay rangeAccuracy Le Accuracy DeRecommended equivalent mode
100mH 40.00mH~399.99mH 2.5%+2 digits0.025parallel
40mH 4.000mH~39.999mH 1.5%+2 digits0.015parallel
4mH 400.0uH~3.9999mH 1.0%+2 digits0.01------ 
400uH40.00uH~399.99uH1.0%+2 digits0.01series
40uH4.000uH~39.999uH1.5%+5 digits0.015series
4uH0.000uH~3.999uH4%+10 digits------series

 Impedance Z and Phase Angle

100Hz/120Hz/400Hz/1kHz/10kHz

RangeDisplay rangeAccuracy ZeAccuracyRecommended equivalent mode
20MΩ4.000MΩ~20.000MΩ3.0%+10 digits3.4°parallel
4MΩ400.0kΩ~3.9999MΩ1.2%+3 digits0.7°parallel
400kΩ40.00kΩ~399.99kΩ0.3%+3 digits0.2°parallel
40kΩ4.000kΩ~39.999kΩ0.25%+2 digits0.1°------
4kΩ400.0Ω~3.9999kΩ0.25%+2 digits0.1°series
400Ω40.00Ω~399.99Ω0.25%+2 digits0.1°series
40Ω4.000Ω~39.999Ω0.5%+3 digits0.3°series
0.4000Ω~3.9999Ω2.0%+3 digits1.1°series
0.4Ω0.0000Ω~0.3999Ω4.0%+3 digits------series

40kHz/50KHz

RangeDisplay rangeAccuracy ZeAccuracyRecommended equivalent mode
20MΩ4.000MΩ~20.000MΩ7.0%+41 digits4.0°parallel
4MΩ400.0kΩ~3.9999MΩ2.5%+3 digits1.4°parallel
400kΩ40.00kΩ~399.99kΩ1.0%+4 digits0.6°parallel
40kΩ4.000kΩ~39.999kΩ1.0%+4 digits0.6°------
4kΩ400.0Ω~3.9999kΩ0.5%+3 digits0.3°series
400Ω40.00Ω~399.99Ω0.5%+3 digits0.3°series
40Ω4.000Ω~39.999Ω0.7%+4 digits0.4°series
0.4000Ω~3.9999Ω2.0%+6 digits1.1°series
0.4Ω0.0000Ω~0.3999Ω5.0%+10 digits------series

75KHz/100kHz

RangeDisplay rangeAccuracy ZeAccuracyRecommended equivalent mode
20MΩ4.000MΩ~20.000MΩ9.0%+20 digits5.2°parallel
4MΩ400.0kΩ~3.9999MΩ4.0%+10 digits2.3°parallel
400kΩ40.00kΩ~399.99kΩ1.5%+4 digits0.9°parallel
40kΩ4.000kΩ~39.999kΩ1.0%+2 digits0.6°parallel
4kΩ400.0Ω~3.9999kΩ0.7%+2 digits0.4°------
400Ω40.00Ω~399.99Ω0.7%+2 digits0.4°series
40Ω4.000Ω~39.999Ω1.0%+5 digits0.6°series
0.4000Ω~3.9999Ω3.0%+10 digits1.7°series
0.4Ω0.0000Ω~0.3999Ω7%+20 digits------series
- amazon_main_image: https://www.thedebugstore.com/images/product/lg-hantek-1832c-front.jpg - amazon_other_image_1: https://www.thedebugstore.com/images/product/lg-hantek-1832c-back.jpg - amazon_other_image_2: https://www.thedebugstore.com/images/product/lg-hantek-1832c-kit.jpg - amazon_other_image_3: https://www.thedebugstore.com/images/product/lg-hantek-1832c-display.jpg - amazon_other_image_4: https://www.thedebugstore.com/images/product/lg-hantek-1832c-display.jpg - amazon_browse_node: 428655031 - mpn: Hantek-1833C - backorder_label: If no stock is shown above, order now and we'll ship within 10 working days. - attachment_url_1: https://www.thedebugstore.com/files/attachments/13172/Hantek183X%20Series%20Manual_EN.pdf - attachment_title_1: User Manual: Hantek-1833C Handheld LCR Meter - google_product_category: 222 - attachments: [{"download_file":[{"download_file":"Hantek-1833C Handheld LCR Meter User Manual"}],"download_filetype":[{"download_filetype":"pdf"}]}] - condition: new - custom_product: false - mpn: Hantek-1833C - google_product_category: Electronics - custom_label_0: Meter - myordercount: {"ordercount":1,"recentcount":1} - badge: - widget:

