# Title: Hantek-1833C 100 kHz Handheld LCR Meter ## Description: Specifications Model Hantek-1832C Hantek-1833C Test frequency 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz Accuracy 0.30% Equivalent Circuit Series, Parallel Test level 0.6Vrms 0.6Vrms, 0.3Vrms Measurement way Manual, Auto Display screen 2.8 inch TFT LCD Measurement parameters Principle parameter: L/C/R/Z Secondary parameter: X/D/Q/θ/ESR Principle parameter L/C/R/Z Deputy parameter X/D/Q/θ/ESR Inductance Measurement range (L) 0-2000H Capacitance Measurement range (C) 0-20mF Resistance Measurement range (R) 0-20MΩ Measurement Rate High spee d(4 times/s), Intermediate speed(twice/s) and Low speed(once/s) Reset Function open circuit calibration, short-circuit calibration Test Terminal Configuration 3 terminal, 5 terminal Capacitance, C and Dissipation Factor, D 100Hz/120Hz/400Hz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 20mF 4.000mF~20.000mF 8.00%+5 digits 0.08 series 4mF 400.0μF~3.9999mF 2.00%+3 digits 0.02 series 400μF 40.00μF~399.99μF 0.60%+2 digits 0.006 series 40μF 4.000μF~39.999μF 0.40%+2 digits 0.004 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ---- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.5%+3 digits 0.005 parallel 4nF 0pF~3.999nF 1.5%+5 digits ------ parallel 1KHz/4KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 1000uF 400.0uF~999.9uF 3.00%+5 digits 0.03 series 400μF 40.00μF~399.99μF 1.50%+3 digits 0.015 series 40μF 4.000μF~39.999μF 0.60%+2 digits 0.006 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ----- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.6%+3 digits 0.006 parallel 4nF 400.0pF~3.9999nF 0.6%+3 digits 0.006 parallel 400pF 0.0pF~399.9pF 3%+5 digits ------ parallel 10KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 4.00%+5 digits 0.04 series 40μF 4.000μF~39.999μF 2.0%+3 digits 0.02 series 4μF 400.0nF~3.9999μF 0.60%+2 digits 0.006 series 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 series 40nF 4.000nF~39.999nF 0.4%+2 digits 0.004 ------ 4nF 400.0pF~3.9999nF 0.4%+2 digits 0.004 parallel 400pF 40.00pF~399.99pF 0.6%+3 digits 0.006 parallel 40pF 0.00pF~39.99pF 2.5%+5 digits ------ parallel 40KHz/50KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 6.00%+5 digits 0.06 series 40μF 4.000μF~39.999μF 4.0%+3 digits 0.04 series 4μF 400.0nF~3.9999μF 1.0%+2 digits 0.01 series 400nF 40.00nF~399.99nF 0.6%+2 digits 0.006 series 40nF 4.000nF~39.999nF 0.6%+2 digits 0.006 ------ 4nF 400.0pF~3.9999nF 0.6%+2 digits 0.006 parallel 400pF 40.00pF~399.99pF 1%+3 digits 0.01 parallel 40pF 0.000pF~39.999pF 3%+5 digits ------ parallel 75KHz/100KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 10μF 4.000μF~10.000μF 8.0%+20 digits 0.08 series 4μF 400.0nF~3.9999μF 5.0%+10 digits 0.05 series 400nF 40.00nF~399.99nF 1.5%+5 digits 0.015 series 40nF 4.000nF~39.999nF 1%+2 digits 0.01 series 4nF 400.0pF~3.999nF 1%+2 digits 0.01 ------ 400pF 40.00pF~399.99pF 1.5%+2 digits 0.015 parallel 40pF 4.000pF~39.999pF 2%+5 digits 0.02 parallel 4pF 0.000pF~3.999pF 5%+10 digits ------ parallel Inductance, L and Quality Factor, Q 100Hz/120Hz/400Hz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1000H 400.0H~999.9H 2.00%+3 digits 0.02 parallel 400H 40.000H~399.99H 0.60%+2 digits 0.006 parallel 40H 4.000H~39.999H 0.40%+2 digits 0.004 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 ---- 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 series 40mH 4.000mH~39.999mH 0.6%+3 digits 0.006 series 4mH 0uH~3.999mH 3.0%+5 digits ------ series 1kHz/4KHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 1.50%+3 digits 0.015 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 parallel 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 ------ 4mH 400.0uH~3.9999mH 0.4%+2 digits 0.004 series 400uH 40.00uH~399.99uH 0.8%+3 digits 0.008 series 40uH 0.00uH~39.99uH 3.0%+5 digits ------ series 10KHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 100H 40.00H~100.00H 2.0%+3 digits 0.02 parallel 40H 4.000H~39.999H 0.60%+2 digits 0.006 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 ------ 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 series 4mH 400.0uH~3.9999mH 1%+3 digits 0.01 series 400uH 0.0uH~399.9uH 3.0%+5 digits ------ series 40kHz/50kHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 2.0%+4 digits 0.02 parallel 400mH 40.00mH~399.99mH 0.8%+2 digits 0.008 parallel 40mH 4.000mH~39.999mH 0.8%+2 digits 0.008 ------ 4mH 400.0uH~3.9999mH 0.8%+2 digits 0.008 series 400uH 40.00uH~399.99uH 1.5%+3 digits 0.015 series 40uH 0.000uH~39.999uH 4.0%+5 digits ------ series 75KHz/100KHz Range Display range Accuracy Le Accuracy De Recommended equivalent mode 100mH 40.00mH~399.99mH 2.5%+2 digits 0.025 parallel 40mH 4.000mH~39.999mH 1.5%+2 digits 0.015 parallel 4mH 400.0uH~3.9999mH 1.0%+2 digits 0.01 ------ 400uH 40.00uH~399.99uH 1.0%+2 digits 0.01 series 40uH 4.000uH~39.999uH 1.5%+5 digits 0.015 series 4uH 0.000uH~3.999uH 4%+10 digits ------ series Impedance, Z and Phase Angle, θ 100Hz/120Hz/400Hz/1KHz/10KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 3.0%+10 digits 3.4° parallel 4MΩ 400.0kΩ~3.9999MΩ 1.2%+3 digits 0.7° parallel 400kΩ 40.00kΩ~399.99kΩ 0.3%+3 digits 0.2° parallel 40kΩ 4.000kΩ~39.999kΩ 0.25%+2 digits 0.1° ------ 4kΩ 400.0Ω~3.9999kΩ 0.25%+2 digits 0.1° series 400Ω 40.00Ω~399.99Ω 0.25%+2 digits 0.1° series 40Ω 4.000Ω~39.999Ω 0.5%+3 digits 0.3° series 4Ω 0.4000Ω~3.9999Ω 2.0%+3 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 4.0%+3 digits ------ series 40KHz/50KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 7.0%+41 digits 4.0° parallel 4MΩ 400.0kΩ~3.9999MΩ 2.5%+3 digits 1.4° parallel 400kΩ 40.00kΩ~399.99kΩ 1.0%+4 digits 0.6° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+4 digits 0.6° ------ 4kΩ 400.0Ω~3.9999kΩ 0.5%+3 digits 0.3° series 400Ω 40.00Ω~399.99Ω 0.5%+3 digits 0.3° series 40Ω 4.000Ω~39.999Ω 0.7%+4 digits 0.4° series 4Ω 0.4000Ω~3.9999Ω 2.0%+6 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 5.0%+10 digits ------ series 75KHz/100KHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 9.0%+20 digits 5.2° parallel 4MΩ 400.0kΩ~3.9999MΩ 4.0%+10 digits 2.3° parallel 400kΩ 40.00kΩ~399.99kΩ 1.5%+4 digits 0.9° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+2 digits 0.6° parallel 4kΩ 400.0Ω~3.9999kΩ 0.7%+2 digits 0.4° ------ 400Ω 40.00Ω~399.99Ω 0.7%+2 digits 0.4° series 40Ω 4.000Ω~39.999Ω 1.0%+5 digits 0.6° series 4Ω 0.4000Ω~3.9999Ω 3.0%+10 digits 1.7° series 0.4Ω 0.0000Ω~0.3999Ω 7%+20 digits ------ series ## Product type: Meter ## Vendor: Hantek Electronic Co Ltd ## Tags: Capacitance, Device, Handheld Oscilloscope, Hantek, hantek-electronic-co-ltd, hantekInductance, Inductance, LCR, Meter, Resistance ## Price range: 190.0 - 190.0 GBP ## Link: https://thedebugstore.com/products/hantek-1833c-100khz-handheld-lcr-meter-1833c ## Options - Title: Default Title ## Collections - [New Products](https://thedebugstore.com/a/llms/collections/new-products-debug-store) - [Hantek Electronic Co. Ltd](https://thedebugstore.com/a/llms/collections/hantek-electronic-catalogue) - [Admin: No Inventory](https://thedebugstore.com/a/llms/collections/no-inventory) - [Test Meters](https://thedebugstore.com/a/llms/collections/test-meters-catalogue) - [Test & Measurement](https://thedebugstore.com/a/llms/collections/test-measurement-catalogue) - [LCR Meters](https://thedebugstore.com/a/llms/collections/lcr-meters-catalogue) - [Resistance Meters](https://thedebugstore.com/a/llms/collections/resistance-meter-catalogue) - [Hantek Handheld Oscilloscope](https://thedebugstore.com/a/llms/collections/hantek-handheld-oscilloscopes) - [Hantek LCR Meters](https://thedebugstore.com/a/llms/collections/hantek-lcr-meters-catalogue) - [Capacitance Meters](https://thedebugstore.com/a/llms/collections/capacitance-meters-catalogue) - [Inductance Meters](https://thedebugstore.com/a/llms/collections/inductance-meters-catalogue) ## Variants - Default Title, SKU: Hantek-1833C, Available: yes, Inventory: 0 ## Metafields - full_description:
| Model | Hantek-1832C | Hantek-1833C | ||
| Test frequency |
100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz |
100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz |
||
| Accuracy | 0.30% | |||
| Equivalent Circuit | Series, Parallel | |||
| Test level | 0.6Vrms | 0.6Vrms, 0.3Vrms | ||
| Measurement way | Manual, Auto | |||
| Display screen | 2.8 inch TFT LCD | |||
| Measurement parameters | Principle parameter: L/C/R/Z Secondary parameter: X/D/Q/θ/ESR | |||
| Principle parameter | L/C/R/Z | |||
| Deputy parameter | X/D/Q/θ/ESR | |||
| Inductance Measurement range | (L) 0-2000H | |||
| Capacitance Measurement range | (C) 0-20mF | |||
| Resistance Measurement range | (R) 0-20MΩ | |||
| Measurement Rate | High spee d(4 times/s), Intermediate speed(twice/s) and Low speed(once/s) | |||
| Reset Function | open circuit calibration, short-circuit calibration | |||
| Test Terminal Configuration | 3 terminal, 5 terminal | |||
Capacitance, C and Dissipation Factor, D |
||||
100Hz/120Hz/400Hz |
||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 20mF | 4.000mF~20.000mF | 8.00%+5 digits | 0.08 | series |
| 4mF | 400.0μF~3.9999mF | 2.00%+3 digits | 0.02 | series |
| 400μF | 40.00μF~399.99μF | 0.60%+2 digits | 0.006 | series |
| 40μF | 4.000μF~39.999μF | 0.40%+2 digits | 0.004 | series |
| 4μF | 400.0nF~3.9999μF | 0.40%+2 digits | 0.004 | ---- |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | parallel |
| 40nF | 4.000nF~39.999nF | 0.5%+3 digits | 0.005 | parallel |
| 4nF | 0pF~3.999nF | 1.5%+5 digits | ------ | parallel |
1KHz/4KHz |
||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 1000uF | 400.0uF~999.9uF | 3.00%+5 digits | 0.03 | series |
| 400μF | 40.00μF~399.99μF | 1.50%+3 digits | 0.015 | series |
| 40μF | 4.000μF~39.999μF | 0.60%+2 digits | 0.006 | series |