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
R
Robin
Great for the price

Was worried that a cheap LCR meter might be a false economy
Very pleasantly surprised. Way better than expected
Accurate, very capable and easy to use

Thank you for the feedback, Robin. Hantek products are often underestimated and in the current economic climate, we all like a good deal.

- rating: {"scale_min":"1.0","scale_max":"5.0","value":"5.0"} - rating_count: 1 - warranty: 12 months - brand: Hantek - manufacturer: Hantek Electronic Co Ltd - brands: gid://shopify/Metaobject/56254759135 - breadcrumbs: ["gid://shopify/Collection/267180835005"] - review_snippet_widget:
- customhs_code: 903031 - detailed_description: {"type":"root","children":[{"type":"heading","level":2,"children":[{"type":"text","value":"Specifications"}]},{"type":"paragraph","children":[{"type":"text","value":"Model\nHantek-1832C\nHantek-1833C\nTest frequency\n100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz\n100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz\nAccuracy\n0.30%\nEquivalent Circuit\nSeries, Parallel\nTest level\n0.6Vrms\n0.6Vrms, 0.3Vrms\nMeasurement way\nManual, Auto\nDisplay screen\n2.8 inch TFT LCD\nMeasurement parameters\nPrinciple parameter: L/C/R/Z   Secondary parameter: X/D/Q/θ/ESR\nPrinciple parameter\nL/C/R/Z\nDeputy parameter\nX/D/Q/θ/ESR\nInductance Measurement range\n(L) 0-2000H\nCapacitance Measurement range\n(C) 0-20mF\nResistance  Measurement range\n(R) 0-20MΩ\nMeasurement Rate\nHigh spee d(4 times/s), Intermediate speed(twice/s) and Low speed(once/s)\nReset Function\nopen circuit calibration, short-circuit calibration\nTest Terminal Configuration\n3 terminal, 5 terminal\nCapacitance, C and Dissipation Factor, D\n100Hz/120Hz/400Hz\nRange\nDisplay range\nAccuracy Ce \nAccuracy De \nRecommended equivalent mode\n20mF \n4.000mF~20.000mF \n8.00%+5 digits\n0.08\nseries\n4mF \n400.0μF~3.9999mF \n2.00%+3 digits\n0.02\nseries\n400μF \n40.00μF~399.99μF \n0.60%+2 digits \n0.006\nseries\n40μF \n4.000μF~39.999μF \n0.40%+2 digits\n0.004\nseries\n4μF \n400.0nF~3.9999μF \n0.40%+2 digits\n0.004\n---- \n400nF \n40.00nF~399.99nF \n0.4%+2 digits\n0.004\nparallel\n40nF \n4.000nF~39.999nF \n0.5%+3 digits\n0.005\nparallel\n4nF \n0pF~3.999nF \n1.5%+5 digits \n------ \nparallel\n1KHz/4KHz\nRange\nDisplay range\nAccuracy Ce \nAccuracy De \nRecommended equivalent mode\n1000uF \n400.0uF~999.9uF \n3.00%+5 digits\n0.03\nseries\n400μF \n40.00μF~399.99μF \n1.50%+3 digits\n0.015\nseries\n40μF \n4.000μF~39.999μF \n0.60%+2 digits \n0.006\nseries\n4μF \n400.0nF~3.9999μF \n0.40%+2 digits\n0.004\n-----\n400nF \n40.00nF~399.99nF \n0.4%+2 digits\n0.004\nparallel\n40nF \n4.000nF~39.999nF \n0.6%+3 digits\n0.006\nparallel\n4nF \n400.0pF~3.9999nF \n0.6%+3 digits\n0.006\nparallel\n400pF\n0.0pF~399.9pF\n3%+5 digits\n------\nparallel\n10KHz\nRange\nDisplay range\nAccuracy Ce \nAccuracy De \nRecommended equivalent mode\n100μF \n40.00μF~100.00μF \n4.00%+5 digits \n0.04\nseries\n40μF \n4.000μF~39.999μF \n2.0%+3 digits\n0.02\nseries\n4μF \n400.0nF~3.9999μF \n0.60%+2 digits\n0.006\nseries\n400nF \n40.00nF~399.99nF \n0.4%+2 digits\n0.004\nseries\n40nF \n4.000nF~39.999nF \n0.4%+2 digits\n0.004\n------ \n4nF \n400.0pF~3.9999nF \n0.4%+2 digits\n0.004\nparallel\n400pF\n40.00pF~399.99pF\n0.6%+3 digits\n0.006\nparallel\n40pF\n0.00pF~39.99pF\n2.5%+5 digits\n------ \nparallel\n40KHz/50KHz\nRange\nDisplay range\nAccuracy Ce \nAccuracy De \nRecommended equivalent mode\n100μF \n40.00μF~100.00μF \n6.00%+5 digits\n0.06\nseries\n40μF \n4.000μF~39.999μF \n4.0%+3 digits \n0.04\nseries\n4μF \n400.0nF~3.9999μF \n1.0%+2 digits \n0.01\nseries\n400nF \n40.00nF~399.99nF \n0.6%+2 digits\n0.006\nseries\n40nF \n4.000nF~39.999nF \n0.6%+2 digits \n0.006\n------ \n4nF \n400.0pF~3.9999nF \n0.6%+2 digits \n0.006\nparallel\n400pF\n40.00pF~399.99pF\n1%+3 digits\n0.01\nparallel\n40pF\n0.000pF~39.999pF\n3%+5 digits\n------ \nparallel\n75KHz/100KHz\nRange\nDisplay range\nAccuracy Ce \nAccuracy De \nRecommended equivalent mode\n10μF \n4.000μF~10.000μF \n8.0%+20 digits\n0.08\nseries\n4μF \n400.0nF~3.9999μF \n5.0%+10 digits \n0.05\nseries\n400nF \n40.00nF~399.99nF \n1.5%+5 digits\n0.015\nseries\n40nF \n4.000nF~39.999nF \n1%+2 digits\n0.01\nseries\n4nF \n400.0pF~3.999nF \n1%+2 digits\n0.01\n------  \n400pF\n40.00pF~399.99pF\n1.5%+2 digits\n0.015\nparallel\n40pF\n4.000pF~39.999pF\n2%+5 digits\n0.02\nparallel\n4pF\n0.000pF~3.999pF\n5%+10 digits\n------ \nparallel\nInductance, L and Quality Factor, Q\n100Hz/120Hz/400Hz\nRange\nDisplay range\nAccuracy Le \nAccuracy De*\nRecommended equivalent mode\n1000H \n400.0H~999.9H \n2.00%+3 digits\n0.02\nparallel\n400H \n40.000H~399.99H \n0.60%+2 digits\n0.006\nparallel\n40H \n4.000H~39.999H \n0.40%+2 digits\n0.004\nparallel\n4H \n400.0mH~3.9999H \n0.40%+2 digits \n0.004\n---- \n400mH \n40.00mH~399.99mH \n0.4%+2 digits\n0.004\nseries\n40mH \n4.000mH~39.999mH \n0.6%+3 digits\n0.006\nseries\n4mH \n0uH~3.999mH \n3.0%+5 digits\n------ \nseries\n1kHz/4KHz\nRange\nDisplay range\nAccuracy Le \nAccuracy De*\nRecommended equivalent mode\n1H \n400.0mH~999.9mH \n1.50%+3 digits\n0.015\nparallel\n400mH \n40.00mH~399.99mH \n0.4%+2 digits\n0.004\nparallel\n40mH \n4.000mH~39.999mH \n0.4%+2 digits\n0.004\n------ \n4mH \n400.0uH~3.9999mH \n0.4%+2 digits\n0.004\nseries\n400uH\n40.00uH~399.99uH\n0.8%+3 digits\n0.008\nseries\n40uH\n0.00uH~39.99uH\n3.0%+5 digits\n------\nseries\n10KHz\nRange\nDisplay range\nAccuracy Le \nAccuracy De*\nRecommended equivalent mode\n100H \n40.00H~100.00H \n2.0%+3 digits \n0.02\nparallel\n40H \n4.000H~39.999H \n0.60%+2 digits\n0.006\nparallel\n4H \n400.0mH~3.9999H \n0.40%+2 digits \n0.004\nparallel\n400mH \n40.00mH~399.99mH \n0.4%+2 digits\n0.004\n------ \n40mH \n4.000mH~39.999mH \n0.4%+2 digits\n0.004\nseries\n4mH \n400.0uH~3.9999mH \n1%+3 digits\n0.01\nseries\n400uH\n0.0uH~399.9uH\n3.0%+5 digits\n------\nseries\n40kHz/50kHz\nRange\nDisplay range\nAccuracy Le \nAccuracy De*\nRecommended equivalent mode\n1H \n400.0mH~999.9mH \n2.0%+4 digits\n0.02\nparallel\n400mH \n40.00mH~399.99mH \n0.8%+2 digits\n0.008\nparallel\n40mH \n4.000mH~39.999mH \n0.8%+2 digits\n0.008\n------ \n4mH \n400.0uH~3.9999mH \n0.8%+2 