| 4μF | 400.0nF~3.9999μF | 0.40%+2 digits | 0.004 | ----- |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | parallel |
| 40nF | 4.000nF~39.999nF | 0.6%+3 digits | 0.006 | parallel |
| 4nF | 400.0pF~3.9999nF | 0.6%+3 digits | 0.006 | parallel |
| 400pF | 0.0pF~399.9pF | 3%+5 digits | ------ | parallel |
10KHz |
||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 100μF | 40.00μF~100.00μF | 4.00%+5 digits | 0.04 | series |
| 40μF | 4.000μF~39.999μF | 2.0%+3 digits | 0.02 | series |
| 4μF | 400.0nF~3.9999μF | 0.60%+2 digits | 0.006 | series |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | series |
| 40nF | 4.000nF~39.999nF | 0.4%+2 digits | 0.004 | ------ |
| 4nF | 400.0pF~3.9999nF | 0.4%+2 digits | 0.004 | parallel |
| 400pF | 40.00pF~399.99pF | 0.6%+3 digits | 0.006 | parallel |
| 40pF | 0.00pF~39.99pF | 2.5%+5 digits | ------ | parallel |
40KHz/50KHz |
||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 100μF | 40.00μF~100.00μF | 6.00%+5 digits | 0.06 | series |
| 40μF | 4.000μF~39.999μF | 4.0%+3 digits | 0.04 | series |
| 4μF | 400.0nF~3.9999μF | 1.0%+2 digits | 0.01 | series |
| 400nF | 40.00nF~399.99nF | 0.6%+2 digits | 0.006 | series |
| 40nF | 4.000nF~39.999nF | 0.6%+2 digits | 0.006 | ------ |
| 4nF | 400.0pF~3.9999nF | 0.6%+2 digits | 0.006 | parallel |
| 400pF | 40.00pF~399.99pF | 1%+3 digits | 0.01 | parallel |
| 40pF | 0.000pF~39.999pF | 3%+5 digits | ------ | parallel |
75KHz/100KHz |
||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 10μF | 4.000μF~10.000μF | 8.0%+20 digits | 0.08 | series |
| 4μF | 400.0nF~3.9999μF | 5.0%+10 digits | 0.05 | series |
| 400nF | 40.00nF~399.99nF | 1.5%+5 digits | 0.015 | series |
| 40nF | 4.000nF~39.999nF | 1%+2 digits | 0.01 | series |
| 4nF | 400.0pF~3.999nF | 1%+2 digits | 0.01 | ------ |
| 400pF | 40.00pF~399.99pF | 1.5%+2 digits | 0.015 | parallel |
| 40pF | 4.000pF~39.999pF | 2%+5 digits | 0.02 | parallel |
| 4pF | 0.000pF~3.999pF | 5%+10 digits | ------ | parallel |
Inductance, L and Quality Factor, Q |
||||
100Hz/120Hz/400Hz |
||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1000H | 400.0H~999.9H | 2.00%+3 digits | 0.02 | parallel |
| 400H | 40.000H~399.99H | 0.60%+2 digits | 0.006 | parallel |
| 40H | 4.000H~39.999H | 0.40%+2 digits | 0.004 | parallel |
| 4H | 400.0mH~3.9999H | 0.40%+2 digits | 0.004 | ---- |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | series |
| 40mH | 4.000mH~39.999mH | 0.6%+3 digits | 0.006 | series |
| 4mH | 0uH~3.999mH | 3.0%+5 digits | ------ | series |
1kHz/4KHz |
||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1H | 400.0mH~999.9mH | 1.50%+3 digits | 0.015 | parallel |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | parallel |
| 40mH | 4.000mH~39.999mH | 0.4%+2 digits | 0.004 | ------ |
| 4mH | 400.0uH~3.9999mH | 0.4%+2 digits | 0.004 | series |
| 400uH | 40.00uH~399.99uH | 0.8%+3 digits | 0.008 | series |
| 40uH | 0.00uH~39.99uH | 3.0%+5 digits | ------ | series |
10KHz |
||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 100H | 40.00H~100.00H | 2.0%+3 digits | 0.02 | parallel |
| 40H | 4.000H~39.999H | 0.60%+2 digits | 0.006 | parallel |
| 4H | 400.0mH~3.9999H | 0.40%+2 digits | 0.004 | parallel |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | ------ |