digits\n0.008\nseries\n400uH\n40.00uH~399.99uH\n1.5%+3 digits\n0.015\nseries\n40uH\n0.000uH~39.999uH\n4.0%+5 digits\n------\nseries\n75KHz/100KHz\nRange\nDisplay range\nAccuracy Le \nAccuracy De\nRecommended equivalent mode\n100mH \n40.00mH~399.99mH \n2.5%+2 digits\n0.025\nparallel\n40mH \n4.000mH~39.999mH \n1.5%+2 digits\n0.015\nparallel\n4mH \n400.0uH~3.9999mH \n1.0%+2 digits\n0.01\n------ \n400uH\n40.00uH~399.99uH\n1.0%+2 digits\n0.01\nseries\n40uH\n4.000uH~39.999uH\n1.5%+5 digits\n0.015\nseries\n4uH\n0.000uH~3.999uH\n4%+10 digits\n------\nseries\n Impedance,  Z and Phase Angle, θ\n100Hz/120Hz/400Hz/1KHz/10KHz\nRange\nDisplay range\nAccuracy Ze\nAccuracy\nRecommended equivalent mode\n20MΩ\n4.000MΩ~20.000MΩ\n3.0%+10 digits\n3.4°\nparallel\n4MΩ\n400.0kΩ~3.9999MΩ\n1.2%+3 digits\n0.7°\nparallel\n400kΩ\n40.00kΩ~399.99kΩ\n0.3%+3 digits\n0.2°\nparallel\n40kΩ\n4.000kΩ~39.999kΩ\n0.25%+2 digits\n0.1°\n------\n4kΩ\n400.0Ω~3.9999kΩ\n0.25%+2 digits\n0.1°\nseries\n400Ω\n40.00Ω~399.99Ω\n0.25%+2 digits\n0.1°\nseries\n40Ω\n4.000Ω~39.999Ω\n0.5%+3 digits\n0.3°\nseries\n4Ω\n0.4000Ω~3.9999Ω\n2.0%+3 digits\n1.1°\nseries\n0.4Ω\n0.0000Ω~0.3999Ω\n4.0%+3 digits\n------\nseries\n40KHz/50KHz\nRange\nDisplay range\nAccuracy Ze\nAccuracy\nRecommended equivalent mode\n20MΩ\n4.000MΩ~20.000MΩ\n7.0%+41 digits\n4.0°\nparallel\n4MΩ\n400.0kΩ~3.9999MΩ\n2.5%+3 digits\n1.4°\nparallel\n400kΩ\n40.00kΩ~399.99kΩ\n1.0%+4 digits\n0.6°\nparallel\n40kΩ\n4.000kΩ~39.999kΩ\n1.0%+4 digits\n0.6°\n------\n4kΩ\n400.0Ω~3.9999kΩ\n0.5%+3 digits\n0.3°\nseries\n400Ω\n40.00Ω~399.99Ω\n0.5%+3 digits\n0.3°\nseries\n40Ω\n4.000Ω~39.999Ω\n0.7%+4 digits\n0.4°\nseries\n4Ω\n0.4000Ω~3.9999Ω\n2.0%+6 digits\n1.1°\nseries\n0.4Ω\n0.0000Ω~0.3999Ω\n5.0%+10 digits\n------\nseries\n75KHz/100KHz\nRange\nDisplay range\nAccuracy Ze\nAccuracy\nRecommended equivalent mode\n20MΩ\n4.000MΩ~20.000MΩ\n9.0%+20 digits\n5.2°\nparallel\n4MΩ\n400.0kΩ~3.9999MΩ\n4.0%+10 digits\n2.3°\nparallel\n400kΩ\n40.00kΩ~399.99kΩ\n1.5%+4 digits\n0.9°\nparallel\n40kΩ\n4.000kΩ~39.999kΩ\n1.0%+2 digits\n0.6°\nparallel\n4kΩ\n400.0Ω~3.9999kΩ\n0.7%+2 digits\n0.4°\n------\n400Ω\n40.00Ω~399.99Ω\n0.7%+2 digits\n0.4°\nseries\n40Ω\n4.000Ω~39.999Ω\n1.0%+5 digits\n0.6°\nseries\n4Ω\n0.4000Ω~3.9999Ω\n3.0%+10 digits\n1.7°\nseries\n0.4Ω\n0.0000Ω~0.3999Ω\n7%+20 digits\n------\nseries"}]}]} - key_feature_1: Handheld LCR meter with dual display, 10 test frequencies to 100 kHz, ESR/D/Q/θ, and 3/5-terminal guarded measurements. - key_feature_2: 100 kHz Test Frequency Coverage - key_feature_2_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Access up to 100 kHz test stimulus for measuring RF chokes, small MLCCs, and ferrites at operating frequencies, reducing extrapolation errors and improving correlation to in-circuit behaviour across prototypes, characterisation, and incoming inspection workflows in professional design and verification environments."}]}]} - key_feature_3: Ten Selectable Test Frequencies - key_feature_3_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Choose from ten discrete frequencies, including 100 Hz, 120 Hz, 1 kHz, 10 kHz, 40 kHz, 50 kHz, 75 kHz, and 100 kHz, to match vendor datasheet conditions, explore frequency response, and speed comparison testing without changing fixtures or configurations."}]}]} - key_feature_4: Dual Display On 2.8″ TFT - key_feature_4_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Primary and secondary parameters show together, for example C with D or ESR, so trends and trade-offs are visible immediately. The bright 2.8-inch TFT reduces misreads on the bench or production line and accelerates confident pass/fail decisions during fast sorting."}]}]} - key_feature_5: 0.3/0.6 Vrms Selectable Test Level - key_feature_5_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Select lower or higher excitation to avoid over-biasing sensitive dielectrics or activate non-linear behaviours when required. Matching test level to the device improves repeatability, aligns with datasheet conditions, and helps reproduce application environments accurately during detailed characterisation and robust validation."}]}]} - key_feature_6: 3- And 5-Terminal With Guard - key_feature_6_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Use three-terminal convenience for everyday SMD work or five-terminal measurements with guard to reduce leakage and stray capacitance. The switchable terminal scheme improves accuracy on high-impedance parts and enables reliable ESR and D measurements on small, lossy components consistently, repeatably."}]}]} - key_feature_7: Primary/Secondary Parameters Including ESR, D, Q, θ - key_feature_7_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"Measure L, C, R, and Z with secondary parameters X, D, Q, theta, and ESR displayed simultaneously. This exposes loss mechanisms, resonance behaviour, and parasitics critical for filter design, power stage stability analyses, compensation selection, and EMC-sensitive network characterisation insight."}]}]} - key_feature_8_tooltip: {"type":"root","children":[{"type":"paragraph","children":[{"type":"text","value":"USB connection and host software enable remote logging, limit testing, and report generation. Engineers can capture sweeps, archive evidence for compliance, integrate SCPI style commands, and standardise test setups across teams without additional dongles, paid licences, or manual transcription effort."}]}]} - key_feature_8: PC Software And Remote Control - why_people_choose_3_title: Better Fixturing Options - why_people_choose_2_title: See Losses Instantly - why_people_choose_1_title: Measure At Application Frequencies - why_people_choose_1: 100 kHz coverage with selectable 0.3/0.6 Vrms lets engineers characterise components at application frequency without bench instruments or awkward workarounds. - why_people_choose_3: Switchable three- and five-terminal measurement with guard improves accuracy on high-impedance parts, ensuring confident results with SMD capacitors and ferrites. - why_people_choose_2: Simultaneous L/C/R with ESR, D, Q, and theta on a 2.8-inch TFT speeds debug, sorting, and verification during development projects. - 1563428: What is the maximum test frequency on the Hantek-1833C?