| 40mH | 4.000mH~39.999mH | 0.4%+2 digits | 0.004 | series |
| 4mH | 400.0uH~3.9999mH | 1%+3 digits | 0.01 | series |
| 400uH | 0.0uH~399.9uH | 3.0%+5 digits | ------ | series |
40kHz/50kHz |
||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1H | 400.0mH~999.9mH | 2.0%+4 digits | 0.02 | parallel |
| 400mH | 40.00mH~399.99mH | 0.8%+2 digits | 0.008 | parallel |
| 40mH | 4.000mH~39.999mH | 0.8%+2 digits | 0.008 | ------ |
| 4mH | 400.0uH~3.9999mH | 0.8%+2 digits | 0.008 | series |
| 400uH | 40.00uH~399.99uH | 1.5%+3 digits | 0.015 | series |
| 40uH | 0.000uH~39.999uH | 4.0%+5 digits | ------ | series |
75KHz/100KHz |
||||
| Range | Display range | Accuracy Le | Accuracy De | Recommended equivalent mode |
| 100mH | 40.00mH~399.99mH | 2.5%+2 digits | 0.025 | parallel |
| 40mH | 4.000mH~39.999mH | 1.5%+2 digits | 0.015 | parallel |
| 4mH | 400.0uH~3.9999mH | 1.0%+2 digits | 0.01 | ------ |
| 400uH | 40.00uH~399.99uH | 1.0%+2 digits | 0.01 | series |
| 40uH | 4.000uH~39.999uH | 1.5%+5 digits | 0.015 | series |
| 4uH | 0.000uH~3.999uH | 4%+10 digits | ------ | series |
Impedance, Z and Phase Angle, θ |
||||
100Hz/120Hz/400Hz/1KHz/10KHz |
||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 3.0%+10 digits | 3.4° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 1.2%+3 digits | 0.7° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 0.3%+3 digits | 0.2° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 0.25%+2 digits | 0.1° | ------ |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.25%+2 digits | 0.1° | series |
| 400Ω | 40.00Ω~399.99Ω | 0.25%+2 digits | 0.1° | series |
| 40Ω | 4.000Ω~39.999Ω | 0.5%+3 digits | 0.3° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 2.0%+3 digits | 1.1° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 4.0%+3 digits | ------ | series |
40KHz/50KHz |
||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 7.0%+41 digits | 4.0° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 2.5%+3 digits | 1.4° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 1.0%+4 digits | 0.6° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 1.0%+4 digits | 0.6° | ------ |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.5%+3 digits | 0.3° | series |
| 400Ω | 40.00Ω~399.99Ω | 0.5%+3 digits | 0.3° | series |
| 40Ω | 4.000Ω~39.999Ω | 0.7%+4 digits | 0.4° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 2.0%+6 digits | 1.1° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 5.0%+10 digits | ------ | series |
75KHz/100KHz |
||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 9.0%+20 digits | 5.2° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 4.0%+10 digits | 2.3° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 1.5%+4 digits | 0.9° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 1.0%+2 digits | 0.6° | parallel |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.7%+2 digits | 0.4° | ------ |
| 400Ω | 40.00Ω~399.99Ω | 0.7%+2 digits | 0.4° | series |
| 40Ω | 4.000Ω~39.999Ω | 1.0%+5 digits | 0.6° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 3.0%+10 digits | 1.7° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 7%+20 digits | ------ | series |
| Model | Hantek-1832C | Hantek-1833C | ||
| Test frequency | 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz | 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz | ||
| Accuracy | 0.30% | |||
| Equivalent Circuit | series, parallel | |||
| Test level | 0.6Vrms | 0.6Vrms, 0.3Vrms | ||
| Measurement way | manual, auto | |||
| Display screen | 2.8 inch TFT LCD | |||
| Measurement parameters | principle parameter: L/C/R/Z deputy parameter: X/D/Q/θ/ESR | |||
| Principle parameter | L/C/R/Z | |||
| Deputy parameter | X/D/Q/θ/ESR | |||
| Inductance Measurement range | (L) 0-2000H | |||
| Capacitance Measurement range | (C) 0-20mF | |||
| Resistance Measurement range | (R) 0-20MΩ | |||
| Measurement speed | high speed(4 times/s), intermediate speed(twice/s), low speed(once/s) | |||
| Reset function | open circuit calibration, short-circuit calibration | |||
| Test terminal configuration | 3 terminal, 5 terminal | |||
| Includes | standard with 1.USB Type-C data cable; 2.power adapter; 3.short circuit card; 4.red and black rubber plug; 5.large capacity lithium battery | |||
Capacitance C and dissipation - D | ||||
100Hz/120Hz/400Hz | ||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 20mF | 4.000mF~20.000mF | 8.00%+5 digits | 0.08 | series |
| 4mF | 400.0μF~3.9999mF | 2.00%+3 digits | 0.02 | series |
| 400μF | 40.00μF~399.99μF | 0.60%+2 digits | 0.006 | series |
| 40μF | 4.000μF~39.999μF | 0.40%+2 digits | 0.004 | series |
| 4μF | 400.0nF~3.9999μF | 0.40%+2 digits | 0.004 | ---- |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | parallel |
| 40nF | 4.000nF~39.999nF | 0.5%+3 digits | 0.005 | parallel |
| 4nF | 0pF~3.999nF | 1.5%+5 digits | ------ | parallel |
1KHz/4kHz | ||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 1000uF | 400.0uF~999.9uF | 3.00%+5 digits | 0.03 | series |
| 400μF | 40.00μF~399.99μF | 1.50%+3 digits | 0.015 | series |
| 40μF | 4.000μF~39.999μF | 0.60%+2 digits | 0.006 | series |
| 4μF | 400.0nF~3.9999μF | 0.40%+2 digits | 0.004 | ----- |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | parallel |
| 40nF | 4.000nF~39.999nF | 0.6%+3 digits | 0.006 | parallel |
| 4nF | 400.0pF~3.9999nF | 0.6%+3 digits | 0.006 | parallel |
| 400pF | 0.0pF~399.9pF | 3%+5 digits | ------ | parallel |
10KHz | ||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 100μF | 40.00μF~100.00μF | 4.00%+5 digits | 0.04 | series |
| 40μF | 4.000μF~39.999μF | 2.0%+3 digits | 0.02 | series |
| 4μF | 400.0nF~3.9999μF | 0.60%+2 digits | 0.006 | series |
| 400nF | 40.00nF~399.99nF | 0.4%+2 digits | 0.004 | series |
| 40nF | 4.000nF~39.999nF | 0.4%+2 digits | 0.004 | ------ |
| 4nF | 400.0pF~3.9999nF | 0.4%+2 digits | 0.004 | parallel |
| 400pF | 40.00pF~399.99pF | 0.6%+3 digits | 0.006 | parallel |
| 40pF | 0.00pF~39.99pF | 2.5%+5 digits | ------ | parallel |
40KHz/50KHz | ||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 100μF | 40.00μF~100.00μF | 6.00%+5 digits | 0.06 | series |
| 40μF | 4.000μF~39.999μF | 4.0%+3 digits | 0.04 | series |
| 4μF | 400.0nF~3.9999μF | 1.0%+2 digits | 0.01 | series |
| 400nF | 40.00nF~399.99nF | 0.6%+2 digits | 0.006 | series |
| 40nF | 4.000nF~39.999nF | 0.6%+2 digits | 0.006 | ------ |
| 4nF | 400.0pF~3.9999nF | 0.6%+2 digits | 0.006 | parallel |
| 400pF | 40.00pF~399.99pF | 1%+3 digits | 0.01 | parallel |