***SIMP***100 kHz. It also offers ten selectable frequencies so you can align with common datasheet test points or explore frequency response efficiently. - 1563429: Which parameters does the 1833C display?***SIMP***Primary L/C/R/Z plus secondary X, D (tan δ), Q, θ and ESR. Primary and secondary values can be shown together on the dual display. - 1563430: How does the 1833C differ from the 1832C?***SIMP***Both are from the 183X series; the 1833C adds higher test-frequency coverage (up to 100 kHz). Choose the 1832C if you don’t require 100 kHz. - 1563431: Does it support series and parallel equivalent circuit modes?***SIMP***Yes. You can select series or parallel to match the DUT and test frequency for representative results. - 1563432: Is there a guard terminal and 5-terminal measurement?***SIMP***Yes. The meter supports 3-terminal and 5-terminal with guard to reduce leakage and stray capacitance in high-impedance measurements. - 1563433: What test levels are available?***SIMP***0.3 Vrms and 0.6 Vrms, helping you avoid over-biasing sensitive dielectrics or intentionally excite non-linear behaviour when required. - 1563434: What measurement ranges are available?***SIMP***Up to 2000 H inductance, 20 mF capacitance and 20 MΩ resistance, covering most lab and production needs. - 1563435: Can I log data to a PC?***SIMP***Yes. USB “upper-computer” software enables remote control, limit testing and data logging for reports or incoming inspection. - 1563436: How does it compare to more expensive handhelds?***SIMP***Premium models (e.g., Keysight, B&K) add higher basic accuracy and ecosystems. The 1833C focuses on essential 100 kHz capability and guarded connections at a more accessible cost. - 1563437: What calibration features are provided?***SIMP***Open/short calibration routines are available to compensate fixtures and improve repeatability, especially for small SMD components. - summary:

The Hantek-1833C is a handheld LCR meter for characterising passive components across ten selectable test frequencies up to 100 kHz. A bright 2.8-inch TFT presents primary values (L/C/R/Z) together with secondary parameters (X, D, Q, θ, ESR) so you can see losses and reactance at a glance.

Engineers can choose 0.3 Vrms or 0.6 Vrms excitation, switch between series/parallel models, and run open/short calibration to maintain repeatability. For fixturing, the meter supports both 3-terminal and 5-terminal (with guard) connections to reduce leakage and stray capacitance on high-impedance parts. Measurement ranges span up to 2000 H, 20 mF and 20 MΩ with selectable speeds for binning or debug.

USB “upper-computer” software enables remote control and data logging for reports or incoming inspection. If you need lower maximum frequency, consider the related Hantek-1832C in the same series. For a broader view of impedance tools, see our Hantek LCR Meters collection.

If your workflow demands measurements at realistic operating frequencies with clear visibility of loss mechanisms, the 1833C provides the essentials in a compact, bench-friendly form factor.