| 40pF | 0.000pF~39.999pF | 3%+5 digits | ------ | parallel |
75KHz/100KHz | ||||
| Range | Display range | Accuracy Ce | Accuracy De | Recommended equivalent mode |
| 10μF | 4.000μF~10.000μF | 8.0%+20 digits | 0.08 | series |
| 4μF | 400.0nF~3.9999μF | 5.0%+10 digits | 0.05 | series |
| 400nF | 40.00nF~399.99nF | 1.5%+5 digits | 0.015 | series |
| 40nF | 4.000nF~39.999nF | 1%+2 digits | 0.01 | series |
| 4nF | 400.0pF~3.999nF | 1%+2 digits | 0.01 | ------ |
| 400pF | 40.00pF~399.99pF | 1.5%+2 digits | 0.015 | parallel |
| 40pF | 4.000pF~39.999pF | 2%+5 digits | 0.02 | parallel |
| 4pF | 0.000pF~3.999pF | 5%+10 digits | ------ | parallel |
Inductance L and quality factor | ||||
100Hz/120Hz/400Hz | ||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1000H | 400.0H~999.9H | 2.00%+3 digits | 0.02 | parallel |
| 400H | 40.000H~399.99H | 0.60%+2 digits | 0.006 | parallel |
| 40H | 4.000H~39.999H | 0.40%+2 digits | 0.004 | parallel |
| 4H | 400.0mH~3.9999H | 0.40%+2 digits | 0.004 | ---- |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | series |
| 40mH | 4.000mH~39.999mH | 0.6%+3 digits | 0.006 | series |
| 4mH | 0uH~3.999mH | 3.0%+5 digits | ------ | series |
1kHz/4KHz | ||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1H | 400.0mH~999.9mH | 1.50%+3 digits | 0.015 | parallel |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | parallel |
| 40mH | 4.000mH~39.999mH | 0.4%+2 digits | 0.004 | ------ |
| 4mH | 400.0uH~3.9999mH | 0.4%+2 digits | 0.004 | series |
| 400uH | 40.00uH~399.99uH | 0.8%+3 digits | 0.008 | series |
| 40uH | 0.00uH~39.99uH | 3.0%+5 digits | ------ | series |
10kHz | ||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 100H | 40.00H~100.00H | 2.0%+3 digits | 0.02 | parallel |
| 40H | 4.000H~39.999H | 0.60%+2 digits | 0.006 | parallel |
| 4H | 400.0mH~3.9999H | 0.40%+2 digits | 0.004 | parallel |
| 400mH | 40.00mH~399.99mH | 0.4%+2 digits | 0.004 | ------ |
| 40mH | 4.000mH~39.999mH | 0.4%+2 digits | 0.004 | series |
| 4mH | 400.0uH~3.9999mH | 1%+3 digits | 0.01 | series |
| 400uH | 0.0uH~399.9uH | 3.0%+5 digits | ------ | series |
40kHz/50kHz | ||||
| Range | Display range | Accuracy Le | Accuracy De* | Recommended equivalent mode |
| 1H | 400.0mH~999.9mH | 2.0%+4 digits | 0.02 | parallel |
| 400mH | 40.00mH~399.99mH | 0.8%+2 digits | 0.008 | parallel |
| 40mH | 4.000mH~39.999mH | 0.8%+2 digits | 0.008 | ------ |
| 4mH | 400.0uH~3.9999mH | 0.8%+2 digits | 0.008 | series |
| 400uH | 40.00uH~399.99uH | 1.5%+3 digits | 0.015 | series |
| 40uH | 0.000uH~39.999uH | 4.0%+5 digits | ------ | series |
75KHz/100kHz | ||||
| Range | Display range | Accuracy Le | Accuracy De | Recommended equivalent mode |
| 100mH | 40.00mH~399.99mH | 2.5%+2 digits | 0.025 | parallel |
| 40mH | 4.000mH~39.999mH | 1.5%+2 digits | 0.015 | parallel |
| 4mH | 400.0uH~3.9999mH | 1.0%+2 digits | 0.01 | ------ |
| 400uH | 40.00uH~399.99uH | 1.0%+2 digits | 0.01 | series |
| 40uH | 4.000uH~39.999uH | 1.5%+5 digits | 0.015 | series |
| 4uH | 0.000uH~3.999uH | 4%+10 digits | ------ | series |
Impedance Z and Phase Angle | ||||
100Hz/120Hz/400Hz/1kHz/10kHz | ||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 3.0%+10 digits | 3.4° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 1.2%+3 digits | 0.7° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 0.3%+3 digits | 0.2° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 0.25%+2 digits | 0.1° | ------ |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.25%+2 digits | 0.1° | series |
| 400Ω | 40.00Ω~399.99Ω | 0.25%+2 digits | 0.1° | series |
| 40Ω | 4.000Ω~39.999Ω | 0.5%+3 digits | 0.3° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 2.0%+3 digits | 1.1° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 4.0%+3 digits | ------ | series |
40kHz/50KHz | ||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 7.0%+41 digits | 4.0° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 2.5%+3 digits | 1.4° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 1.0%+4 digits | 0.6° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 1.0%+4 digits | 0.6° | ------ |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.5%+3 digits | 0.3° | series |
| 400Ω | 40.00Ω~399.99Ω | 0.5%+3 digits | 0.3° | series |
| 40Ω | 4.000Ω~39.999Ω | 0.7%+4 digits | 0.4° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 2.0%+6 digits | 1.1° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 5.0%+10 digits | ------ | series |
75KHz/100kHz | ||||
| Range | Display range | Accuracy Ze | Accuracy | Recommended equivalent mode |
| 20MΩ | 4.000MΩ~20.000MΩ | 9.0%+20 digits | 5.2° | parallel |
| 4MΩ | 400.0kΩ~3.9999MΩ | 4.0%+10 digits | 2.3° | parallel |
| 400kΩ | 40.00kΩ~399.99kΩ | 1.5%+4 digits | 0.9° | parallel |
| 40kΩ | 4.000kΩ~39.999kΩ | 1.0%+2 digits | 0.6° | parallel |
| 4kΩ | 400.0Ω~3.9999kΩ | 0.7%+2 digits | 0.4° | ------ |
| 400Ω | 40.00Ω~399.99Ω | 0.7%+2 digits | 0.4° | series |
| 40Ω | 4.000Ω~39.999Ω | 1.0%+5 digits | 0.6° | series |
| 4Ω | 0.4000Ω~3.9999Ω | 3.0%+10 digits | 1.7° | series |
| 0.4Ω | 0.0000Ω~0.3999Ω | 7%+20 digits | ------ | series |
Was worried that a cheap LCR meter might be a false economy
Very pleasantly surprised. Way better than expected
Accurate, very capable and easy to use
Thank you for the feedback, Robin. Hantek products are often underestimated and in the current economic climate, we all like a good deal.
The Hantek-1833C is a handheld LCR meter for characterising passive components across ten selectable test frequencies up to 100 kHz. A bright 2.8-inch TFT presents primary values (L/C/R/Z) together with secondary parameters (X, D, Q, θ, ESR) so you can see losses and reactance at a glance.
Engineers can choose 0.3 Vrms or 0.6 Vrms excitation, switch between series/parallel models, and run open/short calibration to maintain repeatability. For fixturing, the meter supports both 3-terminal and 5-terminal (with guard) connections to reduce leakage and stray capacitance on high-impedance parts. Measurement ranges span up to 2000 H, 20 mF and 20 MΩ with selectable speeds for binning or debug.
USB “upper-computer” software enables remote control and data logging for reports or incoming inspection. If you need lower maximum frequency, consider the related Hantek-1832C in the same series. For a broader view of impedance tools, see our Hantek LCR Meters collection.
If your workflow demands measurements at realistic operating frequencies with clear visibility of loss mechanisms, the 1833C provides the essentials in a compact, bench-friendly form factor.